The effect of blockage and tunnel slope on smoke spread and ceiling temperature distribution in a natural-ventilated metro depot

被引:24
|
作者
Han, Jiaqiang [1 ,2 ]
Wang, Zihao [3 ]
Geng, Pengqiang [1 ]
Wang, Fei [1 ]
Wen, Jennifer [2 ]
Liu, Fang [1 ,4 ,5 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Univ Warwick, Sch Engn, Warwick Fire, Coventry CV4 7AL, W Midlands, England
[3] Chongqing Univ, Coll Environm & Ecol, Chongqing 400045, Peoples R China
[4] Chongqing Univ, Minist Educ, Key Lab New Technol Construct Cities Mt Area, Chongqing 400045, Peoples R China
[5] Joint Int Res Lab Green Bldg & Built Environm, Chongqing 400045, Peoples R China
关键词
Ceiling temperature; Blockage effect; Tunnel slope; Closed portal; Metro fire; LONGITUDINAL VENTILATION; GAS TEMPERATURE; FLOW; FIRES; VELOCITY; BENEATH; TESTS;
D O I
10.1016/j.enbuild.2021.111540
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The current research investigated the coupling effect of blockage and tunnel slope on spreading characteristics of the fire smoke and ceiling temperature distribution in a metro depot with one closed end. A series of 1/15 reduced scale experiments and full-scale numerical simulations were conducted to capture the global fire characteristics. The investigation addressed and compared the effect of tunnel slope on the fire plume behavior and ceiling temperature distribution in both uphill and downhill situations. The presence of the blockage upstream of the fire was further investigated to highlight the heat accumulation between the closed end and fire, and the associated effect on the pool fire mass burning rate. Comparison has been made between the ceiling temperature distribution of when the tunnel slope increases in both uphill and downhill tunnels. The coupling effect of blockage and tunnel slope was analyzed in relation to the maximum and extent of high temperature area at tunnel ceiling. Two empirical correlations have also been proposed to predict the maximum temperature and upstream temperature attenuation in a metro depot, accounting for the influence of blockage and tunnel slope. Comparison among the measurements, predicted values, literature models and data exhibit relatively good agreement. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Effect of the blockage ratio on the smoke extraction efficiency in tunnel fires with natural ventilation
    Wang, Jie
    Fan, Yongjie
    Wei, Yinqiu
    Jiang, Xuepeng
    Lu, Kaihua
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 117
  • [22] Experimental and theoretical studies on the smoke temperature distribution along the tunnel ceiling with natural ventilation by the board-coupled shafts
    Cong, Haiyong
    Bi, Mingshu
    Bi, Yubo
    Jiang, Haipeng
    Li, Yanchao
    Gao, Wei
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 159
  • [23] An experimental investigation on blockage effect of metro train on the smoke back-layering in subway tunnel fires
    Zhang, Shaogang
    Cheng, Xudong
    Yao, Yongzheng
    Zhu, Kai
    Li, Kaiyuan
    Lu, Song
    Zhang, Ruifang
    Zhang, Heping
    APPLIED THERMAL ENGINEERING, 2016, 99 : 214 - 223
  • [24] Water spray flow rate effect on smoke temperature distribution under the ceiling in tunnel fires with longitudinal ventilation
    Wang, Jie
    Xie, Zhicheng
    Lu, Kaihua
    Jiang, Xuepeng
    Zhang, Hongjie
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 79 : 190 - 196
  • [25] Effect of slope on smoke movement and temperature profile in underground utility tunnel
    Wang, Ke
    Lu, Ziping
    Wang, Dong
    Zhou, Xiaodong
    Ju, Xiaoyu
    Yang, Lizhong
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (19) : 10285 - 10300
  • [26] Effect of slope on smoke movement and temperature profile in underground utility tunnel
    Ke Wang
    Ziping Lu
    Dong Wang
    Xiaodong Zhou
    Xiaoyu Ju
    Lizhong Yang
    Journal of Thermal Analysis and Calorimetry, 2023, 148 : 10285 - 10300
  • [27] Experimental studies on fire-induced buoyant smoke temperature distribution along tunnel ceiling
    Hu, L. H.
    Huo, R.
    Wang, H. B.
    Li, Y. Z.
    Yang, R. X.
    BUILDING AND ENVIRONMENT, 2007, 42 (11) : 3905 - 3915
  • [28] Characterization of ceiling smoke temperature profile and maximum temperature rise induced by double fires in a natural ventilation tunnel
    Wang, Qiang
    Wang, Shaoming
    Liu, Huan
    Shen, Jiaying
    Shang, Fengju
    Shi, Congling
    Tang, Fei
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 96
  • [29] Numerical investigation on the effect of tunnel width and slope on ceiling gas temperature in inclined tunnels
    Wang, Zhiyong
    Ding, Long
    Wan, Huaxian
    Ji, Jie
    Gao, Zihe
    Yu, Longxing
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 152 (152)
  • [30] Effect of train fire location on maximum smoke temperature beneath the subway tunnel ceiling
    Cong, Wei
    Shi, Long
    Shi, Zhicheng
    Peng, Min
    Yang, Hui
    Zhang, Shaogang
    Cheng, Xudong
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 97 (97)