Liquid chromatographic-electrospray mass spectrometric determination of cyclosporin A in human plasma

被引:11
|
作者
Zaater, MF [1 ]
Tahboub, YR
Najib, NM
机构
[1] Jordan Univ Sci & Technol, Dept Appl Chem, Irbid 22110, Jordan
[2] IPRC, Amman, Jordan
关键词
cyclosporin A; cyclosporin B; LC-MS; human plasma;
D O I
10.1007/s00216-005-3196-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive and selective liquid chromatography-mass spectrometry (LC-MS) assay has been developed for determination of cyclosporin A (CyA) in human plasma; cyclosporin B (CyB) was used as internal standard (IS). The method utilized a combination of a column-switching valve and a reversed-phase symmetry column. The mobile phase was a 25: 75 (v/v) mixture of 10% aqueous glacial acetic acid and acetonitrile. Running time per single run was less than 10 min. Sample preparation included C-8 SPE of human plasma spiked with the analyte and internal standard, evaporation of the eluate to dryness at 50 degrees C under N-2 gas, and finally reconstitution in the mobile phase. Detection of cyclosporin A and the IS was performed in selected ion-monitoring mode at m/z 601.3 and 594.4 Da for CyA and IS, respectively. Quantitation was achieved by use of the regression equation of relative peak area of cyclosporin to IS against concentration of cyclosporin. The method was validated according to FDA guideline requirements. The linearity of the assay in the range 5.0-400.0 ng mL(-1) was verified as characterized by the least-squares regression line Y = (0.00268 +/- 1.9 x 10(-4)) X + (0.00078 +/- 1.8 x 10(-3)), correlation coefficient, r = 0.9986 +/- 1.1 x 10(-3) (n = 48). Intra and inter-day quality-control measurements in the range 5.0-350.0 ng mL(-1) revealed almost 100% accuracy and <= 9% CV for precision. The mean absolute recovery of CyA was found to be 84.01 +/- 9.9% and the respective relative recovery was 100.3 +/- 9.19. The limit of quantitation (LOQ) achieved was 5 ng mL(-1). Eventually, stability testing of the analyte and IS in plasma or stock solution revealed that both chemicals were very stable when stored for long or short periods of time at room temperature or -20 degrees C.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [31] A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
    Mousavi, Syed Husain Hashemi
    Kobarfard, Farzad
    Husain, Syed Waqif
    Tehrani, Mohammad Saber
    Azar, Parviz Abroomand
    Ahmadkhaniha, Reza
    Mehdizadeh, Amir
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2012, 11 (01): : 59 - 67
  • [32] Liquid chromatographic-mass spectrometric method for quantitative determination of lisinopril in human plasma
    Tashtoush, BM
    Alali, FQ
    Najib, NM
    PHARMAZIE, 2004, 59 (01): : 21 - 24
  • [33] Liquid chromatographic-electrospray ionization-mass spectrometric analysis of cytochrome P450 metabolites of arachidonic acid
    Nithipatikom, K
    Grall, AJ
    Holmes, BB
    Harder, DR
    Falck, JR
    Campbell, WB
    ANALYTICAL BIOCHEMISTRY, 2001, 298 (02) : 327 - 336
  • [34] Liquid chromatography-electrospray ionization tandem mass spectrometric determination of lornoxicam in human plasma
    Kim, Young Hoon
    Ji, Hye Young
    Park, Eun-Seok
    Chae, Soo-Wan
    Lee, Hye Suk
    ARCHIVES OF PHARMACAL RESEARCH, 2007, 30 (07) : 905 - 910
  • [35] Liquid chromatography-electrospray lonization tandem mass spectrometric determination of lornoxicam in human plasma
    Young Hoon Kim
    Hye Young Ji
    Eun -Seok Park
    Soo -Wan Chae
    Hye Suk Lee
    Archives of Pharmacal Research, 2007, 30 : 905 - 910
  • [36] Liquid chromatography-electrospray ionization mass spectrometric method for determination of gliclazide in human plasma
    Ling, Guixia
    Sun, Jin
    Tang, Jingling
    Xu, Xiaodi
    Sun, Yinghua
    He, Zhonggui
    ANALYTICAL LETTERS, 2006, 39 (07) : 1381 - 1391
  • [37] Simple determination of huperzine A in human plasma by liquid chromatographic-tandem mass spectrometric method
    Li, Yun-Xia
    Jiang, Xue-Hua
    Lan, Ke
    Wang, Ling
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (01) : 15 - 20
  • [38] Validation of a liquid chromatographic-tandem mass spectrometric method for the determination of loperamide in human plasma
    Streel, B
    Ceccato, A
    Klinkenberg, R
    Hubert, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (02): : 263 - 273
  • [39] Rapid and selective liquid chromatographic/tandem mass spectrometric method for the determination of fosfomycin in human plasma
    Li, Li
    Chen, Xiaoyan
    Dai, Xiaojian
    Chen, Hui
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 171 - 177
  • [40] Development and validation of a liquid chromatographic/tandem mass spectrometric method for the determination of sertraline in human plasma
    Chen, Xiaoyan
    Duan, Xiaotao
    Dai, Xiaojian
    Zhong, Dafang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (16) : 2483 - 2489