Comparing image quality of single- and dual-energy computed tomography of the brain

被引:2
|
作者
Dodig, Doris [1 ]
Kovacic, Slavica [1 ]
Matana Kastelan, Zrinka [1 ]
Zuza, Iva [1 ]
Benic, Filip [1 ]
Slaven, Jurkovic [2 ,3 ]
Miletic, Damir [1 ,4 ]
Rumboldt, Zoran [4 ,5 ]
机构
[1] Clin Hosp Ctr Rijeka, Radiol Dept, Kresimirova 42, Rijeka 51000, Croatia
[2] Clin Hosp Ctr Rijeka, Clin Radiotherapy & Oncol, Rijeka, Croatia
[3] Univ Rijeka, Dept Med Phys & Biophys, Rijeka, Croatia
[4] Univ Rijeka, Dept Radiol, Rijeka, Croatia
[5] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
来源
NEURORADIOLOGY JOURNAL | 2020年 / 33卷 / 03期
关键词
Brain; dual-energy computed tomography; artefacts; image quality; VIRTUAL MONOCHROMATIC RECONSTRUCTION; MONOENERGETIC IMAGES; HEAD CT; FUSION;
D O I
10.1177/1971400920920785
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Purpose Weighted average dual-energy computed tomography (DE-CT) reconstructions are considered a proxy of standard CT images of the brain, recommended for routine clinical use and used as a reference standard in DE-CT research. However, their image quality has not been assessed, which was the aim of our study. Methods Images from 81 consecutive patients who underwent both non-contrast single-energy (SE)-CT and DE-CT of the brain on the same scanner were retrospectively evaluated. Attenuation values (HU) and SD of grey matter/white matter (GM/WM) pairs, along with SD in the posterior fossa and subcalvarial region were measured. Four readers evaluated image noise, GM/WM contrast, posterior fossa and subcalvarial artefacts, as well as overall image quality. Results Weighted average DE-CT GM and WM HU were significantly lower and noise higher compared to SE-CT (GM HU 36.46 v. 41.82; WM HU 28.18 v. 29.94; GM SD 2.93 v. 2.49; and WM SD 3.16 v. 2.44, all p < 0.0001). After correcting the measured SE-CT noise for 37% higher acquisition dose, DE-CT GM noise became significantly lower (2.93 v. 3.11, p = 0.0121). Measured and dose corrected SE-CT GM/WM contrast-to-noise ratio was superior to weighted average DE-CT (3.42 and 2.74 v. 1.95, both p < 0.0001). Weighted average DE-CT had significantly less artifacts on qualitative analysis. Conclusion Weighted average DE-CT images of the brain yield less artefacts at 37% dose reduction and lower noise at SE-CT equivalent dose. Dose-adjusted GM/WM contrast-to-noise ratio of weighted average DE-CT with 0.4 weighting factor remains inferior to SE-CT images.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 50 条
  • [31] Dual-energy computed tomography in pulmonary embolism
    Lu, G-M
    Wu, S-Y
    Yeh, B. M.
    Zhang, L-J
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (992): : 707 - 718
  • [32] Dual-Energy Computed Tomography in Genitourinary Imaging
    Mileto, Achille
    Marin, Daniele
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2017, 55 (02) : 373 - +
  • [33] Dual-Energy Computed Tomography : Technological Considerations
    Chung, Ryan
    Dane, Bari
    Yeh, Benjamin M.
    Morgan, Desiree E.
    Sahani, Dushyant V.
    Kambadakone, Avinash
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 945 - 961
  • [34] Pediatric Applications of Dual-Energy Computed Tomography
    Pena-Trujillo, Valeria
    Gallo-Bernal, Sebastian
    Tung, Erik L.
    Gee, Michael S.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 1069 - 1083
  • [35] Dual-Energy Computed Tomography in Cardiac Imaging
    Boettcher, Benjamin
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Schoepf, Uwe Joseph
    Meinel, Felix G.
    van Assen, Marly
    De Cecco, Carlo N.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 995 - 1009
  • [36] Review of dual-energy computed tomography techniques
    Engler, Philip, 1600, (48):
  • [37] Dual-energy Computed Tomography Applications in Uroradiology
    Jong Park
    Hersh Chandarana
    Michael Macari
    Alec J. Megibow
    Current Urology Reports, 2012, 13 : 55 - 62
  • [38] Dual-energy Computed Tomography Imaging of the Aorta
    Vlahos, Ioannis
    Godoy, Myrna C. B.
    Naidich, David P.
    JOURNAL OF THORACIC IMAGING, 2010, 25 (04) : 289 - 300
  • [39] Dual-Energy Computed Tomography in Body Imaging
    Toia, Giuseppe V.
    Kim, Sooah
    Dighe, Manjiri K.
    Mileto, Achille
    SEMINARS IN ROENTGENOLOGY, 2018, 53 (02) : 132 - 146
  • [40] Dual-Energy Computed Tomography Technology and Challenges
    Krauss, Bernhard
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 497 - +