Comparing image quality of single- and dual-energy computed tomography of the brain

被引:2
|
作者
Dodig, Doris [1 ]
Kovacic, Slavica [1 ]
Matana Kastelan, Zrinka [1 ]
Zuza, Iva [1 ]
Benic, Filip [1 ]
Slaven, Jurkovic [2 ,3 ]
Miletic, Damir [1 ,4 ]
Rumboldt, Zoran [4 ,5 ]
机构
[1] Clin Hosp Ctr Rijeka, Radiol Dept, Kresimirova 42, Rijeka 51000, Croatia
[2] Clin Hosp Ctr Rijeka, Clin Radiotherapy & Oncol, Rijeka, Croatia
[3] Univ Rijeka, Dept Med Phys & Biophys, Rijeka, Croatia
[4] Univ Rijeka, Dept Radiol, Rijeka, Croatia
[5] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
来源
NEURORADIOLOGY JOURNAL | 2020年 / 33卷 / 03期
关键词
Brain; dual-energy computed tomography; artefacts; image quality; VIRTUAL MONOCHROMATIC RECONSTRUCTION; MONOENERGETIC IMAGES; HEAD CT; FUSION;
D O I
10.1177/1971400920920785
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Purpose Weighted average dual-energy computed tomography (DE-CT) reconstructions are considered a proxy of standard CT images of the brain, recommended for routine clinical use and used as a reference standard in DE-CT research. However, their image quality has not been assessed, which was the aim of our study. Methods Images from 81 consecutive patients who underwent both non-contrast single-energy (SE)-CT and DE-CT of the brain on the same scanner were retrospectively evaluated. Attenuation values (HU) and SD of grey matter/white matter (GM/WM) pairs, along with SD in the posterior fossa and subcalvarial region were measured. Four readers evaluated image noise, GM/WM contrast, posterior fossa and subcalvarial artefacts, as well as overall image quality. Results Weighted average DE-CT GM and WM HU were significantly lower and noise higher compared to SE-CT (GM HU 36.46 v. 41.82; WM HU 28.18 v. 29.94; GM SD 2.93 v. 2.49; and WM SD 3.16 v. 2.44, all p < 0.0001). After correcting the measured SE-CT noise for 37% higher acquisition dose, DE-CT GM noise became significantly lower (2.93 v. 3.11, p = 0.0121). Measured and dose corrected SE-CT GM/WM contrast-to-noise ratio was superior to weighted average DE-CT (3.42 and 2.74 v. 1.95, both p < 0.0001). Weighted average DE-CT had significantly less artifacts on qualitative analysis. Conclusion Weighted average DE-CT images of the brain yield less artefacts at 37% dose reduction and lower noise at SE-CT equivalent dose. Dose-adjusted GM/WM contrast-to-noise ratio of weighted average DE-CT with 0.4 weighting factor remains inferior to SE-CT images.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 50 条
  • [41] Dual-Energy Computed Tomography Applications in Rheumatology
    Park, Eun Hae
    O'Donnell, Thomas
    Fritz, Jan
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2024, 62 (05) : 849 - 863
  • [42] Vascular Applications of Dual-Energy Computed Tomography
    Rajiah, Prabhakar S.
    Kambadakone, Avinash
    Ananthakrishnan, Lakshmi
    Sutphin, Patrick
    Kalva, Sanjeeva P.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 1011 - 1029
  • [43] Dual-Energy Computed Tomography Applications in Neurointervention
    Wolman, Dylan N.
    Patel, Bhavik P.
    Wintermark, Max
    Heit, Jeremy J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 831 - 839
  • [44] Cardiac Applications of Dual-Energy Computed Tomography
    Lempel, Matthew
    Frishman, William H.
    CARDIOLOGY IN REVIEW, 2019, 27 (04) : 208 - 210
  • [45] Dual-energy computed tomography: pediatric considerations
    Gallo-Bernal, Sebastian
    Pena-Trujillo, Valeria
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2024, 54 (13) : 2112 - 2126
  • [46] Single- vs multi-detector row computed tomography of the brain: Blinded assessment of image quality
    Jones, TR
    Kaplan, RT
    Lane, B
    Atlas, SW
    Rubin, GD
    RADIOLOGY, 2000, 217 : 514 - 514
  • [47] Image Enhancement by Spectral-Error Correction for Dual-Energy Computed Tomography
    Park, Kyung-Kook
    Oh, Chang-Hyun
    Akay, Metin
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 8491 - 8494
  • [48] Iodine mapping in brain tumor imaging using dual-energy computed tomography
    Mehndiratta, Amit
    Kapal, Jyoti M.
    Prabu, A.
    MEDICAL HYPOTHESES, 2011, 76 (05) : 764 - 764
  • [49] Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography
    Miura, Hideharu
    Ozawa, Shuichi
    Okazue, Toshiya
    Kawakubo, Atsushi
    Yamada, Kiyoshi
    Nagata, Yasushi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 360 - 366
  • [50] Comparison of Image Quality and Radiation Dose Between Single-Energy and Dual-Energy Images for the Brain With Stereotactic Frames on Dual-Energy Cerebral CT
    Zhao, Xiaojing
    Chao, Wang
    Shan, Yi
    Li, Jingkai
    Zhao, Cheng
    Zhang, Miao
    Lu, Jie
    FRONTIERS IN RADIOLOGY, 2022, 2