Compressed sensing with gradient total variation for low-dose CBCT reconstruction

被引:3
|
作者
Seo, Chang-Woo [1 ]
Cha, Bo Kyung [2 ]
Jeon, Seongchae [2 ]
Huh, Young [2 ]
Park, Justin C. [3 ]
Lee, Byeonghun [4 ]
Baek, Junghee [5 ]
Kim, Eunyoung [5 ]
机构
[1] Yonsei Univ, Coll Hlth Sci, Dept Radiat Convergence Engn, Wonju, South Korea
[2] Korea Electrotechnol Res Inst, Adv Med Device Res Ctr, Ansan, South Korea
[3] Univ Florida, Dept Radiat Oncol, Gainesville, FL USA
[4] Inha Univ, Sch Informat & Commun Engn, Inchon, South Korea
[5] Soongsil Univ, Sch Global Media, Seoul, South Korea
关键词
Iterative reconstruction; Compressed sensing; Total variation; Gradient total variation; Low-dose; CBCT; BEAM COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; ALGORITHMS; DETECTOR; CT;
D O I
10.1016/j.nima.2014.12.106
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes the improvement of convergence speed with gradient total variation (GTV) in compressed sensing (CS) for low-dose cone-beam computed tomography (CBCT) reconstruction. We derive a fast algorithm for the constrained total variation (TV)-based a minimum number of noisy projections. To achieve this task we combine the GTV with a TV-norm regularization term to promote an accelerated sparsity in the X-ray attenuation characteristics of the human body. The GTV is derived from a TV and enforces more efficient computationally and faster in convergence until a desired solution is achieved. The numerical algorithm is simple and derives relatively fast convergence. We apply a gradient projection algorithm that seeks a solution iteratively in the direction of the projected gradient while enforcing a non-negatively of the found solution. In comparison with the Feldkamp, Davis, and Kress (FDK) and conventional TV algorithms, the proposed GTV algorithm showed convergence in <= 18 iterations, whereas the original TV algorithm needs at least 34 iterations in reducing 50% of the projections compared with the FDK algorithm in order to reconstruct the chest phantom images. Future investigation includes improving imaging quality, particularly regarding X-ray cone-beam scatter, and motion artifacts of CBCT reconstruction. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:570 / 573
页数:4
相关论文
共 50 条
  • [11] Low-dose CBCT reconstruction via joint non-local total variation denoising and cubic B-spline interpolation
    Ho Lee
    Jiyoung Park
    Yeonho Choi
    Kyung Ran Park
    Byung Jun Min
    Ik Jae Lee
    [J]. Scientific Reports, 11
  • [12] Experimental study on the application of a compressed-sensing (CS) algorithm to dental cone-beam CT (CBCT) for accurate, low-dose image reconstruction
    Jieun Oh
    Hyosung Cho
    Uikyu Je
    Minsik Lee
    Hyojeong Kim
    Daeki Hong
    Yeonok Park
    Seonhwa Lee
    Heemoon Cho
    Sungil Choi
    Yangseo Koo
    [J]. Journal of the Korean Physical Society, 2013, 62 : 834 - 838
  • [13] Discriminative Prior - Prior Image Constrained Compressed Sensing Reconstruction for Low-Dose CT Imaging
    Yang Chen
    Jin Liu
    Lizhe Xie
    Yining Hu
    Huazhong Shu
    Limin Luo
    Libo Zhang
    Zhiguo Gui
    Gouenou Coatrieux
    [J]. Scientific Reports, 7
  • [14] Experimental study on the application of a compressed-sensing (CS) algorithm to dental cone-beam CT (CBCT) for accurate, low-dose image reconstruction
    Oh, Jieun
    Cho, Hyosung
    Je, Uikyu
    Lee, Minsik
    Kim, Hyojeong
    Hong, Daeki
    Park, Yeonok
    Lee, Seonhwa
    Cho, Heemoon
    Choi, Sungil
    Koo, Yangseo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (05) : 834 - 838
  • [15] Discriminative Prior - Prior Image Constrained Compressed Sensing Reconstruction for Low-Dose CT Imaging
    Chen, Yang
    Liu, Jin
    Xie, Lizhe
    Hu, Yining
    Shu, Huazhong
    Luo, Limin
    Zhang, Libo
    Gui, Zhiguo
    Coatrieux, Gouenou
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [16] SECOND ORDER TOTAL GENERALIZED VARIATION FOR LOW-DOSE COMPUTED TOMOGRAPHY IMAGE RECONSTRUCTION
    Niu, Shanzhou
    Ma, Jianhua
    Huang, Jing
    Bian, Zhaoying
    Liang, Zhengrong
    Chen, Wufan
    [J]. 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 173 - 176
  • [17] Low-dose CT reconstruction via edge-preserving total variation regularization
    Tian, Zhen
    Jia, Xun
    Yuan, Kehong
    Pan, Tinsu
    Jiang, Steve B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18): : 5949 - 5967
  • [18] A comparison study of total variation stokes strategy for low-dose CT image reconstruction
    Liu, Yan
    Lu, Hongbing
    Wang, Ke
    Zhang, Hao
    Moore, William
    Liang, Zhengrong
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [19] Image Compressed Sensing Reconstruction Based on Structural Group Total Variation
    Zhao Hui
    Yang Xiaojun
    Zhang Jing
    Sun Chao
    Zang Tianqi
    [J]. JOURNAL OF ELECTRONICS & INFORMATION TECHNOLOGY, 2020, 42 (11) : 2773 - 2780
  • [20] Compressed Sensing with a First-Order Method for Low-Dose Cone-Beam CT Reconstruction
    Choi, K.
    Wang, J.
    Zhu, L.
    Suh, T.
    Boyd, S.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3442 - +