Benchmarking software for slagging, fouling and other parameters to improve coal-fired power plant load factor, efficiency and emission

被引:0
|
作者
Parker, Ken R.
Allen, Jeff
Sanyal, Anupam
机构
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For a 500 MW unit, a 1% reduction in boiler efficiency equates to a coal cost in the order of $ 1/2 million/annum, while a 5 % unit derate, needed to meet emission compliance, can equate to an annual revenue loss of up to $ 12 million. The implementation of SCES in providing meaningful rankings alerts the plant operators to the performance they can expect and any measures that need to be taken to be able the plant to operate at its highest load factor and efficiency while under emission compliance with minimum impact on O & M cost. Many software products are in use, which based on the present plant performance, identify and optimize the operational parameters for the best plant capacity, utilization and efficiency. While they are effective in tuning up the unit, they are applied to an operating plant firing a given coal for the given performance. But what if there were a means of predicting how a coal will perform with respect to slagging, fouling and every other single parameter involved in the use of that coal for capacity, efficiency maximization and emission control without firing even a lb of coal? This would enable the operator to know in advance what to expect and thereby, adjust the operating variables to get the best out of that coal. Such a software product - SCES (Steam Coal Evaluation & Services) has been developed based on the fundamental principles of combustion, mineral matter transformation and emission of particulates, NOx,SO2 and mercury, based on only the standard ASTM coal and ash analyses. The operational parameters evaluated are: Slagging and fouling as well as Grindability, Abrasion of the grinding elements; Combustibility & Unburnt carbon, Corrosion and Erosion; Emission of particulates, the oxides of sulfiir and nitrogen (both primary and secondary DeNO(x)) as well as mercury when data are available. Its advantage over the existing products is its ability to predict, amongst others parameters, corrosion, erosion of convective tubes and the life of grinding elements none of which are discernible from the existing software products or from a limited test bum. These parameters however play important roles in the bottom line O & M costs. The implementation of SCES in providing meaningful rankings alerts the plant operators to the performance they can expect and any measures that need to be taken to be able the plant to operate at its highest load factor and efficiency while under emission compliance with minimum impact on O & M cost. No separate coal sample or small-scale laboratory evaluation work is required in the derivation of the rankings. Because of its simplicity of use and immediate availability of results, SCES can also be used as a routine analytical tool, accompanying the coal analyses by the plant or supplied with each delivery of coal. It is applicable to all coals irrespective of rank and country of origin, it has been used and validated on coals from the US, UK, Russia, Columbia and India. The paper describes the fundamental properties coal used in the development of the software and cites case histories of its validation on US (Bituminous & Sub-bituminous) coals.
引用
收藏
页码:579 / 583
页数:5
相关论文
共 50 条
  • [41] Comparison of the efficiency of the variants of a primary gas turbine supplementing a coal-fired power plant
    Szargut, J
    Szczygiel, I
    ENERGY, 2005, 30 (07) : 1204 - 1217
  • [42] Study of ash fouling on the blade of induced fan in a 330 MW coal-fired power plant with ultra-low pollutant emission
    Wang, Yibin
    Tan, Houzhang
    Dong, Kun
    Liu, Hexin
    Xiao, Jiafan
    Zhang, Junjie
    APPLIED THERMAL ENGINEERING, 2017, 118 : 283 - 291
  • [43] The influence of membrane CO2 separation on the efficiency of a coal-fired power plant
    Kotowicz, Janusz
    Chmielniak, Tadeusz
    Janusz-Szymanska, Katarzyna
    ENERGY, 2010, 35 (02) : 841 - 850
  • [44] INVESTIGATION ON CLASSIFICATION EFFICIENCY FOR COAL-FIRED POWER PLANT CLASSIFIERS USING A NUMERICAL APPROACH
    Ismail, Firas B.
    Al-Muhsen, Nizar F. O.
    Lingam, Raveen
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2020, 15 (03): : 1542 - 1561
  • [45] Study on Model of Ash Fouling Monitoring in Rotary Air Preheater of Coal-fired Power Plant Boiler
    Wei, Ziyang
    Wang, Jingcheng
    Wang, Hongyuan
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 4447 - 4452
  • [46] The influence of the selected parameters on the economic characteristics of a coal-fired power plant with CCS installation
    Kotowicz, Janusz
    Janusz-Szymanska, Katarzyna
    SCIENTIFIC JOURNALS OF THE MARITIME UNIVERSITY OF SZCZECIN-ZESZYTY NAUKOWE AKADEMII MORSKIEJ W SZCZECINIE, 2010, 23 (95): : 80 - 85
  • [47] Emission Characteristics of Particulate Matter from Coal-Fired Power Units with Different Load Conditions
    Wu, Yujia
    Xu, Zhenyao
    Liu, Siqi
    Tang, Minghui
    Lu, Shengyong
    WATER AIR AND SOIL POLLUTION, 2022, 233 (11):
  • [48] Emission Characteristics of Particulate Matter from Coal-Fired Power Units with Different Load Conditions
    Yujia Wu
    Zhenyao Xu
    Siqi Liu
    Minghui Tang
    Shengyong Lu
    Water, Air, & Soil Pollution, 2022, 233
  • [49] Tradeoff between the efficiency penalty and load depth in a coal-fired power plant with CO2 capture under partial load conditions
    Wang, Chaowei
    He, Song
    Liu, Lianbo
    Li, Xiang
    Gao, Lin
    ENERGY CONVERSION AND MANAGEMENT, 2023, 278
  • [50] MUTAGENIC EFFLUENTS FROM A COAL-FIRED POWER-PLANT - SHORT-TERM VARIATIONS AND RELATION TO POWER LOAD AND OTHER LOAD-DEPENDENT EMISSIONS
    VICTORIN, K
    JANTUNEN, MJ
    ITKONEN, A
    AHLBORG, UG
    STAHLBERG, M
    HONKASALO, S
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (04) : 400 - 404