Agreement between radial and femoral arterial blood pressure measurements during orthotopic liver. transplantation

被引:0
|
作者
Lee, Matthew [1 ]
Weinberg, Laurence [1 ]
Pearce, Brett [1 ]
Scurrah, Nicholas [1 ]
Story, David A. [1 ,4 ]
Pillai, Param [1 ]
McCall, Peter R. [1 ]
McNicol, Larry P. [2 ]
Peyton, Philip J. [1 ,3 ]
机构
[1] Austin Hosp, Dept Anaesthesia, Melbourne, Vic 3084, Australia
[2] Austin Hosp, Anaesthesia, Melbourne, Vic 3084, Australia
[3] Austin Hosp, Res, Melbourne, Vic 3084, Australia
[4] Univ Melbourne, Fac Med Dent & Hlth Sci, Anaesthesia, Melbourne, Vic, Australia
关键词
CARDIOPULMONARY BYPASS; REPERFUSION; GRADIENT; THERAPY;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To study agreement between radial and femoral arterial pressure measurements in orthotopic liver transplantation (OLTx) surgery to determine whether arterial cannulation sites are interchangeable. Design, setting and participants: Prospective observational study of 25 patients undergoing OLTx surgery. Methods: Radial and femoral arteries were cannulated with standardised arterial line kits. Radial and femoral mean arterial pressure (MAP), systolic arterial pressure (SAP), diastolic arterial pressure (DAP) and pulse pressure (PP) were measured at four time points (30 minutes after induction of anaesthesia, 30 minutes after the start of the anhepatic phase, 30 minutes after liver graft reperfusion and 30 minutes after the start of bile duct anastomosis). Main outcome measures: The bias, precision and limits of agreement between. radial and femoral arterial pressures were calculated in accordance with Bland Altman statistics. Results: Radial femoral differences in MAP (mean difference, 4.8 mmHg [SD, 4.5 mmHg]), limits of agreement (-13.6 and 8.8, P < 0.001) and DAP showed clinically acceptable agreement between measurement sites across all time points. However, clinically significant differences between radial and femoral SAPs (mean differerice, -14.9 mmHg [SD, 24.8 mmHg]) and limits of agreement (-63.5 and 33.7, P < 0.001) occurred overall. This difference started after portal vein clamping and remained significant throughout the remainder of the operation. Conclusion: Radial artery SAP underestimates femoral artery measurements significantly but unpredictably. As femoral measurement is more likely to reflect central arterial pressure, radial SAP measurement is not reliable in adults undergoing OLTx.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [31] Peripheral venous pressure as a predictor of central venous pressure during orthotopic liver transplantation
    Hoftman, Nir
    Braunfeld, Michelle
    Hoftman, Gil
    Mahajan, Aman
    JOURNAL OF CLINICAL ANESTHESIA, 2006, 18 (04) : 251 - 255
  • [32] Radial artery diameter decreases with increased femoral to radial arterial pressure gradient during cardiopulmonary bypass
    Baba, T
    Goto, T
    Yoshitake, A
    Shibata, Y
    ANESTHESIA AND ANALGESIA, 1997, 85 (02): : 252 - 258
  • [33] Mean arterial pressure as the harmonic mean of systolic and diastolic blood pressure in radial and femoral arteries during early septic shock resuscitation
    Chemla, Denis
    Jozwiak, Mathieu
    Hamzaoui, Olfa
    Kattan, Eduardo
    Hernandez, Glenn
    Teboul, Jean-Louis
    BRITISH JOURNAL OF ANAESTHESIA, 2025, 134 (04) : 1190 - 1192
  • [34] Arterial pressure: agreement between a brachial cuff-based device and radial tonometry
    Park, Chloe M.
    Korolkova, Olga
    Davies, Justin E.
    Parker, Kim H.
    Siggers, Jennifer H.
    March, Katherine
    Tillin, Therese
    Chaturvedi, Nish
    Hughes, Alun D.
    JOURNAL OF HYPERTENSION, 2014, 32 (04) : 865 - 872
  • [35] Level of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children
    Garnier, R. P.
    van der Spoel, A. G. E.
    Sibarani-Ponsen, R.
    Markhorst, D. G.
    Boer, C.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) : 609 - 615
  • [36] Upper extremity veno-arterial shunting during pediatric orthotopic liver transplantation
    Henderson, KH
    Everts, EA
    Upton, J
    ANESTHESIOLOGY, 1998, 89 (05) : 1247 - 1249
  • [37] AGREEMENT BETWEEN EMERGENCY MEDICAL SERVICES AND EXPERT BLOOD PRESSURE MEASUREMENTS
    Cienki, John J.
    DeLuca, Lawrence A.
    JOURNAL OF EMERGENCY MEDICINE, 2012, 43 (01): : 64 - 68
  • [38] DIRECT MEASUREMENT OF BLOOD PRESSURE IN THE RADIAL AND FEMORAL ARTERIES DURING AND AFTER TILTING
    GREEN, RS
    IGLAUER, A
    MCGUIRE, J
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1947, 32 (12): : 1511 - 1511
  • [39] THE EFFECT OF APROTININ ON BLOOD PRODUCT REQUIREMENTS DURING ORTHOTOPIC LIVER-TRANSPLANTATION
    BECHSTEIN, WO
    RIESS, H
    NEUHAUS, P
    HIMMELREICH, G
    STEFFEN, R
    SLAMA, KJ
    ROSSAINT, R
    BLUMHARDT, G
    CLINICAL TRANSPLANTATION, 1991, 5 (06) : 422 - 426
  • [40] Balanced Blood Product Transfusion During Orthotopic Liver Transplantation Improves Mortality
    Hogen, Rachel
    Dhanireddy, Kiran
    Clark, Damon
    Biswas, Subarna
    Dinorcia, Joseph
    Yee, Jonson
    Cobb, J. P.
    Strumwasser, Aaron
    AMERICAN JOURNAL OF TRANSPLANTATION, 2017, 17 : 66 - 67