4Pi confocal optical system with phase conjugation

被引:5
|
作者
Kawata, Y
Fujita, K
Nakamura, O
Kawata, S
机构
[1] Department of Applied Physics, Osaka University, Suita
关键词
D O I
10.1364/OL.21.001415
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a 4Pi confocal system that incorporates a phase-conjugate mirror into the system to solve the alignment problem and automatically correct the spherical aberration associated with the conventional 4Pi confocal system when observing a thick sample. The proposed system is experimentally verified by use of cerium-doped barium titanate crystal as the phase-conjugate mirror. The full width of the central peak is similar to 0.15 mu m. We also theoretically verify the advantage of automatic correction of the spherical aberration by calculating the intensity distribution at the focal spot. (C) 1996 Optical Society of America
引用
收藏
页码:1415 / 1417
页数:3
相关论文
共 50 条
  • [21] 4PI IRRADIATION - CATHETRON
    JOSLIN, CA
    BRITISH JOURNAL OF RADIOLOGY, 1969, 42 (504): : 952 - &
  • [22] 4PI SCINTILLATION COUNTER-OPTICAL SPARK-CHAMBER SYSTEM FOR NEUTRAL PARTICLES
    DEMARZO, C
    DISTANTE, A
    GUERRIERO, L
    NICCOLINI, C
    POSA, F
    WALDNER, F
    CHEN, GTY
    FLETCHER, CR
    LANOU, RE
    THORNTON, RK
    BARTON, DS
    LYONS, T
    MARX, M
    ROSENSON, L
    THERN, R
    NUCLEAR INSTRUMENTS & METHODS, 1976, 131 (01): : 47 - 60
  • [23] 4Pi multiphoton polymerization
    Tickunas, T.
    Paipulas, D.
    Purlys, V.
    APPLIED PHYSICS LETTERS, 2020, 116 (03)
  • [24] Aberrations in 4Pi Microscopy
    Hao, Xiang
    Antonello, Jacopo
    Allgeyer, Edward S.
    Bewersdorf, Joerg
    Booth, Martin J.
    OPTICS EXPRESS, 2017, 25 (13): : 14049 - 14058
  • [25] Axial Resolution Enhancement by 4Pi Confocal Fluorescence Microscopy with Two-Photon Excitation
    Glaschick, Sylvia
    Roecker, Carlheinz
    Deuschle, Karen
    Wiedenmann, Joerg
    Oswald, Franz
    Mailaender, Volker
    Nienhaus, G. Ulrich
    JOURNAL OF BIOLOGICAL PHYSICS, 2007, 33 (5-6) : 433 - 443
  • [26] Axial Resolution Enhancement by 4Pi Confocal Fluorescence Microscopy with Two-Photon Excitation
    Sylvia Glaschick
    Carlheinz Röcker
    Karen Deuschle
    Jörg Wiedenmann
    Franz Oswald
    Volker Mailänder
    G. Ulrich Nienhaus
    Journal of Biological Physics, 2007, 33 : 433 - 443
  • [27] Arrangement of a 4Pi microscope for reducing the confocal detection volume with two-photon excitation
    Sandeau, Nicolas
    Giovannini, Hugues
    OPTICS COMMUNICATIONS, 2006, 264 (01) : 123 - 129
  • [28] The 4PI effective action for φ4 theory
    Carrington, ME
    EUROPEAN PHYSICAL JOURNAL C, 2004, 35 (03): : 383 - 392
  • [29] Effects of polarization and phase modulation on the focal spot in 4Pi microscopy
    Liu, Shaocong
    You, Shangting
    Fang, Yue
    Wang, Yifan
    Kuang, Cuifang
    Liu, Xu
    JOURNAL OF MODERN OPTICS, 2016, 63 (12) : 1145 - 1157
  • [30] 4Pi microscopy with negligible sidelobes
    Lang, M. C.
    Staudt, T.
    Engelhardt, J.
    Hell, S. W.
    NEW JOURNAL OF PHYSICS, 2008, 10