Clinical investigation of the Nucleus Slim Modiolar Electrode

被引:82
|
作者
Aschendorff, Antje [1 ]
Briggs, Robert [6 ]
Brademann, Goetz [2 ]
Helbig, Silke [3 ]
Hornung, Joachim [4 ]
Lenarz, Thomas [5 ]
Marx, Mathieu [7 ]
Ramos, Angel [10 ]
Stoever, Timo [3 ]
Escude, Bernard [8 ]
James, Chris J. [7 ,9 ]
机构
[1] Univ Freiburg, Freiburg, Germany
[2] Univ Klinikum Schleswig Holstein, Kiel, Germany
[3] Klinikum JW Goethe Univ, Frankfurt, Germany
[4] Univ Klinikum Erlangen, Erlangen, Germany
[5] Hannover Med Sch, Hannover, Germany
[6] Univ Melbourne, Melbourne, Vic, Australia
[7] CHU Toulouse, Toulouse, France
[8] Clin Pasteur Toulouse, Toulouse, France
[9] Cochlear France SAS, 135 Route St Simon, FR-31100 Toulouse, France
[10] Complejo Hosp Univ Insular Materno Infantil, Las Palmas Gran Canaria, Spain
关键词
Cochlear implant; Electrode array; Computed tomography; BEAM COMPUTED-TOMOGRAPHY; COCHLEAR IMPLANT ELECTRODES; SCALAR LOCALIZATION; TEMPORAL BONES; X-RAY; POSITION; ARRAY; CHILDREN; PERIMODIOLAR; OUTCOMES;
D O I
10.1159/000480345
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Aims: The Nucleus CI532 cochlear implant incorporates a new precurved electrode array, i.e., the Slim Modiolar electrode (SME), which is designed to bring electrode contacts close to the medial wall of the cochlea while avoiding trauma due to scalar dislocation or contact with the lateral wall during insertion. The primary aim of this prospective study was to determine the final position of the electrode array in clinical cases as evaluated using flat-panel volume computed tomography. Methods: Forty-five adult candidates for unilateral cochlear implantation were recruited from 8 centers. Eleven surgeons attended a temporal bone workshop and received further training with a transparent plastic cochlear model just prior to the first surgery. Feedback on the surgical approach and use of the SME was collected via a questionnaire for each case. Computed tomography of the temporal bone was performed postoperatively using flat-panel digital volume tomography or cone beam systems. The primary measure was the final scalar position of the SME (completely in scala tympani or not). Secondly, medial-lateral position and insertion depth were evaluated. Results: Forty-four subjects received a CI532. The SME was located completely in scala tympani for all subjects. Pure round window (44% of the cases), extended round window (22%), and inferior and/or anterior cochleostomy (34%) approaches were successful across surgeons and cases. The SME was generally positioned close to the modiolus. Overinsertion of the array past the first marker tended to push the basal contacts towards the lateral wall and served only to increase the insertion depth of the first electrode contact without increasing the insertion depth of the most apical electrode. Complications were limited to tip fold-overs encountered in 2 subjects; both were attributed to surgical error, with both reimplanted successfully. Conclusions: The new Nucleus CI532 cochlear implant with SME achieved the design goal of producing little or no trauma as indicated by consistent scala tympani placement. Surgeons should be carefully trained to use the new deployment method such that tip fold-overs and over insertion may be avoided. (C) 2017 S. Karger AG, Basel
引用
收藏
页码:169 / 179
页数:11
相关论文
共 50 条
  • [41] Hearing preservation in paediatric cochlear implantation with the Nucleus Slim Straight Electrode - our experience
    Schaefer, Simone
    Sladen, Mark
    Nichani, Jaya
    Millward, Kerri
    Lockley, Morag
    O'Driscoll, Martin
    Kluk, Karolina
    Bruce, Iain A.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2025, 64 (01) : 51 - 58
  • [42] Effects of in vivo repositioning of slim modiolar electrodes on electrical thresholds and speech perception
    Sang-Yeon Lee
    Young Seok Kim
    Hyung Dong Jo
    Yoonjoong Kim
    Marge Carandang
    Gene Huh
    Byung Yoon Choi
    Scientific Reports, 11
  • [43] Cochlear Implantation With the Nucleus Slim Straight Electrode in Subjects With Residual Low-Frequency Hearing
    Skarzynski, Henryk
    Lorens, Artur
    Matusiak, Monika
    Porowski, Marek
    Skarzynski, Piotr H.
    James, Chris J.
    EAR AND HEARING, 2014, 35 (02): : E33 - E43
  • [44] Peri-modiolar electrode arrays: A comparison of electrode position in the human temporal bone
    Shepherd, R
    Treaba, C
    Cohen, L
    Pyman, B
    Huigen, J
    Xu, J
    Clark, G
    COCHLEAR IMPLANTS, 1996, : 205 - 209
  • [45] One-Year Hearing Preservation and Speech Outcomes Comparing Slim Modiolar and Lateral Wall Arrays
    Zhan, Kevin Y.
    Walia, Amit
    Durakovic, Nedim
    Wick, Cameron C.
    Buchman, Craig A.
    Shew, Matthew A.
    Herzog, Jacques A.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2023, 169 (02) : 340 - 347
  • [46] Effect of initial switch-on within 24 hours of cochlear implantation using slim modiolar electrodes
    Sunwoo, Woongsang
    Jeon, Hyoung Won
    Choi, Byung Yoon
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [47] Effect of initial switch-on within 24 hours of cochlear implantation using slim modiolar electrodes
    Woongsang Sunwoo
    Hyoung Won Jeon
    Byung Yoon Choi
    Scientific Reports, 11
  • [48] Potential Implications of Slim Modiolar Electrodes for Severely Malformed Cochleae: A Comparison With the Straight Array With Circumferential Electrodes
    Lee, Sang-Yeon
    Choi, Byung Yoon
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2021, 14 (03) : 287 - 294
  • [49] Preservation of cochlear structures and hearing when using the Nucleus Slim Straight (CI422) electrode in children
    Skarzynski, H.
    Matusiak, M.
    Lorens, A.
    Furmanek, M.
    Pilka, A.
    Skarzynski, P. H.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2016, 130 (04): : 332 - 339
  • [50] Dispersed Hydrogel Actuator for Modiolar Hugging Cochlear Implant Electrode Arrays
    Stieghorst, J.
    Doll, T.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (11) : 2294 - 2300