Improved indoor air temperature and humidity control using a novel direct-expansion-based air conditioning system

被引:12
|
作者
Yang, Liu [1 ]
Deng, Shiming [1 ]
Fang, Guanyu [1 ]
Li, Weilin [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
[2] Zhengzhou Univ, Sch Civil Engn, Sci Ave 100, Zhengzhou 450001, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2021年 / 43卷
关键词
Direct expansion; Air conditioning; Two sectioned cooling coil; Controllability test; Humidity control; OPERATIONAL CHARACTERISTICS; CAPACITY CONTROLLER; CONTROL ALGORITHMS; PERFORMANCE; EQUIPMENT;
D O I
10.1016/j.jobe.2021.102920
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many approaches have been tried to obtain an improved indoor thermal environment in small-to medium-sized buildings located in hot-humid climates when using direct-expansion (DX)-based air conditioning (A/C) systems. However, inadequacies still existed in these approaches. Therefore, to address these problems, a novel DX-based A/C system with a two sectioned cooling coil (TS-DXAC) has been proposed. In this paper, a control strategy to operate the TS-DXAC system for achieving an improved indoor air temperature and humidity control in hot and humid climates is presented. Firstly, the detailed configurations of the TS-DXAC system and the control strategy of the TS-DXAC system are presented. The developed strategy included two control algorithms, i.e., Algorithm I and Algorithm II, enabling the TS-DXAC system to be operated under two different indoor conditions, i.e., hot-humid, and hot-dry, respectively. Secondly, a test TS-DXAC system was set up and the controllability tests for the control strategy were carried out. This is followed by presenting the experimental results and related discussions. The experimental results demonstrated that in all the tests, indoor air temperature could be directly controlled at the two indoor conditions, while indoor air temperature and relative humidity could be simultaneously controlled over a relatively long period at a hot-humid indoor condition using Algorithm I. The control strategy enabled the TS-DXAC system to respond the changes in either indoor settings or cooling loads by outputting variable sensible and latent cooling capacities at a higher energy efficiency compared to conventional On-Off controlled DX A/C systems. However, to improve the control sensitivity under Algorithm I, consideration should be given to the variable speed operation of the compressor in the TS-DXAC system.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Temperature and humidity control with a model predictive control method in the air-conditioning system
    Liu Jingyun
    Li Ping
    2017 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS), 2017, : 408 - 412
  • [32] A Thermal Comfort based Controller for a Direct Expansion Air Conditioning System
    Yan, Huaxia
    Niu, Jiajia
    Deng, Shiming
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1817 - 1822
  • [33] Modeling Validation and Control Analysis for Controlled Temperature and Humidity of Air Conditioning System
    Lee, Jing-Nang
    Lin, Tsung-Min
    Chen, Chien-Chih
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [34] Research of Temperature and Humidity Decoupling Control for Central Air-conditioning System
    Zhao, Xianmei
    Tang, Jie
    Chen, Dongxian
    2009 INTERNATIONAL CONFERENCE ON INTELLIGENT HUMAN-MACHINE SYSTEMS AND CYBERNETICS, VOL 2, PROCEEDINGS, 2009, : 404 - 408
  • [35] Simulation analysis of temperature/humidity independent control air conditioning system with exhaust air heat recovery
    Han, Zong-Wei
    Zhao, Jing
    Ding, Hui-Ting
    Na, Wei
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2012, 33 (11): : 1649 - 1653
  • [36] Dynamic modeling and control of a direct expansion air conditioning system using artificial neural network
    Li, Ning
    Xia, Liang
    Deng Shiming
    Xu, Xiangguo
    Chan, Ming-Yin
    APPLIED ENERGY, 2012, 91 (01) : 290 - 300
  • [37] INDOOR TEMPERATURE CONTROL AND ENERGY SAVING POTENTIAL OF AN AIR CONDITIONING SYSTEM USING PD CONTROLLER
    Nasution, Henry
    Aziz, Azhar Abdul
    Dahlan, Afiq Aiman
    Zulkifli, Amirah Haziqah
    Sumeru
    JURNAL TEKNOLOGI, 2015, 76 (11): : 63 - 67
  • [38] Online model for indoor temperature control based on building thermal process of air conditioning system
    Li, Xiuming
    Han, Zongwei
    Zhao, Tianyi
    Gao, Jiajia
    Journal of Building Engineering, 2021, 39
  • [39] Online model for indoor temperature control based on building thermal process of air conditioning system
    Li, Xiuming
    Han, Zongwei
    Zhao, Tianyi
    Gao, Jiajia
    JOURNAL OF BUILDING ENGINEERING, 2021, 39
  • [40] A control-oriented hybrid model for a direct expansion air conditioning system
    Xu, Xiangguo
    Huang, Zhiyuan
    Wang, Xiaofei
    Zhong, Ziwen
    Zhang, Xiaobo
    ENERGY AND BUILDINGS, 2017, 155 : 76 - 87