Ion source with magnetic field for time-of-flight mass spectrometry

被引:0
|
作者
V. I. Karataev
N. N. Aruev
机构
[1] Russian Academy of Sciences,Ioffe Physical Technical Institute
来源
Technical Physics Letters | 2011年 / 37卷
关键词
Magnetic Field Strength; Technical Physic Letter; Ionization Zone; High Analytical Performance; Electron Impact Ionization Source;
D O I
暂无
中图分类号
学科分类号
摘要
A new ion source for the time-of-flight mass spectrometer (TOFMS) with electron-impact ionization and built-in permanent magnet for electron-beam focusing is described. The focusing of electrons in a homogeneous field leads to an increase in the resolving power and sensitivity of the TOFMS. A spectrometer with the proposed source can operate at electron energies within the 7–100-eV range. The method of suppressing spurious lines in the mass spectrum is described, which is based on a decrease in the energy of ionizing electrons.
引用
收藏
页码:575 / 578
页数:3
相关论文
共 50 条
  • [1] Ion Source with Magnetic Field for Time-of-Flight Mass Spectrometry
    Karataev, V. I.
    Aruev, N. N.
    [J]. TECHNICAL PHYSICS LETTERS, 2011, 37 (06) : 575 - 578
  • [2] Superimposition of a magnetic field around an ion guide for electron ionization time-of-flight mass spectrometry
    Yue, BF
    Lee, ED
    Rockwood, AL
    Lee, ML
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (13) : 4167 - 4175
  • [3] Time-of-flight mass spectrometry studies of an ion beam generated by the titan source
    Bugaev A.S.
    Gushenets V.I.
    Nikolaev A.G.
    Oks E.M.
    Yushkov G.Yu.
    [J]. Russian Physics Journal, 2000, 43 (2) : 96 - 103
  • [4] A segmented ring, cylindrical ion trap source for time-of-flight mass spectrometry
    Ji, QC
    Davenport, MR
    Enke, CG
    Holland, JF
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (10) : 1009 - 1017
  • [5] Study of a pulsed glow discharge ion source for time-of-flight mass spectrometry
    Su, YX
    Zhou, Z
    Yang, PY
    Wang, XR
    Huang, BL
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (05) : 633 - 641
  • [6] Optimization of a quadrupole ion storage trap as a source for time-of-flight mass spectrometry
    Dangi, Beni B.
    Ervin, Kent M.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 41 - 48
  • [7] Time-of-flight secondary ion mass spectrometry of fullerenes
    Saldi, F
    Marie, Y
    Gao, Y
    Simon, C
    Migeon, HN
    Begin, D
    Mareche, JF
    [J]. EUROPEAN MASS SPECTROMETRY, 1995, 1 (05): : 487 - 492
  • [8] ION ASSOCIATION BY TIME-OF-FLIGHT MASS-SPECTROMETRY
    HUANG, LQ
    CONZEMIUS, RJ
    JUNK, GA
    HOUK, RS
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 90 (01): : 85 - 96
  • [9] SECONDARY ION MASS-SPECTROMETRY BY TIME-OF-FLIGHT
    STANDING, KG
    BEAVIS, R
    ENS, W
    SCHUELER, B
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 53 (SEP): : 125 - 134
  • [10] Development of a new electron ionization/field ionization ion source for gas chromatography/time-of-flight mass spectrometry
    Miyamoto, Kenji
    Fujimaki, Susumu
    Ueda, Yoshihisa
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (20) : 3350 - 3354