Risk Factors for Repeat Infection and Mortality After Extraction of Infected Cardiovascular Implantable Electronic Devices

被引:17
|
作者
Narui, Ryohsuke [1 ]
Nakajima, Ikutaro [1 ]
Norton, Caleb [1 ]
Holmes, Benjamin B. [1 ]
Yoneda, Zachary T. [1 ]
Phillips, Neil [1 ]
Schaffer, Andrew [1 ]
Tinianow, Alex [1 ]
Aboud, Asad A. [1 ]
Stevenson, William G. [1 ]
Richardson, Travis D. [1 ]
Ellis, Christopher R. [1 ]
Crossley, George H. [1 ]
Montgomery, Jay A. [1 ]
机构
[1] Vanderbilt Univ, Dept Med, Cardiovasc Div, Med Ctr, Nashville, TN USA
关键词
CIED extraction; device infection; repeat infection; septic emboli; Staphylococcus aureus; STAPHYLOCOCCUS-AUREUS ENDOCARDITIS; PACEMAKER; PREDICTORS; MANAGEMENT; STATEMENT; OUTCOMES; SURGERY; LEADS;
D O I
10.1016/j.jacep.2021.01.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to investigate the factors associated with repeat infection following lead extraction procedures. BACKGROUND Although lead extraction is an essential therapy for patients with cardiovascular implantable electronic device (CIED) infection, repeat infection still occurs in some patients. METHODS The authors reviewed data for consecutive patients who underwent extraction of infected CIEDs from August 2003 to May 2019. Repeat infection was defined as infective endocarditis, sepsis with no alternative focus, or pocket infection after extraction of infected CIEDs. RESULTS Extraction of infected CIEDs was performed in 496 patients. The most commonly implicated pathogen was Staphylococcus aureus (n = 188). In 449 patients (90.5%), all leads were completely extracted using only transvenous techniques. Thirty-three patients (6.7%) underwent surgical lead extraction, and 14 (2.8%) had retained leads or lead components. After a median follow-up of 352 [40 to 1,255] days after CIED extraction, 144 patients (29.0%) died. Repeat infection occurred in 47 patients (9.5%) with the median time from the extraction to repeat infection of 103 [45 to 214] days. hi muttivariabte analysis, presence of a left ventricular assist device, younger age at extraction, and S. aureus infection were independent predictors of repeat infection. Additionally, chronic kidney disease, congestive heart failure, presence of septic emboli, S. aureus infection, and occurrence of major complications were independent predictors of increased mortality. CONCLUSIONS Patients with S. aureus infection have a high risk of repeat infection and poor prognosis after CIED extraction. Repeat infection is also predicted by younger age and the presence of a left ventricular assist device, whereas mortality was predicted by congestive heart failure, chronic kidney disease, and septic emboli. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:1182 / 1192
页数:11
相关论文
共 50 条
  • [21] EFFICACY AND FEASIBILITY OF CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICES LEAD EXTRACTION IN ELDERLY PATIENTS
    Nagashima, Michio
    An, Yoshimori
    Ando, Kenji
    Soga, Yoshimitsu
    Nobuyoshi, Masakiyo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E709 - E709
  • [22] Efficacy and feasibility of cardiovascular implantable electronic devices lead extraction in elderly patients
    Nagashima, M.
    An, Y.
    Fukunaga, M.
    Hiroshima, K.
    Yamashita, K.
    Goya, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 375 - 375
  • [23] EFFICACY AND FEASIBILITY OF CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICES LEAD EXTRACTION IN ELDERLY PATIENTS
    Nagashima, M.
    Goya, M.
    Soga, Y.
    Hiroshima, K.
    Hayashi, K.
    Ohe, M.
    Makihara, Y.
    Niu, H.
    Ando, K.
    Iwabuchi, M.
    Nobuyoshi, M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S137 - S138
  • [24] Treatment of Infected Cardiac Implantable Electronic Devices
    Fakhro, Abdulla
    Jalalabadi, Faryan
    Brown, Rodger H.
    Izaddoost, Shayan A.
    SEMINARS IN PLASTIC SURGERY, 2016, 30 (02) : 60 - 65
  • [25] PREVALENCE, MECHANISMS AND RISK FACTORS OF LEAD MACRODISLODGEMENT AFTER IMPLANTATION OF CARDIAC IMPLANTABLE ELECTRONIC DEVICES
    Tseng, Andrew
    Shipman, Justin
    Lee, Justin
    Mi, Lanyu
    Cha, Yong-Mei
    Srivathsan, Komandoor
    Shen, Win-Kuang
    Amin, Mustapha
    Osborn, Michael
    Asirvatham, Samuel
    Friedman, Paul
    Mulpuru, Siva
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 354 - 354
  • [26] Clinical utility of sonication for diagnosing infection and colonization of cardiovascular implantable electronic devices
    Amira H. El-Ashry
    Mohammed Salah A. Hussein
    Khaled Saad
    Amira El Elhoufey
    Medical Microbiology and Immunology, 2021, 210 : 245 - 250
  • [27] Clinical utility of sonication for diagnosing infection and colonization of cardiovascular implantable electronic devices
    El-Ashry, Amira H.
    Hussein, Mohammed Salah A.
    Saad, Khaled
    El Elhoufey, Amira
    MEDICAL MICROBIOLOGY AND IMMUNOLOGY, 2021, 210 (5-6) : 245 - 250
  • [28] Percutaneous Lead Extraction in Infection of Cardiac Implantable Electronic Devices: a Systematic Review
    Menezes Junior, Antonio da Silva
    Magalhaes, Thais Rodrigues
    Alarcao Morais, Alana de Oliveira
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 33 (02) : 194 - 202
  • [29] Extraction of infected cardiac implantable electronic devices and the need for subsequent re-implantation
    Doering, Michael
    Hienzsch, Lisa
    Ebert, Micaela
    Lucas, Johannes
    Dagres, Nikolaos
    Kuehl, Michael
    Hindricks, Gerhard
    Knopp, Helge
    Richter, Sergio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 309 : 84 - 91
  • [30] Cardiac implantable electronic device infection: prevalence and risk factors
    Ghazaryan, N. L.
    Khachatryan, A. H.
    Adamyan, M. Yu
    Hovakimyan, T. B.
    NEW ARMENIAN MEDICAL JOURNAL, 2022, 16 (04): : 96 - 101