Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy

被引:41
|
作者
Braun, MU [1 ]
Schnabel, A [1 ]
Rauwolf, T [1 ]
Schulze, M [1 ]
Strasser, RH [1 ]
机构
[1] Tech Univ Dresden, Dept Internal Med & Cardiol, Med Clin 2, D-01307 Dresden, Germany
关键词
impedance cardiography; Doppler flow echocardiography; cardiac resynchronization therapy; AV-interval optimization;
D O I
10.1007/s10840-005-2361-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Impedance cardiography (IC) and Doppler echocardiography (DE) are two noninvasive methods to evaluate hemodynamics in patients with dual-chamber pacemakers. The aim of the present study was to compare both techniques in respect to their ability of AV-interval optimization in cardiac resynchronization therapy (CRT) based on cardiac output (CO) measurements. Methods and Results: Twenty-four patients (64 +/- 8 years) with congestive heart failure (EF < 35%; NYHA III-IV) and LBBB (> 150 ms) were evaluated at baseline and 1 month after implantation of a CRT-D. The optimal AV interval was defined by IC and subsequently by transaortic flow DE as the interval corresponding to the highest CO measured at different AV intervals, varying from 60 to 200 ms (with 20 ms increments). For standardization and comparison of both techniques, a fixed atriobiventricular pacing rate of 90 beats/min was used. Absolute values of COmax were higher by IC (5.8 +/- 0.9 l/min) as compared to DE (4.6 +/- 0.9 l/min, p < 0.01). The optimal AV interval as determined by IC varied interindividually from 80-180 ms (mean: 121 +/- 18 ms). In DE, the range was also 80-180 ms with the mean optimal AV interval of 128 +/- 23 ms. Thus, there was a strong correlation for AV-interval optimization in CRT between both methods (r = 0.74; p < 0.001). Conclusion: In CRT, AV-interval optimization based on CO values determined by IC correlates closely to those measured by transaortic flow DE. Impedance cardiography as an easy and cost-effective technique for AV-interval optimization is a promising alternative for routine management of heart failure patients on a beat-to-beat analysis during CRT follow-up.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 50 条
  • [1] Impedance Cardiography as a Noninvasive Technique for Atrioventricular Interval Optimization in Cardiac Resynchronization Therapy
    Martin U. Braun
    Andreas Schnabel
    Thomas Rauwolf
    Matthias Schulze
    Ruth H. Strasser
    Journal of Interventional Cardiac Electrophysiology, 2005, 13 : 223 - 229
  • [2] The Usefulness and Limitations of Impedance Cardiography for Cardiac Resynchronization Therapy Device Optimization
    Ogawa, Kojiro
    Igarashi, Miyako
    Nogami, Akihiko
    Yamamoto, Masayoshi
    Sugano, Akinori
    Sekiguchi, Yukio
    Aonuma, Kazutaka
    Ieda, Masaki
    INTERNATIONAL HEART JOURNAL, 2020, 61 (05) : 896 - 904
  • [3] Cardiac resynchronization therapy tuning with impedance cardiography and echocardiography
    Quintana, A. Garcia
    Lainez, E. Arbelo
    Medina, A.
    Dorta, E. Caballero
    Trujillo, J. R. Ortega
    Bueno, N. Castro
    De Lezo, J. Suarez
    Escofet, M. Diaz
    EUROPEAN HEART JOURNAL, 2006, 27 : 609 - 610
  • [4] Impedance cardiography: a useful and reliable tool in optimization of cardiac resynchronization devices
    Heinroth, Konstantin M.
    Elster, Marcel
    Nuding, Sebastian
    Schlegel, Frithjof
    Christoph, Arnd
    Carter, Justin
    Buerke, Michael
    Werdan, Karl
    EUROPACE, 2007, 9 (09): : 744 - 750
  • [5] Impedance cardiography for atrioventricular interval optimization during permanent left ventricular pacing
    Tse, HF
    Yu, C
    Park, E
    Lau, CP
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01): : 189 - 191
  • [6] The use of impedance cardiography for optimizing the interventricular stimulation interval in cardiac resynchronization therapy—a comparison with left ventricular contractility
    Elena Sciaraffia
    Helena Malmborg
    Stefan Lönnerholm
    Per Blomström
    Carina Blomström Lundqvist
    Journal of Interventional Cardiac Electrophysiology, 2009, 25 : 223 - 228
  • [7] The use of impedance cardiography for optimizing the interventricular stimulation interval in cardiac resynchronization therapy: a comparison with left ventricular contractility
    Sciaraffia, E.
    Malmborg, H.
    Lonnerholm, S.
    Blomstrom, P.
    Lundqvist, C. Blomstrom
    EUROPEAN HEART JOURNAL, 2009, 30 : 1030 - 1030
  • [8] The Role of Atrioventricular and Interventricular Optimization for Cardiac Resynchronization Therapy
    Cobb, Daniel B.
    Gold, Michael R.
    HEART FAILURE CLINICS, 2017, 13 (01) : 209 - +
  • [9] Role of acoustic cardiography in optimizing atrioventricular delays in patients undergoing cardiac resynchronization therapy
    Jasti, Kishan
    Vengala, Srinivas
    Manyam, Harish
    Bhashyam, Siva
    Vido, Diane
    Judson, Kenneth
    Belden, William
    Bonnet, Christopher
    Chenarides, John
    Murali, Srinivas
    JOURNAL OF CARDIAC FAILURE, 2008, 14 (06) : S65 - S66
  • [10] A prospective comparison of echocardiography and device algorithms for atrioventricular and interventricular interval optimization in cardiac resynchronization therapy
    Kamdar, Ravindu
    Frain, Evelyn
    Warburton, Fiona
    Richmond, Laura
    Mullan, Victoria
    Berriman, Thomas
    Thomas, Glyn
    Tenkorang, Joanna
    Dhinoja, Mehul
    Earley, Mark
    Sporton, Simon
    Schilling, Richard
    EUROPACE, 2010, 12 (01): : 84 - 91