Differentiating the acute phase of gout from the intercritical phase with ultrasound and quantitative shear wave elastography

被引:15
|
作者
Wang, Qiao [1 ]
Guo, Le-Hang [1 ]
Li, Xiao-Long [1 ]
Zhao, Chong-Ke [1 ]
Li, Ming-Xu [1 ]
Wang, Ling [2 ]
Liu, Xin-Ying [2 ]
Xu, Hui-Xiong [1 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Ultrasound Res & Educ Inst,Dept Med Ultrasound, 301 Yanchangzhong Rd, Shanghai 200072, Peoples R China
[2] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Nephrol & Rheumatol, 301 Yanchangzhong Rd, Shanghai 200072, Peoples R China
关键词
Musculoskeletal system; Gout; Ultrasonography; Elastic modulus; Elastography; AMERICAN-COLLEGE; DIAGNOSIS; ARTHRITIS; LESIONS; ULTRASONOGRAPHY; CLASSIFICATION; HYPERURICEMIA; RELIABILITY; CRITERIA; TISSUE;
D O I
10.1007/s00330-018-5529-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo evaluate the value of ultrasound (US) in differentiating the acute phase of gout from the intercritical phase, particularly using shear wave elastography (SWE).Methods57 gout patients were prospectively enrolled and divided into acute phase and intercritical phase groups. The patients underwent US and SWE examinations for the first metatarsophalangeal joints with the same protocol. Maximum synovial thickness was measured. US features were reviewed by two radiologists independently. The maximum (E-max) and mean (E-mean) elastic moduli of synovium were calculated. Diagnostic performances of US, SWE and combined US and SWE were evaluated.ResultsUS findings demonstrated that the colour Doppler flow signal grade in the acute phase was higher than that in the intercritical phase (p = 0.001), whereas no differences were found for B-mode US features between the two groups (all p > 0.05). For SWE, E-max and E-mean were significantly higher in the intercritical phase than in the acute phase (both p < 0.001). The areas under the receiver operating characteristic curve (AUROCs) were 0.494-0.553 for B-mode US, 0.735 for colour Doppler US (CDUS), 0.887 for E-max and 0.882 for E-mean. The combination of CDUS and SWE increased the AUROC, sensitivity and accuracy significantly in comparison with CDUS alone (all p < 0.001). However, the combined set did not show stronger diagnostic performance in comparison with SWE alone.ConclusionSWE increases the diagnostic performance in differentiating the acute phase of gout from the intercritical phase in comparison with conventional US.Key Points center dot Colour Doppler flow signal grade is higher in acute phase of gout than in intercritical phase.center dot SWE demonstrates that synovium stiffness is higher in intercritical phase of gout than in acute phase.center dot SWE increases diagnostic performance in differentiating acute phase of gout from intercritical phase in comparison with conventional US.
引用
收藏
页码:5316 / 5327
页数:12
相关论文
共 50 条
  • [1] Differentiating the acute phase of gout from the intercritical phase with ultrasound and quantitative shear wave elastography
    Qiao Wang
    Le-Hang Guo
    Xiao-Long Li
    Chong-Ke Zhao
    Ming-Xu Li
    Ling Wang
    Xin-Ying Liu
    Hui-Xiong Xu
    European Radiology, 2018, 28 : 5316 - 5327
  • [2] Phase aberration in ultrasound shear wave elastography - impacts on push and tracking
    Huang, Sheng-Wen
    Xie, Hua
    Robert, Jean-Luc
    Man Nguyen
    Shamdasani, Vijay
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [3] THE VALUE OF SONOGRAPHY IN THE INTERCRITICAL PHASE OF GOUT
    Cipolletta, E.
    Di Matteo, A.
    Brunori, G.
    Moretti, A.
    Grassi, W.
    Filippucci, E.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 437 - 437
  • [4] Reverberant shear wave phase gradients for elastography
    Ormachea, J.
    Parker, K. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (17):
  • [5] QUANTITATIVE ASSESSMENT OF KELOIDS USING ULTRASOUND SHEAR WAVE ELASTOGRAPHY
    Guo, Ruiqian
    Xiang, Xi
    Wang, Liyun
    Zhu, Bihui
    Cheng, Shan
    Qiu, Li
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (05): : 1169 - 1178
  • [6] Real-time ultrasound shear wave elastography using a local phase gradient
    González-Mateo, Enrique
    Camarena, Francisco
    Jiménez, Noé
    Computer Methods and Programs in Biomedicine, 2025, 260
  • [7] Local Phase Velocity Based Imaging: A New Technique Used for Ultrasound Shear Wave Elastography
    Kijanka, Piotr
    Urban, Matthew W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (04) : 894 - 908
  • [8] Phantom experiment and clinical utility of quantitative shear wave elastography for differentiating thyroid nodules
    Fukuhara, Takahiro
    Matsuda, Eriko
    Fujiwara, Kazunori
    Tanimura, Chika
    Izawa, Shoichiro
    Kataoka, Hideyuki
    Kitano, Hiroya
    ENDOCRINE JOURNAL, 2014, 61 (06) : 615 - 621
  • [9] Ultrasound Shear Wave Elastography in Cardiology
    Caenen, Annette
    Bezy, Stephanie
    Pernot, Mathieu
    Nightingale, Kathryn R.
    Vos, Hendrik J.
    Voigt, Jens-Uwe
    Segers, Patrick
    D'hooge, Jan
    JACC-CARDIOVASCULAR IMAGING, 2024, 17 (03) : 314 - 329
  • [10] The Predictive Value of Transthoracic Shear-Wave Ultrasound Elastography in Differentiating Benign from Malignant Lung Tumors
    Kuo, Y.
    Chen, Y.
    Shih, J.
    Wang, H.
    Wu, H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199