Comparing image quality of single- and dual-energy computed tomography of the brain

被引:2
|
作者
Dodig, Doris [1 ]
Kovacic, Slavica [1 ]
Matana Kastelan, Zrinka [1 ]
Zuza, Iva [1 ]
Benic, Filip [1 ]
Slaven, Jurkovic [2 ,3 ]
Miletic, Damir [1 ,4 ]
Rumboldt, Zoran [4 ,5 ]
机构
[1] Clin Hosp Ctr Rijeka, Radiol Dept, Kresimirova 42, Rijeka 51000, Croatia
[2] Clin Hosp Ctr Rijeka, Clin Radiotherapy & Oncol, Rijeka, Croatia
[3] Univ Rijeka, Dept Med Phys & Biophys, Rijeka, Croatia
[4] Univ Rijeka, Dept Radiol, Rijeka, Croatia
[5] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
来源
NEURORADIOLOGY JOURNAL | 2020年 / 33卷 / 03期
关键词
Brain; dual-energy computed tomography; artefacts; image quality; VIRTUAL MONOCHROMATIC RECONSTRUCTION; MONOENERGETIC IMAGES; HEAD CT; FUSION;
D O I
10.1177/1971400920920785
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Purpose Weighted average dual-energy computed tomography (DE-CT) reconstructions are considered a proxy of standard CT images of the brain, recommended for routine clinical use and used as a reference standard in DE-CT research. However, their image quality has not been assessed, which was the aim of our study. Methods Images from 81 consecutive patients who underwent both non-contrast single-energy (SE)-CT and DE-CT of the brain on the same scanner were retrospectively evaluated. Attenuation values (HU) and SD of grey matter/white matter (GM/WM) pairs, along with SD in the posterior fossa and subcalvarial region were measured. Four readers evaluated image noise, GM/WM contrast, posterior fossa and subcalvarial artefacts, as well as overall image quality. Results Weighted average DE-CT GM and WM HU were significantly lower and noise higher compared to SE-CT (GM HU 36.46 v. 41.82; WM HU 28.18 v. 29.94; GM SD 2.93 v. 2.49; and WM SD 3.16 v. 2.44, all p < 0.0001). After correcting the measured SE-CT noise for 37% higher acquisition dose, DE-CT GM noise became significantly lower (2.93 v. 3.11, p = 0.0121). Measured and dose corrected SE-CT GM/WM contrast-to-noise ratio was superior to weighted average DE-CT (3.42 and 2.74 v. 1.95, both p < 0.0001). Weighted average DE-CT had significantly less artifacts on qualitative analysis. Conclusion Weighted average DE-CT images of the brain yield less artefacts at 37% dose reduction and lower noise at SE-CT equivalent dose. Dose-adjusted GM/WM contrast-to-noise ratio of weighted average DE-CT with 0.4 weighting factor remains inferior to SE-CT images.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 50 条
  • [1] Dual-Energy Computed Tomography: Is There a Penalty in Image Quality and Radiation Dose Compared With Single-Energy Computed Tomography?
    Thomas, Christoph
    Ketelsen, Dominik
    Tsiflikas, Ilias
    Reimann, Anja
    Brodoefel, Harald
    Claussen, Claus D.
    Heuschmid, Martin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 309 - 315
  • [2] Strategies to Improve Image Quality on Dual-Energy Computed Tomography
    Patel, Bhavik N.
    Marin, Daniele
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 641 - +
  • [3] Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors
    Tanoue, Shota
    Nakaura, Takeshi
    Nagayama, Yasunori
    Uetani, Hiroyuki
    Ikeda, Osamu
    Yamashita, Yasuyuki
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (06) : 951 - 958
  • [4] Comparison of radiation dose and image quality between contrast-enhanced single- and dual-energy abdominopelvic computed tomography in children as a function of patient size
    Siegel, Marilyn J.
    Mhlanga, Joyce C.
    Salter, Amber
    Ramirez-Giraldo, Juan Carlos
    PEDIATRIC RADIOLOGY, 2021, 51 (11) : 2000 - 2008
  • [5] Comparison of radiation dose and image quality between contrast-enhanced single- and dual-energy abdominopelvic computed tomography in children as a function of patient size
    Marilyn J. Siegel
    Joyce C. Mhlanga
    Amber Salter
    Juan Carlos Ramirez-Giraldo
    Pediatric Radiology, 2021, 51 : 2000 - 2008
  • [6] A novel image optimization method for dual-energy computed tomography
    Hao, Jia
    Kang, Kejun
    Zhang, Li
    Chen, Zhiqiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 722 : 34 - 42
  • [7] Usefulness of dual-energy computed tomography for oral cancer image
    Osamu Tanaka
    Makoto Matsubara
    Yuichi Ehara
    Takuya Taniguchi
    Yasunori Muramatsu
    Yasuhisa Hasegawa
    Chiyoko Makita
    Masayuki Matsuo
    Shinichiro Sumitomo
    Oral Radiology, 2021, 37 : 585 - 590
  • [8] Dual-Energy Computed Tomography Image Acquisition, Processing, and Workflow
    Megibow, Alec J.
    Kambadakone, Avinash
    Ananthakrishnan, Lakshmi
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 507 - +
  • [9] A Mathematical Approach to Image Reconstruction on Dual-Energy Computed Tomography
    Kim, Sungwhan
    Ahn, Chi Young
    Kang, Sung-Ho
    Ha, Taeyoung
    Jeon, Kiwan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [10] Usefulness of dual-energy computed tomography for oral cancer image
    Tanaka, Osamu
    Matsubara, Makoto
    Ehara, Yuichi
    Taniguchi, Takuya
    Muramatsu, Yasunori
    Hasegawa, Yasuhisa
    Makita, Chiyoko
    Matsuo, Masayuki
    Sumitomo, Shinichiro
    ORAL RADIOLOGY, 2021, 37 (04) : 585 - 590