Geometric Reproducibility of Fiducial Markers and Efficacy of a Patient-Specific Margin Design Using Active Breath Hold for Pancreas Stereotactic Body Radiation Therapy

被引:0
|
作者
Han-Oh, S. [1 ]
Nobile, L. [1 ]
Laub, W. [1 ]
Davies, G. [1 ]
Watson, A. [1 ]
Stephens, D. [1 ]
Meyer, J. J. [1 ]
Narang, A. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD USA
关键词
D O I
10.1016/j.ijrobp.2018.07.420
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
SU_18_2175
引用
收藏
页码:E73 / E74
页数:2
相关论文
共 46 条
  • [1] Geometric Reproducibility of Fiducial Markers and Efficacy of a Patient-Specific Margin Design Using Deep Inspiration Breath Hold for Stereotactic Body Radiation Therapy for Pancreatic Cancer
    Han-Oh, Sarah
    Hill, Colin
    Wang, Ken Kang-Hsin
    Ding, Kai
    Wright, Jean L.
    Alcorn, Sara
    Meyer, Jeffrey
    Herman, Joseph
    Narang, Amol
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (02)
  • [2] Online verification of breath-hold reproducibility using kV-triggered imaging for liver stereotactic body radiation therapy
    Guo, Bingqi
    Stephans, Kevin
    Woody, Neil
    Antolak, Alexander
    Moazzezi, Mojtaba
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (09):
  • [3] Geometric and Clinical Factors Affecting Active Fiducial Tracking in Robotic Stereotactic Body Radiation Therapy in the Lung
    Huynh, D.
    Patlolla, A.
    Patel, E.
    Patel, K.
    Sharma, S.
    Bowling, M. R.
    Arastu, H. H.
    Ju, A. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E306 - E307
  • [4] Patient-specific motion and treatment margins in pancreatic stereotactic body radiation therapy
    Miften, M.
    Jones, B. L.
    Fukami, N.
    Schefter, T.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S198 - S199
  • [5] Efficacy and safety of ultrasound-guided implantation of fiducial markers in the liver for stereotactic body radiation therapy
    Park, So Hyun
    Won, Hyung Jin
    Kim, So Yeon
    Shin, Yong Moon
    Kim, Pyo Nyun
    Yoon, Sang Min
    Park, Jin-hong
    Kim, Jong Hoon
    PLOS ONE, 2017, 12 (06):
  • [6] Influence of intra- and interfraction motion on planning target volume margin in liver stereotactic body radiation therapy using breath hold
    Oliver, Patricia A. K.
    Yewondwossen, Mammo
    Summers, Clare
    Shaw, Conor
    Cwajna, Slawa
    Syme, Alasdair
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (01)
  • [7] Motion Management in a Patient With Tracheostomy During Lung Stereotactic Body Radiation Therapy: Breath Hold Is Worth a Try
    Kaestner, Lena
    Abo-Madyan, Yasser
    Huber, Lena
    Spaniol, Manon
    Siebenlist, Kerstin
    Sacks, Marie-Kristin
    Ehmann, Michael
    Stieler, Florian
    Clausen, Sven
    Lohr, Frank
    Fleckenstein, Jens
    Boda-Heggemann, Judit
    ADVANCES IN RADIATION ONCOLOGY, 2022, 7 (03)
  • [8] Patient-specific PTV margins for liver stereotactic body radiation therapy determined using support vector classification with an early warning system for margin adaptation
    Liu, Ming
    Cygler, Joanna E.
    Vandervoort, Eric
    MEDICAL PHYSICS, 2020, 47 (10) : 5172 - 5182
  • [9] Patient-specific quality assurance using machine log files analysis for stereotactic body radiation therapy (SBRT)
    Chow, Vivian U. Y.
    Kan, Monica W. K.
    Chan, Anthony T. C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 179 - 187
  • [10] Prospective validation of treatment accuracy using implanted fiducial markers for spinal stereotactic body radiation therapy
    Weksberg, David C.
    Yang, James N.
    Tam, Alda L.
    Li, Jing
    Wang, Xin A.
    Zhao, Zhongxiang
    McRae, Stephen E.
    Settle, Stephen H.
    Rhines, Laurence D.
    Chang, Eric L.
    Brown, Paul D.
    Ghia, Amol J.
    JOURNAL OF RADIOSURGERY AND SBRT, 2016, 4 (01): : 7 - 14