Enhanced Analyte Detection Using In-Source Fragmentation of Field Asymmetric Waveform Ion Mobility Spectrometry-Selected Ions in Combination with Time-of-Flight Mass Spectrometry

被引:32
|
作者
Brown, Lauren J. [1 ]
Smith, Robert W. [1 ]
Toutoungi, Danielle E. [2 ]
Reynolds, James C. [1 ]
Bristow, Anthony W. T. [3 ]
Ray, Andrew [3 ]
Sage, Ashley [4 ]
Wilson, Ian D. [5 ]
Weston, Daniel J. [5 ]
Boyle, Billy [2 ]
Creaser, Colin S. [1 ]
机构
[1] Univ Loughborough, Dept Chem, Ctr Analyt Sci, Loughborough LE11 3TU, Leics, England
[2] Owlstone Ltd, Cambridge CB4 0GD, England
[3] AstraZeneca, Pharmaceut Dev, Macclesfield SK10 2NA, Cheshire, England
[4] Agilent Technol, Stockport SK8 3GR, Lancs, England
[5] AstraZeneca R&D, DMPK Innovat Med, Macclesfield SK10 4TG, Cheshire, England
关键词
ELECTROSPRAY-IONIZATION; TRYPTIC PEPTIDES; SEPARATION; MS;
D O I
10.1021/ac300212r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Miniaturized ultra high field asymmetric waveform ion mobility spectrometry (FAIMS) is used for the selective transmission of differential mobility-selected ions prior to in-source collision-induced dissociation (CID) and time-of-flight mass spectrometry (TOFMS) analysis. The FAIMS-in-source collision induced dissociation-TOFMS (FISCID-MS) method requires only minor modification of the ion source region of the mass spectrometer and is shown to significantly enhance analyte detection in complex mixtures. Improved mass measurement accuracy and simplified product ion mass spectra were observed following FAIMS preselection and subsequent in source CID of ions derived from pharmaceutical excipients, sufficiently close in m/z (17.7 ppm mass difference) that they could not be resolved by TOFMS alone. The FISCID-MS approach is also demonstrated for the qualitative and quantitative analysis of mixtures of peptides with FAIMS used to filter out unrelated precursor ions thereby simplifying the resulting product ion mass spectra. Liquid chromatography combined with FISCID-MS was applied to the analysis of coeluting model peptides and tryptic peptides derived from human plasma proteins, allowing precursor ion selection and CID to yield product ion data suitable for peptide identification via database searching. The potential of FISCID-MS for the quantitative determination of a model peptide spiked into human plasma in the range of 0.45-9.0 mu g/mL is demonstrated, showing good reproducibility (%RSD < 14.6%) and linearity (R-2 > 0.99).
引用
收藏
页码:4095 / 4103
页数:9
相关论文
共 50 条
  • [1] Ion Source with Magnetic Field for Time-of-Flight Mass Spectrometry
    Karataev, V. I.
    Aruev, N. N.
    TECHNICAL PHYSICS LETTERS, 2011, 37 (06) : 575 - 578
  • [2] Ion source with magnetic field for time-of-flight mass spectrometry
    V. I. Karataev
    N. N. Aruev
    Technical Physics Letters, 2011, 37 : 575 - 578
  • [3] Detection of microcystins using electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry/mass spectrometry
    Ells, B
    Froese, K
    Hrudey, SE
    Purves, RW
    Guevremont, R
    Barnett, DA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (16) : 1538 - 1542
  • [4] In-source fragmentation and accurate mass analysis of multiclass flavonoid conjugates by electrospray ionization time-of-flight mass spectrometry
    Abranko, Laszlo
    Garcia-Reyes, Juan F.
    Molina-Diaz, Antonio
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (05): : 478 - 488
  • [5] High-Field Asymmetric Waveform Ion Mobility Spectrometry for Determining the Location of In-Source Collision-induced Dissociation in Electrospray Ionization Mass Spectrometry
    Xia, Yuan-Qing
    Jemal, Mohammed
    ANALYTICAL CHEMISTRY, 2009, 81 (18) : 7839 - 7843
  • [6] Multiplexed ion mobility spectrometry-orthogonal time-of-flight mass spectrometry
    Belov, Mikhail E.
    Buschbach, Michael A.
    Prior, David C.
    Tang, Keqi
    Smith, Richard D.
    ANALYTICAL CHEMISTRY, 2007, 79 (06) : 2451 - 2462
  • [7] Pharmaceutical Metabolite Profiling Using Quadrupole/Ion Mobility Spectrometry/Time-of-Flight Mass Spectrometry
    Chan, Eric Chun Yong
    New, Lee Sun
    Yap, Chun Wei
    Goh, Lin Tang
    DRUG METABOLISM REVIEWS, 2009, 41 : 53 - 53
  • [8] Pharmaceutical metabolite profiling using quadrupole/ion mobility spectrometry/time-of-flight mass spectrometry
    Chan, Eric C. Y.
    New, Lee Sun
    Yap, Chun Wei
    Goh, Lin Tang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (03) : 384 - 394
  • [9] Dynamically multiplexed ion mobility time-of-flight mass spectrometry
    Belov, Mikhail E.
    Clowers, Brian H.
    Prior, David C.
    Danielson, William F., III
    Liyu, Andrei V.
    Petritis, Brianne O.
    Smith, Richard D.
    ANALYTICAL CHEMISTRY, 2008, 80 (15) : 5873 - 5883
  • [10] Identification of N-Nitrosamines in Treated Drinking Water Using Nanoelectrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry with Quadrupole Time-of-Flight Mass Spectrometry
    Zhao, Yuan Yuan
    Liu, Xin
    Boyd, Jessica M.
    Qin, Feng
    Li, Jianjun
    Li, Xing-Fang
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2009, 47 (01) : 92 - 96