Differentiating the acute phase of gout from the intercritical phase with ultrasound and quantitative shear wave elastography

被引:15
|
作者
Wang, Qiao [1 ]
Guo, Le-Hang [1 ]
Li, Xiao-Long [1 ]
Zhao, Chong-Ke [1 ]
Li, Ming-Xu [1 ]
Wang, Ling [2 ]
Liu, Xin-Ying [2 ]
Xu, Hui-Xiong [1 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Ultrasound Res & Educ Inst,Dept Med Ultrasound, 301 Yanchangzhong Rd, Shanghai 200072, Peoples R China
[2] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Nephrol & Rheumatol, 301 Yanchangzhong Rd, Shanghai 200072, Peoples R China
关键词
Musculoskeletal system; Gout; Ultrasonography; Elastic modulus; Elastography; AMERICAN-COLLEGE; DIAGNOSIS; ARTHRITIS; LESIONS; ULTRASONOGRAPHY; CLASSIFICATION; HYPERURICEMIA; RELIABILITY; CRITERIA; TISSUE;
D O I
10.1007/s00330-018-5529-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo evaluate the value of ultrasound (US) in differentiating the acute phase of gout from the intercritical phase, particularly using shear wave elastography (SWE).Methods57 gout patients were prospectively enrolled and divided into acute phase and intercritical phase groups. The patients underwent US and SWE examinations for the first metatarsophalangeal joints with the same protocol. Maximum synovial thickness was measured. US features were reviewed by two radiologists independently. The maximum (E-max) and mean (E-mean) elastic moduli of synovium were calculated. Diagnostic performances of US, SWE and combined US and SWE were evaluated.ResultsUS findings demonstrated that the colour Doppler flow signal grade in the acute phase was higher than that in the intercritical phase (p = 0.001), whereas no differences were found for B-mode US features between the two groups (all p > 0.05). For SWE, E-max and E-mean were significantly higher in the intercritical phase than in the acute phase (both p < 0.001). The areas under the receiver operating characteristic curve (AUROCs) were 0.494-0.553 for B-mode US, 0.735 for colour Doppler US (CDUS), 0.887 for E-max and 0.882 for E-mean. The combination of CDUS and SWE increased the AUROC, sensitivity and accuracy significantly in comparison with CDUS alone (all p < 0.001). However, the combined set did not show stronger diagnostic performance in comparison with SWE alone.ConclusionSWE increases the diagnostic performance in differentiating the acute phase of gout from the intercritical phase in comparison with conventional US.Key Points center dot Colour Doppler flow signal grade is higher in acute phase of gout than in intercritical phase.center dot SWE demonstrates that synovium stiffness is higher in intercritical phase of gout than in acute phase.center dot SWE increases diagnostic performance in differentiating acute phase of gout from intercritical phase in comparison with conventional US.
引用
收藏
页码:5316 / 5327
页数:12
相关论文
共 50 条
  • [31] QUANTITATIVE ASSESSMENT OF SKIN STIFFNESS USING ULTRASOUND SHEAR WAVE ELASTOGRAPHY IN SYSTEMIC SCLEROSIS
    Yang, Yujia
    Qiu, Li
    Wang, Liyun
    Xiang, Xi
    Tang, Yuanjiao
    Li, Haocheng
    Yan, Feng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (04): : 902 - 912
  • [32] Quantitative shear-wave optical coherence elastography with a programmable phased array ultrasound as the wave source
    Song, Shaozhen
    Le, Nhan Minh
    Huang, Zhihong
    Shen, Tueng
    Wang, Ruikang K.
    OPTICS LETTERS, 2015, 40 (21) : 5007 - 5010
  • [33] Shear wave elastography using phase sensitive optical coherence tomography
    Song, Shaozhen
    Huang, Zhihong
    Thu-Mai Nguyen
    Wong, Emily Y.
    Arnal, Bastien
    O'Donnell, Matthew
    Wang, Ruikang K.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [34] Phase Aberration in Shear Wave Dispersion Ultrasound Vibrometry
    Shi, Yan
    Xie, Hua
    Shamdasani, Vijay
    Fraser, John
    Robert, Jean-Luc
    Zhou, Shiwei
    Urban, Matthew W.
    Chen, Shigao
    Greenleaf, James F.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2408 - 2411
  • [35] Quantitative Imaging of Nonlinear Shear Modulus by Combining Static Elastography and Shear Wave Elastography
    Latorre-Ossa, Heldmuth
    Gennisson, Jean-Luc
    De Brosses, Emilie
    Tanter, Mickael
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) : 833 - 839
  • [36] Plane wave elastography: a frequency-domain ultrasound shear wave elastography approach
    Khodayi-mehr, Reza
    Urban, Matthew W.
    Zavlanos, Michael M.
    Aquino, Wilkins
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12):
  • [37] The Role of Shear Wave Elastography in Differentiating Idiopathic Granulomatous Mastitis From Breast Cancer
    Makal, Gul Bora
    Guvenc, Inanc
    ACADEMIC RADIOLOGY, 2021, 28 (03) : 339 - 344
  • [38] Utility of Shear Wave Elastography for Differentiating Biliary Atresia From Infantile Hepatitis Syndrome
    Wang, Xiaoman
    Qian, Linxue
    Jia, Liqun
    Bellah, Richard
    Wang, Ning
    Xin, Yue
    Liu, Qinglin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (07) : 1475 - 1479
  • [39] Multisample Ultrasound Point Shear Wave Elastography of the Liver Repeatability and Agreement With Conventional Point Shear Wave Elastography
    Dillman, Jonathan R.
    Trout, Andrew T.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (12) : 2749 - 2756
  • [40] Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury
    Rui Prado-Costa
    João Rebelo
    João Monteiro-Barroso
    Ana Sofia Preto
    Insights into Imaging, 2018, 9 : 791 - 814