Qualitative Evaluation of Platelet Concentrates Prepared with Different Methods

被引:0
|
作者
Varshashree [1 ]
Das, Subhashis [1 ]
Prabhakar, K. [2 ]
机构
[1] Sridevaraj Urs Med Coll, Dept Pathol, Kolar 563101, Karnataka, India
[2] Sridevaraj Urs Med Coll, Dept Med, Kolar, Karnataka, India
关键词
Apheresis; Buffy coat; Whole blood; BUFFY-COAT; TRANSFUSION; APHERESIS;
D O I
10.7860/JCDR/2021/47715.15558
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: One of the most important responsibility of Blood Bank is to ensure uninterrupted supply of quality blood products, namely Platelet Concentrate (PC), which are in high demand particularly during pandemic. In India, PCs are of three types prepared by different methods like Platelet Rich Plasma-Platelet Concentrate (PRP-PC), Buffy Coat Platelet Concentrates (BC-PC), and Single Donor Platelets units (SDP). Hence, establishing optimum quality standards across all the three types of PC remains a challenge in order to maximum benefit to recipients. Aim: To assess and compare the quality parameters of platelet concentrate prepared by PRP, BC-PC and apheresis methods Materials and Methods: Laboratory based observational study done at rural, tertiary care, post graduate, teaching hospital located at south India from December 2018 to November 2019. A total of 156 PCs were studied with 52 units belonging to PRP method, 52units BC-PC method and the remaining were 52 units of SDP prepared by apheresis method. Quality parameters studied include volume, pH, swirling, White Blood Cell count (WBC count/bag), platelet count/bag and platelet indices. Platelet indices include Mean Platelet Volume (MPV), Platelet distribution width (PDW), and Platelet Large Cell Ratio (PLCR). Arterial Blood Gas (ABG) analysis was also done to assess (pH, pCO(2), pHCO(3-)). The p-value less than 0.05 were considered statistically significant. Statistical Package for the Social Sciences (SPSS) software version 23.0 used for statistical analysis. Results: All the 156 PC units were analysed as per the Director General of Health Services (DGHS) India, criteria. A score of 5 was obtained for 58 out of 156 cases for SDP, 56 out of 156 cases for BC-PC, 42 out of 156 cases for PRP-PC units with respective percentage of 37.1%, 33.3% and 26.9%, respectively. All the PC units were sterile and Red Blood Cell (RBC) contamination was within acceptable limits. Conclusion: In this study, quality parameters of SDP was better than BC-PC and PRP-PC but with improvement and more standardisation of procedures and storage, BC-PC units can give a yield similar to that of SDP units.
引用
收藏
页码:EC29 / EC33
页数:5
相关论文
共 50 条
  • [31] Comparison of platelet concentrates from pooled buffy coats prepared automatically by the OrbiSac system and conventionally produced platelet concentrates
    Schallmoser, K
    Rosskopf, K
    Macher, S
    Stubenrauch, M
    Lanzer, G
    TRANSFUSION, 2005, 45 (03) : 67A - 68A
  • [32] Platelet products prepared by different methods of sedimentation undergo platelet activation differently during storage
    Skripchenko, Andrey
    Kurtz, James
    Moroff, Gary
    Wagner, Stephen J.
    TRANSFUSION, 2008, 48 (07) : 1469 - 1477
  • [33] Evaluation of the efficacy of platelet transfusions obtained with different methods
    Tardivel, R.
    Vasse, J.
    Bois, S.
    Regnault, T.
    Semana, G.
    TRANSFUSION, 2008, 48 (02) : 151A - 151A
  • [34] Evaluation of Platelet Count by Different Methods in Hyperlipidemia Specimens
    Dou, Min
    Cao, Peng-Ju
    CLINICAL LABORATORY, 2022, 68 (04) : 755 - 762
  • [35] Evaluation of actarit/γ-cyclodextrin complex prepared by different methods
    Yutaka Inoue
    Shota Watanabe
    Rina Suzuki
    Isamu Murata
    Ikuo Kanamoto
    Journal of Inclusion Phenomena and Macrocyclic Chemistry, 2015, 81 : 161 - 168
  • [36] Evaluation of actarit/γ-cyclodextrin complex prepared by different methods
    Inoue, Yutaka
    Watanabe, Shota
    Suzuki, Rina
    Murata, Isamu
    Kanamoto, Ikuo
    JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2015, 81 (1-2) : 161 - 168
  • [37] THE USE OF MEAN PLATELET VOLUME FOR EVALUATION OF QUALITY OF PLATELET CONCENTRATES
    BROZOVIC, B
    SEGHATCHIAN, MJ
    MCSHINE, RL
    BLOOD COAGULATION & FIBRINOLYSIS, 1992, 3 (05) : 629 - 631
  • [38] LIPID-COMPOSITION OF FRESHLY PREPARED AND STORED PLATELET CONCENTRATES
    HAMID, MA
    KUNICKI, TJ
    ASTER, RH
    BLOOD, 1980, 55 (01) : 124 - 130
  • [39] CLINICAL EFFECTIVENESS OF PLATELET CONCENTRATES PREPARED WITH OR WITHOUT ACIDIFICATION OF PLASMA
    CAVINS, JA
    PIRNAR, A
    ROY, AJ
    FARBER, S
    TRANSFUSION, 1968, 8 (05) : 289 - &
  • [40] POOLED PLATELET CONCENTRATES PREPARED IN A NEW BLOOD BANK CENTRIFUGE
    MILLER, WV
    GILLEM, HG
    YANKEE, RA
    SCHMIDT, PJ
    TRANSFUSION, 1969, 9 (05) : 251 - &