Developing an Expert System to Improve Lesion Quantification for Personalized PET Imaging

被引:0
|
作者
Li, Yusheng [1 ]
Daube-Witherspoon, Margaret E. [1 ]
Matej, Samuel [1 ]
Metzler, Scott D. [1 ]
机构
[1] Univ Penn, Dept Radiol, 3620 Hamilton Walk, Philadelphia, PA 19104 USA
来源
2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2017年
基金
美国国家卫生研究院;
关键词
Terms Expert system; lesion embedding; local impulse response (LIR); image reconstruction; positron emission tomography (PET); RECONSTRUCTION; RESOLUTION; PRECISION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The measurements of lesion standardized uptake value (SUV) in clinical PET studies are affected in a complicated way by many aspects of the data, including-but not limited to-count level, lesion size, lesion shape, lesion location, background level and structure, and patient size. Optimized reconstruction algorithms and their parameters can provide substantial improvements in lesion quantification for personalized PET imaging. Full optimization of reconstruction parameters can be too complicated/tedious for human beings, thus we propose an expert system to optimize these parameters and to improve lesion quantification. Three core techniques are explored: 1) synthetic lesion embedding technique, 2) system local impulse response (LIR) modeling, and 3) bootstrapping for uncertainty estimation. We experimentally acquire list-mode data from physical radioactive spheres of known activity concentration with different sizes at different locations using the same PET scanner as was used for acquiring the patient data. We can then synthetically embed the spheres by merging the sphere list-mode data into patient data. We also use statistical bootstrapping method to generate multiple replicates of patient data with embedded lesions to determine the variance of the estimated SUV. We also use the LIR to characterize the local properties and responses of an imaging system, which can be used as a criterion for optimizing the reconstruction parameters. We have performed simulated phantom studies to confirm the use of bootstrapping of clinical data to determine the variance of SUV, and the use of LIR to determine the recovery coefficients and the bias of SUV of each lesion with different size. We are currently integrating the expert-system tools with a graphical user interface to allow the execution and visualization of ensembles of lesions with the use of different reconstruction algorithms and parameters. The end result will be patient- and lesion-specific corrected SUVs with estimated uncertainty.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] The effect of patient positioning aids on PET quantification in PET/MR imaging
    Frederic Mantlik
    Matthias Hofmann
    Matthias K. Werner
    Alexander Sauter
    Jürgen Kupferschläger
    Bernhard Schölkopf
    Bernd J. Pichler
    Thomas Beyer
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 920 - 929
  • [42] Validation of the lesion quantification of a learning-based PET image filter
    Meng, Xiangxi
    Wu, Runze
    Yang, Zhi
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [43] Data driven gated PET/CT: The implications for lesion quantification and segmentation
    Thomas, Allan
    Pan, Tinsu
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [44] A novel iterative method for lesion delineation and volumetric quantification with FDG PET
    van Dalen, Jorn A.
    Hoffmann, Aswin L.
    Dicken, Volker
    Vogel, Wouter V.
    Wiering, Bastiaan
    Ruers, Theo J.
    Karssemeijer, Nico
    Oyen, Wim J. G.
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (06) : 485 - 493
  • [45] An expert system to improve power system contingency analysis
    Jadid, S
    Rokni, MR
    ELECTRIC POWER SYSTEMS RESEARCH, 1997, 40 (01) : 37 - 43
  • [46] Developing an expert system for vehicle autotracking and positioning system
    Wu, WL
    Tangli
    Lin, XD
    He, RL
    Li, DY
    Tianping
    Zou, YW
    Yin, GF
    ICSP '96 - 1996 3RD INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, PROCEEDINGS, VOLS I AND II, 1996, : 1563 - 1569
  • [47] Developing a Contextually Personalized Hybrid Recommender System
    Bozanta, Aysun
    Kutlu, Birgul
    MOBILE INFORMATION SYSTEMS, 2018, 2018
  • [48] Optimization of PET system design for lesion detection
    Qi, JY
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1470 - 1476
  • [49] Nanoparticles for SPECT and PET Imaging: Towards Personalized Medicine and Theranostics
    Polyak, Andras
    Ross, Tobias L.
    CURRENT MEDICINAL CHEMISTRY, 2018, 25 (34) : 4328 - 4353
  • [50] Developing new molecular imaging probes for PET
    Serdons, Kim
    Verbruggen, Alfons
    Bormans, Guy M.
    METHODS, 2009, 48 (02) : 104 - 111