Parameter optimization and experiment of chirp excitation ultrasound imaging

被引:0
|
作者
Gu Jinhong [1 ]
Wang Supin [1 ]
机构
[1] Xian Jiaotong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Xian 710049, Shaanxi, Peoples R China
关键词
chip transmitting; ultrasound imaging; Signal-to-noise Ratio;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective Parameters that affect image quality in Frequency-Modulated (FM) signal (viz. chirp) transmitting ultrasound imaging are investigated to increase Signal-to-Noise Ratio (SNR) of the present ultrasound image. Method The simulation and acoustical experiment are completed to investigate the image quality with various parameters of FM ultrasound signal transmitting. The energy of the transmitting. ultrasound is increased, and the SNR is increased too. In order to ensure that the axial resolution of the image is not decreased, the convolution method is used to decode the received ultrasound signal. Result The transmitting parameters of FM signal transmitting ultrasound imaging were optimized. The phantom B-mode ultrasound image was gained using the method The quality of the image is better than that of the traditional B-mode image. Conclusion The SNR of ultrasound image could be increased by FM signal transmitting method. The SNR of the image of deeper tissue could be increased about 5 similar to 8db, where the ultrasound signal is attenuated severely.
引用
收藏
页码:1286 / 1289
页数:4
相关论文
共 50 条
  • [31] Optimization of frequential parameters of excitation applied to ultrasound contrast imaging of second harmonic extraction
    Menigot, S.
    Girault, J. -M.
    Voicu, I.
    IRBM, 2012, 33 (03) : 211 - 216
  • [32] Excitation enhanced ultrasound contrast imaging
    Forsberg, F.
    Bautista, R.
    Shi, W.T.
    Vecchio, C.
    Bernardi, R.
    2000, Elsevier Science Ltd, Exeter, United Kingdom (26):
  • [33] Harmonic Chirp Imaging with Ultrasound Contrast Agents at High Frequency
    Williams, Ross
    Needles, Andrew
    Cherin, Emmanuel
    Burns, Peter N.
    Foster, F. Stuart
    Leavens, Claudia
    Sherar, Michael D.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 228 - +
  • [34] Chirp excitation technique to enhance microbubble displacement induced by ultrasound radiation force
    Hu, Yi
    Zhang, Dong
    Zheng, Hairong
    Gong, Xiufen
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2009, 125 (03): : 1410 - 1415
  • [35] Mechanism of chirp excitation
    Das, Sreya
    Jacob, Justin
    Khaneja, Navin
    JOURNAL OF MAGNETIC RESONANCE OPEN, 2022, 10-11
  • [36] Tissue Harmonic Compounded Imaging with Dual-Frequency Chirp Excitation
    Lin, Chin-Hsiang
    Shen, Che-Chou
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 370 - 373
  • [37] Superharmonic Imaging With Chirp Coded Excitation: Filtering Spectrally Overlapped Harmonics
    Harput, Sevan
    McLaughlan, James
    Cowell, David M. J.
    Freear, Steven
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (11) : 1802 - 1814
  • [38] RESEARCH ON MAGNETO-ACOUSTIC IMAGING UNDER CHIRP CURRENT EXCITATION
    Zhang, Shunqi
    Mai, Wenshu
    Wang, Yuheng
    Yin, Tao
    Liu, Zhipeng
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (08)
  • [39] Lamb wave based damage imaging under nonlinear chirp excitation
    Xu, Caibin
    Gao, Guangjian
    Deng, Mingxi
    ULTRASONICS, 2023, 135
  • [40] Dual-Frequency Chirp Excitation for Passive Cavitation Imaging in the Brain
    Lin, Hsiang-Ching
    Fan, Ching-Hsiang
    Ho, Yi-Ju
    Yeh, Chih-Kuang
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (06) : 1127 - 1140