Comparison of Vascular Responses Following New-Generation Biodegradable and Durable Polymer-Based Drug-Eluting Stent Implantation in an Atherosclerotic Rabbit Iliac Artery Model

被引:36
|
作者
Nakazawa, Gaku [1 ]
Torii, Sho [1 ]
Ijichi, Takeshi [1 ]
Nagamatsu, Hirofumi [1 ]
Ohno, Yohei [1 ]
Kurata, Fumi [1 ]
Yoshikawa, Ayako [1 ]
Nakano, Masataka [1 ]
Shinozaki, Norihiko [1 ]
Yoshimachi, Fuminobu [1 ]
Ikari, Yuji [1 ]
机构
[1] Tokai Univ, Sch Med, Dept Cardiol, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
来源
关键词
atherosclerosis; endothelialization; polymer; stent; BARE-METAL STENTS; MYOCARDIAL-INFARCTION; SPIRIT III; THROMBOSIS; RESTENOSIS; PATHOLOGY; TRIAL; PREDICTORS; MICRORNAS; HUMANS;
D O I
10.1161/JAHA.116.003803
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Incomplete endothelialization is the primary substrate of late stent thrombosis; however, recent reports have revealed that abnormal vascular responses are also responsible for the occurrence of late stent failure. The aim of the current study was to assess vascular response following deployment of biodegradable polymer-based Synergy (Boston Scientific) and Nobori (Terumo) drug-eluting stents and the durable polymer-based Resolute Integrity stent (Medtronic) in an atherosclerotic rabbit iliac artery model. Methods and Results-A total of 24 rabbits were fed an atherogenic diet, and then a balloon injury was used to induce atheroma formation. Synergy, Nobori, and Resolute Integrity stents were randomly implanted in iliac arteries. Animals were euthanized at 28 days for scanning electron microscopic evaluation and at 90 days for histological analysis. The percentage of uncovered strut area at 28 days was lowest with Synergy, followed by Resolute Integrity, and was significantly higher with Nobori stents (Synergy 1.1 +/- 2.2%, Resolute Integrity 2.0 +/- 3.9%, Nobori 4.6 +/- 3.0%; P< 0.001). At 90 days, inflammation score was lowest for Synergy (0.27 +/- 0.45), followed by Nobori (0.62 +/- 0.59), and was highest for Resolute Integrity (0.89 +/- 0.46, P< 0.001). Foamy macrophage infiltration within neointima (ie, neoatherosclerosis) was significantly less with Synergy (0.62 +/- 0.82) compared with Nobori (0.85 +/- 0.74) and Resolute Integrity (1.39 +/- 1.32; P=0.034). Conclusions-The biodegradable polymer-coated thin-strut Synergy drug-eluting stent showed the fastest stent strut neointimal coverage and the lowest incidence of neoatherosclerosis in the current animal model.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Long-Term Vascular Responses to Resolute® and Xience V® Polymer-Based Drug-Eluting Stents in a Rabbit Model of Atherosclerosis
    Hoymans, Vicky Y.
    Van Dyck, Christophe J.
    Haine, Steven E.
    Frederix, Geert
    Fransen, Erik
    Timmermans, Jean-Pierre
    Vrints, Christiaan J.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (04) : 381 - 390
  • [22] Comparison of biolimus-eluting stent with a biodegradable polymer with newest-generation drug-eluting stents with durable polymers in patients with acute myocardial infarction
    Cha, K. S.
    Jang, H. Y.
    Lee, H. W.
    Ahn, J. H.
    Oh, J. H.
    Choi, J. H.
    Lee, H. C.
    Park, J. S.
    Hong, T. J.
    Jeong, M. H.
