Benchmarking software for slagging, fouling and other parameters to improve coal-fired power plant load factor, efficiency and emission

被引:0
|
作者
Parker, Ken R.
Allen, Jeff
Sanyal, Anupam
机构
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For a 500 MW unit, a 1% reduction in boiler efficiency equates to a coal cost in the order of $ 1/2 million/annum, while a 5 % unit derate, needed to meet emission compliance, can equate to an annual revenue loss of up to $ 12 million. The implementation of SCES in providing meaningful rankings alerts the plant operators to the performance they can expect and any measures that need to be taken to be able the plant to operate at its highest load factor and efficiency while under emission compliance with minimum impact on O & M cost. Many software products are in use, which based on the present plant performance, identify and optimize the operational parameters for the best plant capacity, utilization and efficiency. While they are effective in tuning up the unit, they are applied to an operating plant firing a given coal for the given performance. But what if there were a means of predicting how a coal will perform with respect to slagging, fouling and every other single parameter involved in the use of that coal for capacity, efficiency maximization and emission control without firing even a lb of coal? This would enable the operator to know in advance what to expect and thereby, adjust the operating variables to get the best out of that coal. Such a software product - SCES (Steam Coal Evaluation & Services) has been developed based on the fundamental principles of combustion, mineral matter transformation and emission of particulates, NOx,SO2 and mercury, based on only the standard ASTM coal and ash analyses. The operational parameters evaluated are: Slagging and fouling as well as Grindability, Abrasion of the grinding elements; Combustibility & Unburnt carbon, Corrosion and Erosion; Emission of particulates, the oxides of sulfiir and nitrogen (both primary and secondary DeNO(x)) as well as mercury when data are available. Its advantage over the existing products is its ability to predict, amongst others parameters, corrosion, erosion of convective tubes and the life of grinding elements none of which are discernible from the existing software products or from a limited test bum. These parameters however play important roles in the bottom line O & M costs. The implementation of SCES in providing meaningful rankings alerts the plant operators to the performance they can expect and any measures that need to be taken to be able the plant to operate at its highest load factor and efficiency while under emission compliance with minimum impact on O & M cost. No separate coal sample or small-scale laboratory evaluation work is required in the derivation of the rankings. Because of its simplicity of use and immediate availability of results, SCES can also be used as a routine analytical tool, accompanying the coal analyses by the plant or supplied with each delivery of coal. It is applicable to all coals irrespective of rank and country of origin, it has been used and validated on coals from the US, UK, Russia, Columbia and India. The paper describes the fundamental properties coal used in the development of the software and cites case histories of its validation on US (Bituminous & Sub-bituminous) coals.
引用
收藏
页码:579 / 583
页数:5
相关论文
共 50 条
  • [21] EMISSIONS OF MERCURY AND OTHER TRACE ELEMENTS FROM A COAL-FIRED POWER PLANT
    Lu, Ping
    Li, Chuantong
    Wu, Jiang
    Pan, Wei-Ping
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 3, 2009, : 195 - 200
  • [22] Research on evaluation method of coal-fired power plant boiler system efficiency
    He, Cheng-Bing
    Liu, Jing
    Gu, Yu-Jiong
    Meitan Xuebao/Journal of the China Coal Society, 2015, 40 (04): : 951 - 958
  • [23] Assessment of carbon capture thermodynamic limitation on coal-fired power plant efficiency
    Le Moullec, Yann
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2012, 7 : 192 - 201
  • [24] Safety and efficiency assessment of a solar-aided coal-fired power plant
    Li, Jianlan
    Wu, Zhiyi
    Zeng, Kuo
    Flamant, Gilles
    Ding, Aosuang
    Wang, Jizhou
    ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 714 - 724
  • [25] Improve technical efficiency of China's coal-fired power enterprises: Taking a coal-fired-withdrawl context
    Li, Gao
    Ruonan, Li
    Yingdan, Mei
    Xiaoli, Zhao
    Energy, 2022, 252
  • [26] Estimating PM Emission Factor from Coal-Fired Power Plants in Korea
    Jang, Kee-Won
    Kim, Hyoung-Chun
    Lee, Yong-Mi
    Song, Deok-Jong
    Jung, Noel
    Kim, Sang-Kyun
    Hong, Ji-Hyung
    Lee, Suk-Jo
    Han, Jong-Su
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2011, 27 (05) : 485 - 493
  • [27] THE OPERATING PARAMETERS SENSITIVE ANALYSIS OF ENERGY CONSUMPTION FOR COAL-FIRED POWER PLANT
    Wang, Hui-Jie
    Zhang, Chun-Fa
    Zhao, Ning
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, VOLS 1 AND 2, 2008, : 862 - 867
  • [28] Greenhouse gas emission factor development for coal-fired power plants in Korea
    Jeon, Eui-Chan
    Myeong, Soojeong
    Sa, Jae-Whan
    Kim, Jinsu
    Jeong, Jae-Hak
    APPLIED ENERGY, 2010, 87 (01) : 205 - 210
  • [29] Improve technical efficiency of China's coal-fired power enterprises: Taking a coal-fired-withdrawl context
    Gao, Li
    Li, Ruonan
    Mei, Yingdan
    Zhao, Xiaoli
    ENERGY, 2022, 252
  • [30] Effects of Ultralow-Emission Retrofitting on Mercury Emission from a Coal-Fired Power Plant
    Liu, Songtao
    Hao, Hongke
    Jia, Wenbo
    Cao, Yue
    Chen, Chuanmin
    ENERGY & FUELS, 2020, 34 (06) : 7502 - 7508