Parameter optimization and experiment of chirp excitation ultrasound imaging

被引:0
|
作者
Gu Jinhong [1 ]
Wang Supin [1 ]
机构
[1] Xian Jiaotong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Xian 710049, Shaanxi, Peoples R China
关键词
chip transmitting; ultrasound imaging; Signal-to-noise Ratio;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective Parameters that affect image quality in Frequency-Modulated (FM) signal (viz. chirp) transmitting ultrasound imaging are investigated to increase Signal-to-Noise Ratio (SNR) of the present ultrasound image. Method The simulation and acoustical experiment are completed to investigate the image quality with various parameters of FM ultrasound signal transmitting. The energy of the transmitting. ultrasound is increased, and the SNR is increased too. In order to ensure that the axial resolution of the image is not decreased, the convolution method is used to decode the received ultrasound signal. Result The transmitting parameters of FM signal transmitting ultrasound imaging were optimized. The phantom B-mode ultrasound image was gained using the method The quality of the image is better than that of the traditional B-mode image. Conclusion The SNR of ultrasound image could be increased by FM signal transmitting method. The SNR of the image of deeper tissue could be increased about 5 similar to 8db, where the ultrasound signal is attenuated severely.
引用
收藏
页码:1286 / 1289
页数:4
相关论文
共 50 条
  • [21] The Effect of Amplitude Modulation on Subharmonic Imaging with Chirp Excitation
    Harput, Sevan
    Arif, Muhammad
    McLaughlan, James
    Cowell, David M. J.
    Freear, Steven
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (12) : 2532 - 2544
  • [22] A New Dynamic Complex Baseband Pulse Compression Method for Chirp-Coded Excitation in Medical Ultrasound Imaging
    Kang, Jinbum
    Kim, Yeajin
    Lee, Wooyoul
    Yoo, Yangmo
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (11) : 1698 - 1710
  • [23] Chirp excitation
    Khaneja, Navin
    JOURNAL OF MAGNETIC RESONANCE, 2017, 282 : 32 - 36
  • [24] Harmonic chirp imaging method for ultrasound contrast agent
    Borsboom, JMG
    Chin, CT
    Bouakaz, A
    Versluis, M
    de Jong, N
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) : 241 - 249
  • [25] Ultrasound second harmonic imaging with a weighted chirp signal
    Kim, DY
    Lee, JC
    Kwon, SJ
    Song, TK
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1477 - 1480
  • [26] Orthogonal Chirp Coded Excitation in a Capacitive Micro-machined Ultrasonic Transducer Array for Ultrasound Imaging: A Feasibility Study
    Kim, Bae-Hyung
    Lee, Seungheun
    Kim, Kang-Sik
    SENSORS, 2019, 19 (04)
  • [27] Parameter Optimization Experiment of Magnetorheological Bearing
    Li, Rui
    Du, PengFei
    Zhou, SiMin
    Zheng, TaiXiong
    FRONTIERS OF MECHANICAL ENGINEERING AND MATERIALS ENGINEERING II, PTS 1 AND 2, 2014, 457-458 : 597 - 601
  • [28] Parameter Optimization Experiment for Soft Proofing
    Zhou, Hongxia
    Lin, Maohai
    ADVANCED GRAPHIC COMMUNICATIONS, PACKAGING TECHNOLOGY AND MATERIALS, 2016, 369 : 73 - 79
  • [29] Orthogonal sparse dictionary based on Chirp echo for ultrasound imaging
    Wang, Ping
    Kong, Lu
    Du, Tingting
    Wang, Linhong
    APPLIED ACOUSTICS, 2019, 156 : 359 - 366
  • [30] CHIRP CODING FOR ULTRASOUND IMAGING OF POLYMER-SHELLED MICROBUBBLES
    Sciallero, Claudia
    Trucco, Andrea
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 29 - 32