Distal plate placement for distal radius fractures limits wrist motion

被引:1
|
作者
Komura, Shingo [1 ]
Tanahashi, Hiroyuki [1 ]
Yamada, Yoshihisa [1 ]
Yokoi, Tatsuo [1 ]
Nonomura, Hidehiko [1 ]
Suzuki, Yasushi [2 ]
机构
[1] Gifu Prefectural Gen Med Ctr, Dept Orthopaed Surg, Gifu 5008717, Japan
[2] Gifu Prefectural Gero Hot Spring Hosp, Dept Orthopaed Surg, Gifu, Japan
关键词
Distal radius fracture; Volar locking plate; Watershed line; Range of motion; Flexor tendons; Hardware removal; LOCKING-PLATE; FIXATION; COMPLICATIONS;
D O I
10.1007/s00590-011-0809-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To investigate the influence of distal plate placement for distal radius fractures on risk of flexor tendon complications and wrist motion by performing hardware removal. Materials and methods Fourteen patients treated with a Synthes 2.4 mm juxta-articular LCP Distal Radius Plate underwent hardware removal at >= 6 months postoperatively when improvement of range of motion and grip strength were obtained. Location of plate placement, condition of the flexor tendons, range of motion, grip strength, and postoperative complications were evaluated. Results The average minimum distance between the plate and joint line was 2.0 mm (range, 0.4-4.5 mm), and average distance at the base of the styloid process was 7.5 mm (range, 4.2-9.6 mm). All plates were located distal to the watershed line. Pathological conditions of flexor tendons were observed in 3 patients-adhesion of flexor pollicis longus in 1 and flexor tendon synovitis in 2-however, there were no cases of abrasion or rupture. The average active wrist flexion improved from 53.6 degrees to 61.1 degrees, extension from 67.5 degrees to 70.7 degrees, and the flexion-extension arc of motion improved from 121.1 degrees to 131.8 degrees. The flexion and flexion-extension arc were significantly improved (P = 0.0003 and P = 0.007, respectively). The average grip strength increased from 18.5 to 19.4 kg (not significant). Temporary median nerve disturbance was observed in 1 patient as a postoperative complication. Conclusions Removal of juxta-articular LCP Distal Radius Plate improved wrist motion. Plates located distal to the watershed line may increase the risk of flexor tendon complications and limit wrist motion.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 50 条
  • [31] Fractures of the distal radius. Indications for plate osteosynthesis
    Matschke, S.
    Wagner, C.
    Wentzensen, A.
    TRAUMA UND BERUFSKRANKHEIT, 2007, 9 (01) : 24 - 30
  • [32] The volar locking plate for extension fractures of the distal radius
    Pillukat, T.
    Fuhrmann, R.
    Windolf, J.
    van Schoonhoven, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 47 - 63
  • [33] Dorsal Locked Plate Fixation of Distal Radius Fractures
    Lutsky, Kevin
    Boyer, Martin
    Goldfarb, Charles
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (07): : 1414 - 1422
  • [34] External Fixation Versus "π" Plate for Distal Radius Fractures
    Kateros, Konstantinos
    Macheras, George
    Galanakos, Spyros P.
    Sofianos, Ioannis
    Papakostas, Ioannis
    Papadakis, Stamatios A.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (01): : 166 - 172
  • [35] Biornechanics and biology of plate fixation of distal radius fractures
    Freeland, AE
    Luber, KT
    HAND CLINICS, 2005, 21 (03) : 329 - +
  • [36] Minimally invasive plate osteosynthesis for distal radius fractures
    Xu-ming Wei
    Zhen-zhong Sun
    Yong-jun Rui
    Xiao-Jun Song
    Indian Journal of Orthopaedics, 2014, 48 : 20 - 24
  • [37] Plate fixation with locking screw for distal fractures of the radius
    Cognet, J. -M.
    Geanah, A.
    Marsal, C.
    Kadoch, V.
    Gouzou, S.
    Simon, P.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (07): : 663 - 672
  • [38] Minimally invasive plate osteosynthesis for distal radius fractures
    Wei, Xu-ming
    Sun, Zhen-zhong
    Rui, Yong-jun
    Song, Xiao-Jun
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (01) : 20 - 24
  • [39] Dorsal nail plate fixation of distal radius fractures
    Rampoldi, Michele
    Marsico, Aldo
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (04): : 472 - 478
  • [40] OSTEOSYNTHESIS OF DISTAL RADIUS FRACTURES WITH A T-PLATE
    RAHMANZADEH, R
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1990, : 657 - 661