Synthetic bone graft versus autograft or allograft for spinal fusion: a systematic review

被引:122
|
作者
Buser, Zorica [1 ]
Brodke, Darrel S. [2 ]
Youssef, Jim A. [3 ]
Meisel, Hans-Joerg [4 ]
Myhre, Sue Lynn [3 ]
Hashimoto, Robin [5 ]
Park, Jong-Beom [6 ]
Yoon, S. Tim [7 ]
Wang, Jeffrey C. [1 ]
机构
[1] Univ Southern Calif, Keck Sch Med, Dept Orthopaed Surg, Los Angeles, CA 90033 USA
[2] Univ Utah, Sch Med, Dept Orthoped, Salt Lake City, UT USA
[3] Spine Colorado, Durango, CO USA
[4] Bergmannstrost Hosp, Dept Neurosurg, Halle, Germany
[5] Spectrum Res Inc, Tacoma, WA USA
[6] Catholic Univ Korea, Sch Med, Uijongbu St Marys Hosp, Dept Orthopaed Surg, Uijongbu, South Korea
[7] Emory Univ, Dept Orthoped, Emory Spine Ctr, Atlanta, GA 30322 USA
关键词
systematic review; synthetic graft; fusion; cervical; lumbar; randomized control trials; technique; POSTEROLATERAL LUMBAR FUSION; BETA-TRICALCIUM PHOSPHATE; MARROW ASPIRATE; CORALLINE HYDROXYAPATITE; CALCIUM-SULFATE; LOCAL-BONE; ILIAC CREST; FOLLOW-UP; HEALOS; SCOLIOSIS;
D O I
10.3171/2016.1.SPINE151005
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this review was to compare the efficacy and safety of synthetic bone graft substitutes versus autograft or allograft for the treatment of lumbar and cervical spinal degenerative diseases. Multiple major medical reference databases were searched for studies that evaluated spinal fusion using synthetic bone graft substitutes (either alone or with an autograft or allograft) compared with autograft and allograft. Randomized controlled trials (RCT) and cohort studies with more than 10 patients were included. Radiographic fusion, patient-reported outcomes, and functional outcomes were the primary outcomes of interest. The search yielded 214 citations with 27 studies that met the inclusion criteria. For the patients with lumbar spinal degenerative disease, data from 19 comparative studies were included: 3 RCTs, 12 prospective, and 4 retrospective studies. Hydroxyapatite (HA), HA+collagen, beta-tricalcium phosphate (beta-TCP), calcium sulfate, or polymethylmethacrylate (PMMA) were used. Overall, there were no differences between the treatment groups in terms of fusion, functional outcomes, or complications, except in 1 study that found higher rates of HA graft absorption. For the patients with cervical degenerative conditions, data from 8 comparative studies were included: 4 RCTs and 4 cohort studies (1 prospective and 3 retrospective studies). Synthetic grafts included HA, beta-TCP/HA, PMMA, and biocompatible osteoconductive polymer (BOP). The PMMA and BOP grafts led to lower fusion rates, and PMMA, HA, and BOP had greater risks of graft fragmentation, settling, and instrumentation problems compared with iliac crest bone graft. The overall quality of evidence evaluating the potential use and superiority of the synthetic biological materials for lumbar and cervical fusion in this systematic review was low or insufficient, largely due to the high potential for bias and small sample sizes. Thus, definitive conclusions or recommendations regarding the use of these synthetic materials should be made cautiously and within the context of the limitations of the evidence.
引用
收藏
页码:509 / 516
页数:8
相关论文
共 50 条
  • [31] Hamstring Autograft Versus Hybrid Graft for Anterior Cruciate Ligament Reconstruction: A Systematic Review
    Wang, Hong-De
    Gao, Shi-Jun
    Zhang, Ying-Ze
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2020, 48 (04): : 1014 - 1022
  • [32] Controversy in operative techniques for cervical spondylosis discectomy: Autograft versus allograft versus no graft
    Vishteh, AG
    Baskin, JJ
    Sonntag, VKH
    TECHNIQUES IN NEUROSURGERY, 1999, 5 (02): : 146 - 152
  • [33] Comparison of fusion outcomes of bone morphogenetics proteins-7 and bone autograft in posterolateral lumbar fusion: A systematic review
    Subagio, Eko Agus
    Rahmadhan, Mustaqim Apriyansa
    Faris, Muhammad
    Susilo, Rahardian Indarto
    Suroto, Nur Setiawan
    Utomo, Budi
    Wicaksono, Pandu
    Bajamal, Abdul Hafid
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2023, 33
  • [34] Allograft Versus Autograft in Posterior Cruciate Ligament Reconstruction: An Evidence-Based Systematic Review
    Hudgens, Joshua L.
    Gillette, Blake P.
    Krych, Aaron J.
    Stuart, Michael J.
    May, Jedediah H.
    Levy, Bruce A.
    JOURNAL OF KNEE SURGERY, 2013, 26 (02) : 109 - 115
  • [35] Autologous Bone Is Inferior to Alloplastic Cranioplasties: Safety of Autograft and Allograft Materials for Cranioplasties, a Systematic Review
    van de Vijfeijken, Sophie E. C. M.
    Munker, Tijmen J. A. G.
    Spijker, Rene
    Karssemakers, Luc H. E.
    Vandertop, William P.
    Becking, Alfred G.
    Ubbink, Dirk T.
    WORLD NEUROSURGERY, 2018, 117 : 443 - +
  • [36] The fusion rate of calcium sulfate with local autograft bone compared with autologous iliac bone graft for instrumented short-segment spinal fusion
    Chen, WJ
    Tsai, TT
    Chen, LH
    Niu, CC
    Lai, PL
    Fu, TS
    McCarthy, K
    SPINE, 2005, 30 (20) : 2293 - 2297
  • [37] Autograft and allograft bone chips interbody fusion for spondylodiscitis: Surgery outcomes
    Rezvani, Majid
    Zohrevand, Amirhosein
    Azimi, Parisa
    Fallahpour, Soheil
    Saghaei, Saeid
    Yazdanian, Taravat
    Pashnehtalaee, Mohammadjavad
    CASPIAN JOURNAL OF INTERNAL MEDICINE, 2023, 14 (01) : 133 - 137
  • [38] A meta-analysis of autograft versus allograft in anterior cervical fusion
    Floyd, T
    Ohnmeiss, D
    EUROPEAN SPINE JOURNAL, 2000, 9 (05) : 398 - 403
  • [39] Anterior Cervical Discectomy and Fusion in Professional Athletes Allograft Versus Autograft
    Hotchkiss, William R.
    Clavenna, Andrew L.
    Nimmons, Scott J. B.
    Dossett, Andrew B.
    CLINICAL SPINE SURGERY, 2022, 35 (09): : E680 - E684
  • [40] A meta-analysis of autograft versus allograft in anterior cervical fusion
    T. Floyd
    European Spine Journal, 2000, 9 : 398 - 403