Simultaneous Head and Spine MR Imaging in Children Using a Dedicated Multichannel Receiver System at 3T

被引:4
|
作者
Li, Nan [1 ,2 ,3 ]
Zheng, Hui [5 ]
Xu, Guangzu [6 ]
Gui, Ting [5 ]
Yin, Qiufeng [5 ]
Chen, Qiaoyan [1 ,2 ]
Lee, Jo [1 ,2 ]
Xin, Yang [6 ]
Zhang, Shuheng [6 ]
He, Qiang [6 ]
Zhang, Xiaoliang [7 ]
Liu, Xin [1 ,2 ]
Zheng, Hairong [1 ,2 ]
Wang, Dengbin [5 ]
Li, Ye [1 ,4 ]
机构
[1] Chinese Acad Sci, Lauterbur Imaging Res Ctr, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Key Lab Magnet Resonance & Multimodal Imaging Gua, Shenzhen, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] Univ Chinese Acad Sci, Key Lab Magnet Resonance & Multimodal Imaging Gua, Beijing 100049, Peoples R China
[5] Shanghai Jiao Tong Univ, Xinhua Hosp, Dept Radiol, Sch Med, Shanghai 200092, Peoples R China
[6] Shanghai United Imaging Healthcare, Shanghai, Peoples R China
[7] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY USA
基金
国家重点研发计划;
关键词
Head; Magnetic resonance imaging; Radio frequency; Signal to noise ratio; Pediatrics; Magnetic heads; Image segmentation; Pediatrics imaging; head and spine MR imaging; SNR; resolution; radiofrequency (RF) coil; WHOLE-BODY MRI; PHASED-ARRAY; PERFORMANCE; CHALLENGES; SENSITIVITY; BRAIN;
D O I
10.1109/TBME.2021.3082149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The purpose of this work was to enable simultaneous head and spine Magnetic Resonance imaging (MRI) in children at 3T by using a dedicated multichannel radiofrequency coil array system. Methods: A 24-channel head and spine pediatric coil system was developed and constructed. The coil's performance was compared with a commercially available 24-channel adult head-neck coil and a spine coil (1-4 spine of 16-channel were selected). Signal-to-noise ratio (SNR) and parallel imaging capability were quantitatively evaluated by phantom studies and in vivo imaging experiments. With Institutional Review Board and Ethics Committee approval, the designed coil was used to acquire head and spine images on 27 children in clinical settings. Results: The pediatric coil provided substantial SNR improvements with an increase of 32% to 40% in the brain region and up to a two-fold increase in the surface. SNR increased by at least 18% in the spine region. The coil enabled higher resolution and a faster imaging speed, owing to significantly improved SNR. Extensive coverage of the coil enabled high-quality fast imaging from head-neck to the whole spine. Good image quality with an average score 4.63 out of 5 was achieved using the developed pediatric coil in clinical studies. Conclusion: Simultaneous head and spine MRI with superior performance have been successfully acquired in children subjects at 3T using the dedicated 24-channel head and spine pediatric coil system. Significance: The 24-channel pediatric coil system potentially can enhance pediatric head and spine MRI in clinical research and diagnosis.
引用
收藏
页码:3659 / 3670
页数:12
相关论文
共 50 条
  • [31] Evaluation of dedicated PET/MR breast coil in integrated PET/MR system for simultaneous PET/MR breast imaging
    Cho, Ihn Ho
    Kong, Eun-jung
    Chun, KyunghAh
    Jeong, Ju Hye
    Kwon, SangDon
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [32] Simultaneous multi-slice MR imaging of the hip at 3T to reduce acquisition times and maintain image quality
    Haraikawa, Mayuko
    Suzuki, Masashi
    Inoue, Kaiji
    Kozawa, Eito
    Tanaka, Junji
    Niitsu, Mamoru
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [33] Saturation Recovery Myocardial T1 Mapping with a Composite Radiofrequency Pulse on a 3T MR Imaging System
    Morita, Kosuke
    Oda, Seitaro
    Utsunomiya, Daisuke
    Nakaura, Takeshi
    Matsubara, Takatoshi
    Goto, Makoto
    Okuaki, Tomoyuki
    Yuki, Hideaki
    Nagayama, Yasunori
    Kidoh, Masafumi
    Hirata, Kenichiro
    Iyama, Yuij
    Taguchi, Narumi
    Hatemura, Masahiro
    Hashida, Masahiro
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (01) : 35 - 41
  • [34] High resolution carotid black-blood 3T MR with parallel imaging and dedicated 4-channel surface coils
    Saam, Tobias
    Raya, Jose G.
    Cyran, Clemens C.
    Bochmann, Katja
    Meimarakis, Georgios
    Dietrich, Olaf
    Clevert, Dirk A.
    Frey, Ute
    Yuan, Chun
    Hatsukami, Thomas S.
    Werf, Abe
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2009, 11
  • [35] High resolution carotid black-blood 3T MR with parallel imaging and dedicated 4-channel surface coils
    Tobias Saam
    Jose G Raya
    Clemens C Cyran
    Katja Bochmann
    Georgios Meimarakis
    Olaf Dietrich
    Dirk A Clevert
    Ute Frey
    Chun Yuan
    Thomas S Hatsukami
    Abe Werf
    Maximilian F Reiser
    Konstantin Nikolaou
    Journal of Cardiovascular Magnetic Resonance, 11
  • [36] Unaliasing lipid contamination for MR spectroscopic imaging of gliomas at 3T using sensitivity encoding (SENSE)
    Ozturk-Isik, E
    Crane, JC
    Cha, SM
    Chang, SM
    Berger, MS
    Nelson, SJ
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 1164 - 1169
  • [37] MR Imaging Near Metallic Implants Using MAVRIC SL: Initial Clinical Experience at 3T
    Gutierrez, Luis B.
    Do, Bao H.
    Gold, Garry E.
    Hargreaves, Brian A.
    Koch, Kevin M.
    Worters, Pauline W.
    Stevens, Kathryn J.
    ACADEMIC RADIOLOGY, 2015, 22 (03) : 370 - 379
  • [38] Imaging characteristics in Parkinson's disease and atypical parkinsonian syndromes using 3T MR siderotractography
    Borgohain, R.
    Rammohan, V.
    Kandadai, R. M.
    Jabeen, S. A.
    Kanikannan, M. A.
    MOVEMENT DISORDERS, 2009, 24 : S183 - S183
  • [39] Monitoring Fractional Anisotropy in Developing Rabbit Brain Using MR Diffusion Tensor Imaging at 3T
    Jao, Jo-Chi
    Yang, Yu-Ting
    Hsiao, Chia-Chi
    Chen, Po-Chou
    MEDICAL IMAGING 2016-BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2016, 9788
  • [40] MR Imaging of Lymph Nodes using Gadofluorine M: Feasibility in a Swine Model at 1.5 and 3T
    Spuentrup, E.
    Ruhl, K.
    Weigl, S.
    Misselwitz, B.
    Wardeh, D.
    Buhl, A.
    Botnar, R. M.
    Katoh, M.
    Wiethoff, A. J.
    Guenther, R. W.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (08): : 698 - 705