Simultaneous Head and Spine MR Imaging in Children Using a Dedicated Multichannel Receiver System at 3T

被引:4
|
作者
Li, Nan [1 ,2 ,3 ]
Zheng, Hui [5 ]
Xu, Guangzu [6 ]
Gui, Ting [5 ]
Yin, Qiufeng [5 ]
Chen, Qiaoyan [1 ,2 ]
Lee, Jo [1 ,2 ]
Xin, Yang [6 ]
Zhang, Shuheng [6 ]
He, Qiang [6 ]
Zhang, Xiaoliang [7 ]
Liu, Xin [1 ,2 ]
Zheng, Hairong [1 ,2 ]
Wang, Dengbin [5 ]
Li, Ye [1 ,4 ]
机构
[1] Chinese Acad Sci, Lauterbur Imaging Res Ctr, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Key Lab Magnet Resonance & Multimodal Imaging Gua, Shenzhen, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] Univ Chinese Acad Sci, Key Lab Magnet Resonance & Multimodal Imaging Gua, Beijing 100049, Peoples R China
[5] Shanghai Jiao Tong Univ, Xinhua Hosp, Dept Radiol, Sch Med, Shanghai 200092, Peoples R China
[6] Shanghai United Imaging Healthcare, Shanghai, Peoples R China
[7] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY USA
基金
国家重点研发计划;
关键词
Head; Magnetic resonance imaging; Radio frequency; Signal to noise ratio; Pediatrics; Magnetic heads; Image segmentation; Pediatrics imaging; head and spine MR imaging; SNR; resolution; radiofrequency (RF) coil; WHOLE-BODY MRI; PHASED-ARRAY; PERFORMANCE; CHALLENGES; SENSITIVITY; BRAIN;
D O I
10.1109/TBME.2021.3082149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The purpose of this work was to enable simultaneous head and spine Magnetic Resonance imaging (MRI) in children at 3T by using a dedicated multichannel radiofrequency coil array system. Methods: A 24-channel head and spine pediatric coil system was developed and constructed. The coil's performance was compared with a commercially available 24-channel adult head-neck coil and a spine coil (1-4 spine of 16-channel were selected). Signal-to-noise ratio (SNR) and parallel imaging capability were quantitatively evaluated by phantom studies and in vivo imaging experiments. With Institutional Review Board and Ethics Committee approval, the designed coil was used to acquire head and spine images on 27 children in clinical settings. Results: The pediatric coil provided substantial SNR improvements with an increase of 32% to 40% in the brain region and up to a two-fold increase in the surface. SNR increased by at least 18% in the spine region. The coil enabled higher resolution and a faster imaging speed, owing to significantly improved SNR. Extensive coverage of the coil enabled high-quality fast imaging from head-neck to the whole spine. Good image quality with an average score 4.63 out of 5 was achieved using the developed pediatric coil in clinical studies. Conclusion: Simultaneous head and spine MRI with superior performance have been successfully acquired in children subjects at 3T using the dedicated 24-channel head and spine pediatric coil system. Significance: The 24-channel pediatric coil system potentially can enhance pediatric head and spine MRI in clinical research and diagnosis.
引用
收藏
页码:3659 / 3670
页数:12
相关论文
共 50 条
  • [21] An MR technique for simultaneous quantitative imaging of water content, conductivity and susceptibility, with application to brain tumours using a 3T hybrid MR-PET scanner
    Yupeng Liao
    Ana-Maria Oros-Peusquens
    Johannes Lindemeyer
    Nazim Lechea
    Carolin Weiß -Lucas
    Karl-Josef Langen
    N. Jon Shah
    Scientific Reports, 9
  • [22] Direct visualization of the human subthalamic nucleus with 3T MR imaging
    Slavin, KV
    Thulborn, KR
    Wess, C
    Nersesyan, H
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (01) : 80 - 84
  • [23] 3T Diffusion Weighted MR Imaging in Diagnosing Extrahepatic Cholangiocarcinoma
    Yang, Xiaoping
    Ren, Ke
    Sun, Wenge
    Qi, Xixun
    Wang, Yongfeng
    Chu, Jingang
    Xu, Ke
    CURRENT MEDICAL IMAGING REVIEWS, 2017, 13 (04) : 406 - 412
  • [24] A comparison of 3T MR imaging of the prostate with and without an endorectal coil
    Ischia, J.
    Co, S.
    Harris, A.
    Kozlowski, P.
    Jones, E.
    Chang, S.
    Goldenberg, L.
    BJU INTERNATIONAL, 2014, 113 : 119 - 120
  • [25] The Julich Experience With Simultaneous 3T MR-BrainPET: Methods and Technology
    Caldeira, Liliana
    Kops, Elena Rota
    Yun, Seong Dae
    Da Silva, Nuno
    Mauler, Joerg
    Weirich, Christoph
    Scheins, Juergen
    Herzog, Hans
    Tellmann, Lutz
    Lohmann, Philipp
    Langen, Karl-Josef
    Lerche, Christoph
    Shah, N. Jon
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (03) : 352 - 362
  • [26] Advantages and pitfalls in 3T MR brain imaging:: A pictorial review
    Schmitz, BL
    Aschoff, AJ
    Hoffmann, MHK
    Grön, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (09) : 2229 - 2237
  • [27] 3T neonatal brain and body imaging in a MR compatible incubator
    de Lange, Charlotte
    Nedregaard, Bard
    Lang, Astri
    ACTA RADIOLOGICA, 2013, 54 (04) : 11 - 11
  • [28] Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System
    Tajima, Shunsuke
    Isoda, Haruo
    Fukunaga, Masaki
    Komori, Yoshiaki
    Naganawa, Shinji
    Sadato, Norihiro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2025, 24 (01) : 88 - 102
  • [29] Lymphedema Evaluation Using Noninvasive 3T MR Lymphangiography
    Crescenzi, Rachelle
    Donahue, Paula M. C.
    Hartley, Katherine G.
    Desai, Aditi A.
    Scott, Allison O.
    Braxton, Vaughn
    Mahany, Helen
    Lants, Sarah K.
    Donahue, Manus J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (05) : 1349 - 1360
  • [30] Chemical Shift Imaging in the Head and Neck at 3T: Initial Results
    Yeung, David K. W.
    Fong, Kwan-Ying
    Chan, Queenie C. C.
    King, Ann D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (05) : 1248 - 1254