Online verification of breath-hold reproducibility using kV-triggered imaging for liver stereotactic body radiation therapy

被引:3
|
作者
Guo, Bingqi [1 ,2 ]
Stephans, Kevin [1 ]
Woody, Neil [1 ]
Antolak, Alexander [1 ]
Moazzezi, Mojtaba [1 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Taussig Canc Inst, Dept Radiat Oncol, Cleveland, OH USA
[2] Cleveland Clin Fdn, Taussig Canc Inst, Dept Radiat Oncol, 9500 Euclid Ave,CA-50, Cleveland, OH 44195 USA
来源
关键词
breath-hold reproducibility; liver SBRT; triggered imaging; BEAM COMPUTED-TOMOGRAPHY; CONTROL ABC; GUIDANCE; RADIOTHERAPY; DIAPHRAGM; FEASIBILITY; PRECISION;
D O I
10.1002/acm2.14045
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To introduce a new technique for online breath-hold verification for liver stereotactic body radiation therapy (SBRT) based on kilovoltage-triggered imaging and liver dome positions. Material and Methods: Twenty-five liver SBRT patients treated with deep inspiration breath-hold were included in this IRB-approved study. To verify the breath-hold reproducibility during treatment, a KV-triggered image was acquired at the beginning of each breath-hold. The liver dome position was visually compared with the expected upper/lower liver boundaries created by expanding/contracting the liver contour 5 mm in the superior-inferior direction. If the liver dome was within the boundaries, delivery continued; otherwise, beam was held manually, and the patient was instructed to take another breath-hold until the liver dome fell within boundaries. The liver dome was delineated on each triggered image. The mean distance between the delineated liver dome to the projected planning liver contour was defined as liver dome position error e(dome). The mean and maximum e(dome) of each patient were compared between no breath-hold verification (all triggered images) and with online breath-hold verification (triggered images without beam-hold). Results: Seven hundred thirteen breath-hold triggered images from 92 fractions were analyzed. For each patient, an average of 1.5 breath-holds (range 0-7 for all patients) resulted in beam-hold, accounting for 5% (0-18%) of all breath-holds; online breath-hold verification reduced the mean e(dome) from 3.1 mm (1.3-6.1 mm) to 2.7 mm (1.2-5.2 mm) and the maximum e(dome) from 8.6 mm (3.0-18.0 mm) to 6.7 mm (3.0-9.0 mm). The percentage of breath-holds with e(dome) >5 mm was reduced from 15% (0-42%) without breath-hold verification to 11% (0-35%) with online breath-hold verification. online breath-hold verification eliminated breath-holds with e(dome) >10 mm, which happened in 3% (0-17%) of all breath-holds. Conclusion: It is clinically feasible to monitor the reproducibility of each breath-hold during liver SBRT treatment using triggered images and liver dome. Online breath-hold verification improves the treatment accuracy for liver SBRT.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Using kV Triggered Imaging and Liver Dome Position to Reduce the Dosimetric Error Caused by Breath Hold Variability for Liver Stereotactic Body Radiation Therapy
    Stephans, K. L.
    Woody, N. M.
    Xia, P.
    Guo, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : S179 - S179
  • [2] Verification of Breath-Hold Technique in Stereotactic Body Radiation Therapy for Lung Cancer: What Are the Optimal Margins?
    Okazaki, D.
    Murai, T.
    Nakajima, K.
    Kondo, T.
    Yanagi, T.
    Fukuma, H.
    Eguchi, Y.
    Kitagawa, H.
    Tuchiya, T.
    Hirose, Y.
    Shibamoto, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E706 - E707
  • [3] Verification of deep-inspiration breath-hold radiation therapy with respect to reproducibility.
    Freislederer, P.
    Heinz, C.
    Walter, F.
    Schoenecker, S.
    Parodi, K.
    Soehn, M.
    Belka, C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S107 - S107
  • [4] Split-VMAT technique to control the expiratory breath-hold time in liver stereotactic body radiation therapy
    Lin, Yen Hwa
    Ozawa, Shuichi
    Miura, Hideharu
    Yogo, Katsunori
    Nakashima, Takeo
    Miki, Kentaro
    Tsuda, Shintaro
    Ochi, Yusuke
    Kawahara, Daisuke
    Kimura, Tomoki
    Saito, Akito
    Nagata, Yasushi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 40 : 17 - 23
  • [5] Evaluation of Reproducibility and Stability of Deep Inspiration Breath-Hold in Lung Stereotactic Body Radiation Therapy Using a Real-Time Tumor-Tracking Radiation Therapy System
    Kawazoe, Y.
    Shiinoki, T.
    Fujimoto, K.
    Yuasa, Y.
    Mukaidani, W.
    Tanaka, H.
    MEDICAL PHYSICS, 2024, 51 (09) : 6641 - 6641
  • [6] Reproducibility of Target Position Using Moderate Voluntary Breath-Hold During Liver Stereotactic Ablative Radiotherapy
    Cui, G.
    Trakul, N.
    Chang, E.
    Shiu, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3612 - 3612
  • [7] Using Kilovoltage Triggered Imaging to Improve Intrafraction Motion Management for Free Breathing and Breath Hold Lung Stereotactic Body Radiation Therapy
    Moazzezi, M.
    Xia, P.
    Stephans, K.
    Guo, B.
    MEDICAL PHYSICS, 2022, 49 (06) : E973 - E974
  • [8] Patient Setup Management for Pancreatic Stereotactic Body Radiation Therapy: Interfraction Adjustment Between Spine Alignment and the Pancreatic Fiducial During Breath-Hold kV Imaging
    Forbang, R. Teboh
    Srinivasan, S.
    Ellsworth, S.
    Shin, E.
    Khashab, M.
    O'Broin-Lennon, A.
    Pawlik, T.
    Wolfgang, C.
    Laheru, D.
    Herman, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S364 - S364
  • [9] Pancreatic SABR using peritumoral fiducials, triggered imaging and breath-hold
    Kisivan, Katalin
    Farkas, Andrea
    Kovacs, Peter
    Glavak, Csaba
    Lukacs, Gabor
    Mahr, Karoly
    Szabo, Zsolt
    Csima, Melinda Petone
    Gulyban, Akos
    Toth, Zoltan
    Kaposztas, Zsolt
    Lakosi, Ferenc
    PATHOLOGY & ONCOLOGY RESEARCH, 2023, 29
  • [10] Verification of Target Volume Margin of Visual-Guided Breath-Hold Method in Stereotactic Body Radiotherapy for Liver Cancer
    Cho, M.
    Kim, H.
    Yoon, S.
    Jung, J.
    Lee, S.
    Kwak, J.
    Yoon, K.
    Jeong, C.
    Park, M.
    Kim, H.
    Kim, S.
    Cho, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E335 - E335