Risk Factors for Repeat Infection and Mortality After Extraction of Infected Cardiovascular Implantable Electronic Devices

被引:17
|
作者
Narui, Ryohsuke [1 ]
Nakajima, Ikutaro [1 ]
Norton, Caleb [1 ]
Holmes, Benjamin B. [1 ]
Yoneda, Zachary T. [1 ]
Phillips, Neil [1 ]
Schaffer, Andrew [1 ]
Tinianow, Alex [1 ]
Aboud, Asad A. [1 ]
Stevenson, William G. [1 ]
Richardson, Travis D. [1 ]
Ellis, Christopher R. [1 ]
Crossley, George H. [1 ]
Montgomery, Jay A. [1 ]
机构
[1] Vanderbilt Univ, Dept Med, Cardiovasc Div, Med Ctr, Nashville, TN USA
关键词
CIED extraction; device infection; repeat infection; septic emboli; Staphylococcus aureus; STAPHYLOCOCCUS-AUREUS ENDOCARDITIS; PACEMAKER; PREDICTORS; MANAGEMENT; STATEMENT; OUTCOMES; SURGERY; LEADS;
D O I
10.1016/j.jacep.2021.01.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to investigate the factors associated with repeat infection following lead extraction procedures. BACKGROUND Although lead extraction is an essential therapy for patients with cardiovascular implantable electronic device (CIED) infection, repeat infection still occurs in some patients. METHODS The authors reviewed data for consecutive patients who underwent extraction of infected CIEDs from August 2003 to May 2019. Repeat infection was defined as infective endocarditis, sepsis with no alternative focus, or pocket infection after extraction of infected CIEDs. RESULTS Extraction of infected CIEDs was performed in 496 patients. The most commonly implicated pathogen was Staphylococcus aureus (n = 188). In 449 patients (90.5%), all leads were completely extracted using only transvenous techniques. Thirty-three patients (6.7%) underwent surgical lead extraction, and 14 (2.8%) had retained leads or lead components. After a median follow-up of 352 [40 to 1,255] days after CIED extraction, 144 patients (29.0%) died. Repeat infection occurred in 47 patients (9.5%) with the median time from the extraction to repeat infection of 103 [45 to 214] days. hi muttivariabte analysis, presence of a left ventricular assist device, younger age at extraction, and S. aureus infection were independent predictors of repeat infection. Additionally, chronic kidney disease, congestive heart failure, presence of septic emboli, S. aureus infection, and occurrence of major complications were independent predictors of increased mortality. CONCLUSIONS Patients with S. aureus infection have a high risk of repeat infection and poor prognosis after CIED extraction. Repeat infection is also predicted by younger age and the presence of a left ventricular assist device, whereas mortality was predicted by congestive heart failure, chronic kidney disease, and septic emboli. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:1182 / 1192
页数:11
相关论文
共 50 条
  • [31] Cardiovascular Implantable Electronic Device Infection Procedure Versus Lifetime Risk
    Tarakji, Khaldoun G.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (09) : 1081 - 1083
  • [32] Power supplies for cardiovascular implantable electronic devices
    Deng, Jue
    Sun, Xuemei
    Peng, Huisheng
    ECOMAT, 2023, 5 (06)
  • [33] Radiation Safety and Cardiovascular Implantable Electronic Devices
    Bitterman, Danielle S.
    Zei, Paul C.
    Mak, Raymond H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (02): : 243 - 246
  • [34] Update on Cardiovascular Implantable Electronic Devices for Anesthesiologists
    Cronin, Brett
    Essandoh, Michael K.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (04) : 1871 - 1884
  • [35] Candidemia in patients with cardiovascular implantable electronic devices
    Tomofumi Nakamura
    Ryohsuke Narui
    Benjamin Holmes
    Caleb Norton
    Eun-jeong Kim
    Ikutaro Nakajima
    William G. Stevenson
    Matthew H. Greene
    Roy M. John
    Christopher R. Ellis
    George H. Crossley
    Jay A. Montgomery
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 69 - 75
  • [36] Candidemia in patients with cardiovascular implantable electronic devices
    Nakamura, Tomofumi
    Narui, Ryohsuke
    Holmes, Benjamin
    Norton, Caleb
    Kim, Eun-jeong
    Nakajima, Ikutaro
    Stevenson, William G.
    Greene, Matthew H.
    John, Roy M.
    Ellis, Christopher R.
    Crossley, George H., III
    Montgomery, Jay A.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (01) : 69 - 75
  • [37] Bacterial colonization on the cardiovascular implantable electronic devices
    Okada, M.
    Kashiwase, K.
    Hirata, A.
    Higaki, A.
    Ueda, Y.
    EUROPEAN HEART JOURNAL, 2013, 34 : 1031 - 1031
  • [38] Remote monitoring of cardiovascular implantable electronic devices
    Sticherling, Christian
    Kuehne, Michael
    Schaer, Beat
    Altmann, David
    Osswald, Stefan
    SWISS MEDICAL WEEKLY, 2009, 139 (41-42) : 596 - 601
  • [39] MRI in patients with cardiovascular implantable electronic devices
    Vieira, M. S.
    Lazoura, O.
    Nicol, E.
    Rubens, M.
    Padley, S.
    CLINICAL RADIOLOGY, 2013, 68 (09) : 928 - 934
  • [40] Caring for patients with cardiovascular implantable electronic devices
    Ogg, Mary J.
    AORN JOURNAL, 2013, 98 (02) : 196 - 198