    EUROPEAN HEART JOURNAL, 2013, 34 : 550 - 551
  • [23] VASCULAR RESPONSES TO DRUG-ELUTING STENTS WITH BIODEGRADABLE POLYMER VERSUS DURABLE POLYMER: AN OPTICAL COHERENCE TOMOGRAPHY SUBSTUDY OF THE NEXT
    Kubo, Takashi
    Akasaka, Takashi
    Ino, Yasushi
    Igarashi, Keiichi
    Kadota, Kazushige
    Kozuma, Ken
    Tanabe, Kengo
    Nakagawa, Yoshihisa
    Muramatsu, Toshiya
    Morino, Yoshihiro
    Kimura, Takeshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1771 - A1771
  • [24] Late neointimal volume reduction is observed following biodegradable polymer-based drug eluting stent in porcine model
    Ijichi, Takeshi
    Nakazawa, Gaku
    Torii, Sho
    Nagamatsu, Hirofumi
    Yoshikawa, Ayako
    Nakamura, Shintaro
    Souba, Junko
    Isobe, Atsushi
    Hagiwara, Hitomi
    Ikari, Yuji
    IJC HEART & VASCULATURE, 2021, 34
  • [25] Biodegradable-polymer-based drug-eluting stent for left main coronary artery disease
    Gutierrez-Chico, J. L.
    Jochheim, D.
    Mehilli, J.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (05): : 563 - 574
  • [26] Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable Polymer - Optical Coherence Tomography Substudy of the NEXT
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Fusazaki, Tetsuya
    Okura, Hiroyuki
    Shinke, Toshiro
    Ino, Yasushi
    Hasegawa, Takao
    Takashima, Hiroaki
    Takamisawa, Itaru
    Yamaguchi, Hiroshi
    Igarashi, Keiichi
    Kadota, Kazushige
    Tanabe, Kengo
    Nakagawa, Yoshihisa
    Muramatsu, Toshiya
    Morino, Yoshihiro
    Kimura, Takeshi
    CIRCULATION JOURNAL, 2014, 78 (10) : 2408 - 2414
  • [27] Temporal course of vascular healing and neoatherosclerosis after implantation of durable- or biodegradable-polymer drug-eluting stents
    Guagliumi, Giulio
    Shimamura, Kunihiro
    Sirbu, Vasite
    Garbo, Roberto
    Boccuzzi, Giacomo
    Vassileva, Angelina
    Valsecchi, Orazio
    Fiocca, Luigi
    Canova, Paolo
    Colombo, Francesco
    Pereira, Gabriel Tensot Rodriguez
    Nakamura, Daisuke
    Attizzani, Guitherme F.
    Cereda, Alberto
    Satogami, Keisuke
    De Luca, Eonardo
    Saia, Francesco
    Capodanno, Davide
    EUROPEAN HEART JOURNAL, 2018, 39 (26) : 2448 - +
  • [28] Outcomes of Acute Myocardial Infarction Patients Implanted With Biodegradable Polymer Biolimus-Eluting Stents Versus New-Generation Durable Polymer Drug-Eluting Stents: A Retrospective Analysis
    Choe, Jeong Cheon
    Cha, Kwang Soo
    Jang, Hye Yoon
    Choi, Jong Hyun
    Kim, Bo Won
    Ahn, Jinhee
    Park, Jin Sup
    Lee, Hye Won
    Oh, Jun-Hyok
    Choi, Jung Hyun
    Lee, Han Cheol
    Hong, Taek Jong
    Ahn, Youngkeun
    Jeong, Myung Ho
    ANGIOLOGY, 2017, 68 (08) : 698 - 706
  • [29] Ten-year clinical outcomes of polymer-free versus durable polymer new-generation drug-eluting stent in patients with coronary artery disease with and without diabetes mellitus
    Koch, Tobias
    Lenz, Tobias
    Joner, Michael
    Xhepa, Erion
    Koppara, Tobias
    Wiebe, Jens
    Coughlan, J. J.
    Aytekin, Alp
    Ibrahim, Tareq
    Kessler, Thorsten
    Cassese, Salvatore
    Laugwitz, Karl-Ludwig
    Schunkert, Heribert
    Kastrati, Adnan
    Kufner, Sebastian
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (10) : 1586 - 1598
  • [30] A polymer-free dual drug-eluting stent in patients with coronary artery disease: a randomized trial vs. polymer-based drug-eluting stents
    Byrne, Robert A.
    Mehilli, Julinda
    Iijima, Raisuke
    Schulz, Stefanie
    Pache, Juergen
    Seyfarth, Melchior
    Schoemig, Albert
    Kastrati, Adnan
    EUROPEAN HEART JOURNAL, 2009, 30 (08) : 923 - 931