Evaluating fidelity of CT based 3D models for Zebrafish conductive hearing system

被引:3
|
作者
Marce-Nogue, Jordi [1 ,2 ]
Liu, Juan [1 ]
机构
[1] Univ Buffalo State Univ New York, Jacobs Sch Med & Biomed Sci, Dept Pathol & Anat Sci, Buffalo, NY 14214 USA
[2] Univ Autonoma Barcelona, Inst Catala Paleontol Miquel Crusafont, Barcelona, Spain
关键词
Zebrafish; Weberian apparatus; CT imaging; Finite element analysis; DANIO-RERIO OSTARIOPHYSI; FINITE-ELEMENT-ANALYSIS; WEBERIAN OSSICLES; BIOMECHANICS; MORPHOLOGY; DIVERSITY; EVOLUTION; SKELETON;
D O I
10.1016/j.micron.2020.102874
中图分类号
TH742 [显微镜];
学科分类号
摘要
The zebrafish Weberian apparatus is an emerging model for human conductive hearing system. Their Weberian apparatus comprises minute bones and ligamentary links, and conducts sound pressure transmission from the gas bladder to inner ear through four pairs of Weberian ossicles along the vertebral column. We herein present a methodological study using MicroCT to image the Weberian apparatus for biomechanical and morphological analysis. The aim of this work is to evaluate computational models generated from multiple MicroCT scans with different parameters, to identify the most feasible scan combination for practical (minimized scan time) yet accurate (relative to highest resolution) biomechanical simulations. We segmented and created 3D models from CT scan image stacks at 4.64 mu m, 5.05 mu m, 9.30 mu m and 13.08 mu m voxel resolutions, respectively. Then, we used geometric morphometrics analysis to quantify inter-model shape differences, as well as a series of finite element modal and harmonic analyses to simulate auditory signal vibrations. Relative to the highest resolution and most accurate model, the Model 9.30 is closest in overall geometry and biomechanical behavior of all lower resolution models. The differences in resolution and quality of the CT substantially affect the segmentation and reconstruction process of the three-dimensional model of the ossicles, and the subsequent analyses. We conclude that scan voxel resolution is a key factor influencing outcomes of biomechanical simulations of delicate and minute structures, especially when studying the harmonic response of minute ossicles connected by ligaments using finite element modeling. Furthermore, contrast variations in CT images as determined by x-ray power and scan speed, also affect fidelity in 3D models and simulation outcomes.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] A web-based collaborative assembly system heterogeneous 3D models
    Wang, QY
    Tian, L
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1 AND 2: INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT IN THE GLOBAL ECONOMY, 2005, : 1039 - 1044
  • [42] 3D Conductive Textile Shields
    Donciu, Codrin
    MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING, 2014, 837 : 340 - 345
  • [43] Study on 4D Information System for NPP Overhaul Based on 3D Models
    Chen G.
    Jiang S.
    Hu S.
    1600, Atomic Energy Press (38): : 180 - 184
  • [44] On the Efficiency of Image Metrics for Evaluating the Visual Quality of 3D Models
    Lavoue, Guillaume
    Larabi, Mohamed Chaker
    Vasa, Libor
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2016, 22 (08) : 1987 - 1999
  • [45] Changes of intrathoracic trachea with respiration in children: A metrical assessment based on 3D CT models
    Cellina, Michaela
    Gibelli, Daniele
    Floridi, Chiara
    Cappella, Annalisa
    Oliva, Giancarlo
    Dolci, Claudia
    Giulia, Signorelli
    Sforza, Chiarella
    CLINICAL IMAGING, 2021, 74 : 10 - 14
  • [46] Reconstructing Recognizable 3D Face Shapes based on 3D Morphable Models
    Jiang, Diqiong
    Jin, Yiwei
    Zhang, Fang-Lue
    Lai, Yu-Kun
    Deng, Risheng
    Tong, Ruofeng
    Tang, Min
    COMPUTER GRAPHICS FORUM, 2022, 41 (06) : 348 - 364
  • [47] Evaluation of a Micro-CT Based 3D Conformal Animal Radiotherapy System
    Zhou, H.
    Xu, J.
    Rodriguez, M.
    van den Haak, F.
    Zhu, X.
    Xian, Y.
    Nelson, G.
    Jogani, R.
    Keall, P.
    Graves, E.
    MEDICAL PHYSICS, 2009, 36 (06) : 2800 - +
  • [48] Mathematical Models of 3D Magnetic Field and 3D Positioning System by Magnetic Field
    Lin, Dong
    Chen, Xin
    APPLIED MATHEMATICS & INFORMATION SCIENCES, 2014, 8 (04): : 1647 - 1654
  • [49] CT-based 3D reconstruction and basic anatomical analysis of the 3D anatomy of the air sac system in domestic birds
    Petnehazy, O.
    Csoka, A.
    Fajtai, D.
    Echols, S.
    Donko, T.
    ANATOMIA HISTOLOGIA EMBRYOLOGIA, 2024, 53 (02)
  • [50] Highly Conductive 3D Printable Materials for 3D Structural Electronics
    Baker, Daina, V
    Bao, Chao
    Kim, Woo Soo
    ACS APPLIED ELECTRONIC MATERIALS, 2021, 3 (06) : 2423 - 2433