Effect of the blockage ratio on the smoke extraction efficiency in tunnel fires with natural ventilation

被引:13
|
作者
Wang, Jie [1 ,3 ,4 ,5 ]
Fan, Yongjie [1 ,3 ,4 ,5 ]
Wei, Yinqiu [1 ,3 ,4 ,5 ]
Jiang, Xuepeng [1 ,3 ,4 ,5 ]
Lu, Kaihua [2 ]
机构
[1] Wuhan Univ Sci & Technol, Sch Resource & Environm Engn, Wuhan 430081, Hubei, Peoples R China
[2] China Univ Geosci Wuhan, Fac Engn, Lumo Rd 388, Wuhan 430074, Hubei, Peoples R China
[3] Hubei Res Ctr Ind Safety Engn Technol, Wuhan 430081, Hubei, Peoples R China
[4] Hubei Key Lab Efficient Utilizat & Agglomerat Met, Wuhan 430081, Hubei, Peoples R China
[5] Wuhan Univ Sci & Technol, Fire Safety Technol Inst, Wuhan 430081, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Blockage ratio; Smoke extraction efficiency; Stack effect; Shaft; Tunnel fire; BOARD-COUPLED SHAFT; TEMPERATURE DISTRIBUTION; ROAD TUNNEL; VELOCITY; FLOW; LENGTH; TRAIN; JET;
D O I
10.1016/j.tust.2021.104165
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation by shafts is widely applied in urban shallow tunnels due to its simple structure, steady smoke extraction efficiency and environment-friendly means. In order to investigate the influence of vehicle blockage on the smoke extraction efficiency of the shaft in tunnel fires, a series of n-heptane fire experiments were conducted in a 1:15 small-scale tunnel model with seven blockage ratios (0, 0.16, 0.24, 0.32, 0.40, 0.48, 0.56). The smoke extraction efficiency is calculated by the measured smoke temperature and CO volume fraction in the shaft and in the tunnel near the exhaust vent. Results show that the smoke extraction efficiency of the tunnel with shafts decreases firstly, then increases and drops lastly with the increasing blockage ratio. The smoke temperature in the shaft and at the downstream tunnel change similarly, which indicates that the vehicle blockage can affect the thermal energy discharged by a shaft. The main influence factors are the blocking effect, the necking effect caused by the blockage and the stack effect of the shaft, resulting in the variability of the smoke extraction efficiency. The smoke extraction efficiency reaches the maximum around the blockage 0.48 in the present tunnel, which can be referred to design the tunnel cross section in engineering applications.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The Effect of Fire Location on Smoke Temperature in Tunnel Fires with Natural Ventilation
    Yuan, Zhongyuan
    Lei, Bo
    Bi, Haiquan
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 2119 - 2124
  • [2] Improvement in smoke extraction efficiency by natural ventilation through a board-coupled shaft during tunnel fires
    Cong, H. Y.
    Wang, X. S.
    Zhu, P.
    Jiang, T. H.
    Shi, X. J.
    APPLIED THERMAL ENGINEERING, 2017, 118 : 127 - 137
  • [3] Effect of blockage ratio on critical velocity in tunnel fires
    Li, Liming
    Cheng, Xudong
    Cui, Yu
    Li, Sen
    Zhang, Heping
    JOURNAL OF FIRE SCIENCES, 2012, 30 (05) : 413 - 427
  • [4] Smoke Diffusion Characteristics in Tunnel Fires using Natural Ventilation
    Yuan, Zhongyuan
    Lei, Bo
    Chen, Pengyun
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1265 - 1271
  • [5] Effect of blockage on critical ventilation velocity in longitudinally ventilated tunnel fires
    Meng, Na
    Hu, Xiangming
    Tian, Mengya
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 106
  • [6] Ceiling temperature distribution and smoke diffusion in tunnel fires with natural ventilation
    Kashef, Ahmed
    Yuan, Zhongyuan
    Lei, Bo
    FIRE SAFETY JOURNAL, 2013, 62 : 249 - 255
  • [7] Effects of fire source position on smoke extraction efficiency by natural ventilation through a board-coupled shaft during tunnel fires
    Cong, Haiyong
    Wang, Xishi
    Kong, Xiangxiao
    Xu, Hongli
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2019, 37 (03) : 3975 - 3984
  • [8] Numerical investigation on the effect of ambient pressure on mechanical smoke extraction efficiency in tunnel fires
    Tan, Tiantian
    Yu, Longxing
    Ding, Long
    Gao, Zihe
    Ji, Jie
    FIRE SAFETY JOURNAL, 2021, 120
  • [9] Influence of upstream blockage on smoke control in tunnel fires
    Li, Ying Zhen
    Ingason, Haukur
    FIRE SAFETY JOURNAL, 2024, 147
  • [10] Effect of blockage ratio on the maximum temperature under the ceiling in tunnel fires
    Li, Liming
    Cheng, Xudong
    Cui, Yu
    Dong, Wenhui
    Mei, Zhibin
    JOURNAL OF FIRE SCIENCES, 2013, 31 (03) : 245 - 257