Test of radiation detectors used in homeland security applications

被引:3
|
作者
Pibida, L [1 ]
Minniti, R [1 ]
O'Brien, A [1 ]
Unterweger, A [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
来源
HEALTH PHYSICS | 2005年 / 88卷 / 05期
关键词
operational topic; detector; radiation; safety standards; radiation protection;
D O I
10.1097/01.HP.0000156062.92296.38
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work was performed as part of the National Institute of Standards and Technology (NIST) program to support the development of the new American National Standards Institute (ANSI) standards N42.32-2003 and N42.33-2003 for handheld detectors, and personal electronic dosimeters, as well as to support the Office of Law Enforcement Standards (OLES) and the Department of Homeland Security (DHS) in testing these types of detectors for their use by first responders. These instruments are required to operate over a photon energy range of 60 keV to 1.33 MeV and over a wide range of air-kerma rates. The performance and response of various radiation detectors, purchased by the NIST, was recorded when placed in Co-60, Cs-137, and x-ray beams at different air-kerma rates. The measurements described in this report were performed at the NIST x-ray and gamma-ray radiation calibration facilities. The instruments' response (exposure or dose rate readings) shows strong energy dependence but almost no dependence to different air-kerma rates. The data here reported provide a benchmark in support of current protocols that are being developed for radiation detection instrumentation used in homeland security applications. A future plan is to test these devices, plus other commercially available detectors, against ANSI standards N42.32-2003 and N42.33-2003.
引用
收藏
页码:S84 / S90
页数:7
相关论文
共 50 条
  • [31] Wireless sensors and sensor networks for homeland security applications
    Potyrailo, Radislav A.
    Nagraj, Nandini
    Surman, Cheryl
    Boudries, Hacene
    Lai, Hanh
    Slocik, Joseph M.
    Kelley-Loughnane, Nancy
    Naik, Rajesh R.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 40 : 133 - 145
  • [32] Bioterrorism: Mathematical modeling applications in homeland security.
    Lev, B
    INTERFACES, 2005, 35 (06) : 531 - 532
  • [33] The Evolution of Neutron Straw Detector Applications in Homeland Security
    Lacy, Jeffrey L.
    Athanasiades, Athanasios
    Martin, Christopher S.
    Sun, Liang
    Vazquez-Flores, Gerson L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 1140 - 1146
  • [34] Computer vision and pattern recognition in homeland security applications
    Garibotto, Giovanni B.
    Applications of Fuzzy Sets Theory, 2007, 4578 : 335 - 341
  • [35] Radiation Detectors Scintillator-Photodiode on the Base of A2B6 Crystals for Application in Homeland Security and Medical Equipment
    Grinyov, B. V.
    Ryzhikov, V. D.
    Naydenov, S. V.
    Smith, C. F.
    Opolonin, A. D.
    Lisetskaya, E. K.
    Shumeiko, N. A.
    Kurna, N. L.
    Onischenko, G. M.
    Tretyak, S. E.
    Galkin, S. N.
    Voronkin, E. F.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1134 - 1138
  • [36] Replacement of 3He in Constrained-Volume Homeland Security Detectors
    Lacy, Jeffrey L.
    Athanasiades, Athanasios
    Martin, Christopher S.
    Sun, Liang
    Vazquez-Flores, Gerson J.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 324 - 325
  • [37] The impact of the Department of Homeland Security (DHS) on radiation detection instrumentation
    Cox, MC
    HEALTH PHYSICS, 2005, 89 (01): : S58 - S58
  • [38] Homeland security
    Yen, J
    Popp, R
    IEEE INTELLIGENT SYSTEMS, 2005, 20 (05) : 76 - 76
  • [39] Homeland Security
    Friedmann, Robert R.
    INTERNATIONAL CRIMINAL JUSTICE REVIEW, 2007, 17 (04) : 336 - 339
  • [40] 'Homeland security'
    Brock, Geoffrey
    POETRY, 2007, 190 (02) : 106 - 107