Field asymmetric ion mobility spectrometry for pre-symptomatic rot detection in stored Ranger Russet and Russet Burbank potatoes

被引:6
|
作者
Kothawade, Gajanan S. [1 ,2 ]
Chandel, Abhilash K. [1 ,2 ]
Khot, Lav R. [1 ,2 ]
Sankaran, Sindhuja [1 ,2 ]
Bates, Austin A. [3 ]
Schroeder, Brenda K. [3 ]
机构
[1] Washington State Univ, Dept Biol Syst Engn, Pullman, WA 99164 USA
[2] Washington State Univ, Ctr Precis & Automated Agr Syst, Prosser, WA USA
[3] Univ Idaho, Dept Entomol Plant Pathol & Nematol, Moscow, ID USA
基金
美国食品与农业研究所;
关键词
Potato postharvest losses; Soft rot; Pectobacterium carotovorum subsp carotovorum; Volatile organic compounds; FAIMS; SOFT-ROT; ERWINIA-CAROTOVORA; ELECTRONIC NOSE; BROWN-ROT; FULL SEASON; RING ROT; TUBERS; FAIMS; DISCRIMINATION; IDENTIFICATION;
D O I
10.1016/j.postharvbio.2021.111679
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
This study was aimed at early detection and rot progression monitoring in stored potatoes using a portable field asymmetric ion mobility spectrometry (FAIMS) system. Tuber samples of Ranger Russet (RR) and Russet Burbank (RB) cultivars were inoculated with Pectobacterium carotovorumsubsp.carotovorum (causes soft rot) and sterile water (control). The samples were stored in jars either at room temperature (25 degrees C with 30 % relative humidity [RH]) or reduced temperature (4 degrees C with 95 % RH). Volatile headspace from samples was scanned with FAIMS at regular intervals up to 14 days for room temperature and 31 days for reduced temperature storages. Infection symptoms were detected for higher ion current pertinent to headspace of inoculated samples compared to the controls of both the cultivars. Such discrimination was evident at FAIMS compensation voltage (CV)-dispersion field (DF) ranges of -1.70-1.31 V and 38-90 % for room temperature and -1.58-1.31 V and 36-92 % for reduced temperature storages. The rot was detected as early as one day after inoculation (DAI) under room temperature and five DAI under reduced temperature storages. The ion currents were affected by the storage temperature and humidity, and associated interaction with the DAI and cultivar (F-7,F-712 = 21.6-31.4, p < 0.001). The FAIMS responses of control and inoculated tubers were also classified by the Naive Bayes and Random Forest algorithms at accuracies in the ranges of 70-90 % and 75-100 %, respectively. Overall, a portable and tunable FAIMS system was found suitable for high throughput early detection of soft rot in potato tubers. Future studies need to revalidate the FAIMS system in commercial storage facilities for timely rot detection and initiation of potential remedial measures.
引用
收藏
页数:9
相关论文
共 28 条
  • [21] Rapid Detection of Hydrogen Sulfide Gas at Ambient Humidity Based on Nafion-High-Field Asymmetric Waveform Ion Mobility Spectrometry Technology
    Shan, Li
    Zhen, Chen
    Liu, Chang-Jie
    Jiao, Jin
    Han, Wang
    Jun, Hu
    He, Ma
    Shi, Jia-Liang
    Qian, Ren
    Cheng, Yu-Peng
    Liu, You-Jiang
    Chen, Chi-Lai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (06)
  • [22] Detection of Δ9-Tetrahydrocannabinol, Methamphetamine and Amphetamine in air at low ppb level using a Field Asymmetric Ion Mobility Spectrometry microchip sensor
    Mohsen, Yehya
    Gharbi, Nasser
    Lenouvel, Audrey
    Guignard, Cedric
    28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), 2014, 87 : 536 - 539
  • [23] Enhanced Analyte Detection Using In-Source Fragmentation of Field Asymmetric Waveform Ion Mobility Spectrometry-Selected Ions in Combination with Time-of-Flight Mass Spectrometry
    Brown, Lauren J.
    Smith, Robert W.
    Toutoungi, Danielle E.
    Reynolds, James C.
    Bristow, Anthony W. T.
    Ray, Andrew
    Sage, Ashley
    Wilson, Ian D.
    Weston, Daniel J.
    Boyle, Billy
    Creaser, Colin S.
    ANALYTICAL CHEMISTRY, 2012, 84 (09) : 4095 - 4103
  • [24] Simultaneous detection of myostatin-targeting monoclonal antibodies in dried blood spots and plasma using liquid chromatography-tandem mass spectrometry with field asymmetric ion mobility spectrometry
    Lee, Hyeon-Jeong
    Hwang, Jiin
    Seo, Yoondam
    Lee, Gahyeon
    Lee, Hwa Jeong
    Min, Hophil
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 252
  • [25] Detection of volatile organic compounds from wood-based panels by gas chromatography-field asymmetric ion mobility spectrometry (GC-FAIMS)
    Schumann, A.
    Lenth, C.
    Hasener, J.
    Steckel, V.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2012, 15 (03) : 157 - 168
  • [26] Detection, Identification, and Occurrence of Thiotetronic Acids in Drinking Water from Underground Sources by Electrospray Ionization-High Field Asymmetric Waveform Ion Mobility Spectrometry-Quadrupole Time-of-Flight-Mass Spectrometry
    Lyczko, Jadwiga
    Beach, Daniel
    Gabryelski, Wojciech
    ANALYTICAL CHEMISTRY, 2015, 87 (19) : 9884 - 9891
  • [27] Arsenic speciation in marine certified reference materials - Part 1. Identification of water-soluble arsenic species using multidimensional liquid chromatography combined with inductively coupled plasma, electrospray and electrospray high-field asymmetric waveform ion mobility spectrometry with mass spectrometric detection
    McSheehy, S
    Mester, Z
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (03) : 373 - 380