Test of radiation detectors used in homeland security applications

被引:3
|
作者
Pibida, L [1 ]
Minniti, R [1 ]
O'Brien, A [1 ]
Unterweger, A [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
来源
HEALTH PHYSICS | 2005年 / 88卷 / 05期
关键词
operational topic; detector; radiation; safety standards; radiation protection;
D O I
10.1097/01.HP.0000156062.92296.38
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work was performed as part of the National Institute of Standards and Technology (NIST) program to support the development of the new American National Standards Institute (ANSI) standards N42.32-2003 and N42.33-2003 for handheld detectors, and personal electronic dosimeters, as well as to support the Office of Law Enforcement Standards (OLES) and the Department of Homeland Security (DHS) in testing these types of detectors for their use by first responders. These instruments are required to operate over a photon energy range of 60 keV to 1.33 MeV and over a wide range of air-kerma rates. The performance and response of various radiation detectors, purchased by the NIST, was recorded when placed in Co-60, Cs-137, and x-ray beams at different air-kerma rates. The measurements described in this report were performed at the NIST x-ray and gamma-ray radiation calibration facilities. The instruments' response (exposure or dose rate readings) shows strong energy dependence but almost no dependence to different air-kerma rates. The data here reported provide a benchmark in support of current protocols that are being developed for radiation detection instrumentation used in homeland security applications. A future plan is to test these devices, plus other commercially available detectors, against ANSI standards N42.32-2003 and N42.33-2003.
引用
收藏
页码:S84 / S90
页数:7
相关论文
共 50 条
  • [21] Fast Neutron Detection in Homeland Security Applications
    Chandra, Rico
    Davatz, Giovanna
    Gendotti, Ulisse
    Howard, Alexander
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 508 - 511
  • [22] Homeland security: Operations research initiatives and applications
    Lowe, James K.
    INTERFACES, 2006, 36 (06) : 483 - 485
  • [23] Sensor Placement for Urban Homeland Security Applications
    Hamel, David
    Chwastek, Matthew
    Garcia, Saturnino
    Farouk, Bakhtier
    Kam, Moshe
    Dandekar, Kapil R.
    INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2010,
  • [24] Wireless structural monitoring for homeland security applications
    Kiremidjian, GK
    Kiremidjian, A
    Lynch, JP
    NONDESTRUCTIVE DETECTION AND MEASUREMENT FOR HOMELAND SECURITY II, 2004, 5395 : 82 - 90
  • [25] High-Performance, Large-Volume THM CdZnTe Detectors for Medical Imaging and Homeland Security Applications
    Chen, Henry
    Awadalla, Salah A.
    Redden, Robert
    Bindley, Glenn
    Bolotnikov, A. E.
    Carini, Camarda G.
    James, R. B.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3629 - 3637
  • [26] Update on Radio Frequency Radiation; Standards and Homeland Security
    Leonowich, JA
    HEALTH PHYSICS, 2005, 89 (01): : S38 - S38
  • [27] A survey of operations research models and applications in homeland security
    Wright, P. Daniel
    Liberatore, Matthew J.
    Nydick, Robert L.
    INTERFACES, 2006, 36 (06) : 514 - 529
  • [28] Potential applications of SMART Layer® technology for Homeland Security
    Kumar, A
    Wu, F
    Lin, M
    Beard, SJ
    Qing, XL
    Zhang, C
    Hamilton, M
    Ikegami, R
    NONDESTRUCTIVE DETECTION AND MEASUREMENT FOR HOMELAND SECURITY II, 2004, 5395 : 61 - 69
  • [29] Utilizing the IEEE 802.16 standard for homeland security applications
    Rathgeb, B
    Cheng, Q
    Unattended Ground Sensor Technologies and Applications VII, 2005, 5796 : 203 - 213
  • [30] Universal Explosive Detection System for Homeland Security Applications
    Lee, Vincent Y.
    Bromberg, Edward E. A.
    NEXT-GENERATION SPECTROSCOPIC TECHNOLOGIES III, 2010, 7680