Parameter optimization and experiment of chirp excitation ultrasound imaging

被引:0
|
作者
Gu Jinhong [1 ]
Wang Supin [1 ]
机构
[1] Xian Jiaotong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Xian 710049, Shaanxi, Peoples R China
关键词
chip transmitting; ultrasound imaging; Signal-to-noise Ratio;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective Parameters that affect image quality in Frequency-Modulated (FM) signal (viz. chirp) transmitting ultrasound imaging are investigated to increase Signal-to-Noise Ratio (SNR) of the present ultrasound image. Method The simulation and acoustical experiment are completed to investigate the image quality with various parameters of FM ultrasound signal transmitting. The energy of the transmitting. ultrasound is increased, and the SNR is increased too. In order to ensure that the axial resolution of the image is not decreased, the convolution method is used to decode the received ultrasound signal. Result The transmitting parameters of FM signal transmitting ultrasound imaging were optimized. The phantom B-mode ultrasound image was gained using the method The quality of the image is better than that of the traditional B-mode image. Conclusion The SNR of ultrasound image could be increased by FM signal transmitting method. The SNR of the image of deeper tissue could be increased about 5 similar to 8db, where the ultrasound signal is attenuated severely.
引用
收藏
页码:1286 / 1289
页数:4
相关论文
共 50 条
  • [1] On Chirp Excitation and Compression for Ultrasound Imaging
    Danial, Dorin
    Porat, Moshe
    Friedman, Zvi
    2016 IEEE INTERNATIONAL CONFERENCE ON THE SCIENCE OF ELECTRICAL ENGINEERING (ICSEE), 2016,
  • [2] Parameter optimization of pulse compression in ultrasound imaging systems with coded excitation
    Behar, V
    Adam, D
    ULTRASONICS, 2004, 42 (10) : 1101 - 1109
  • [3] Optimization of chirp reversal for ultrasound contrast imaging
    Novell, A.
    van der Meer, S. M.
    Versluis, M.
    de Jong, N.
    Bouakaz, A.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2199 - +
  • [4] Chirp-Coded Pulse Excitation for Ultrasound Elasticity Imaging
    Peng, Hui
    Liu, Dong C.
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [5] Pseudo Chirp-Barker-Golay Coded Excitation in Ultrasound Imaging
    Wang, Mingquan
    Cong, Shan
    Zhang, Shi
    PROCEEDINGS OF THE 30TH CHINESE CONTROL AND DECISION CONFERENCE (2018 CCDC), 2018, : 4035 - 4039
  • [6] Enhanced ultrasound strain imaging using chirp-coded pulse excitation
    Peng, Hui
    Liu, Dong C.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (02) : 130 - 141
  • [7] Intravascular ultrasound chirp imaging
    Maresca, D.
    Jansen, K.
    Renaud, G.
    van Soest, G.
    Li, X.
    Zhou, Q.
    de Jong, N.
    Shung, K. K.
    van der Steen, A. F. W.
    APPLIED PHYSICS LETTERS, 2012, 100 (04)
  • [8] Intravascular Ultrasound Chirp Imaging
    Maresca, David
    Jansen, Krista
    Renaud, Guillaume
    den Dekker, Wijnand
    van Soest, Gijs
    Li, Xiang
    Zhou, Qifa
    Cannata, Jonathan
    Shung, K. Kirk
    van der Steen, Antonius F. W.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2110 - 2113
  • [9] An Efficient Pulse Compression Method of Chirp-Coded Excitation in Medical Ultrasound Imaging
    Yoon, Changhan
    Lee, Wooyoul
    Chang, Jin Ho
    Song, Tai-Kyong
    Yoo, Yangmo
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (10) : 2225 - 2229
  • [10] Chirp-coded excitation imaging with a high-frequency ultrasound annular array
    Mamou, Jonathan
    Ketterling, Jeffrey A.
    Silverman, Ronald H.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (02) : 508 - 513