Developing an Expert System to Improve Lesion Quantification for Personalized PET Imaging

被引:0
|
作者
Li, Yusheng [1 ]
Daube-Witherspoon, Margaret E. [1 ]
Matej, Samuel [1 ]
Metzler, Scott D. [1 ]
机构
[1] Univ Penn, Dept Radiol, 3620 Hamilton Walk, Philadelphia, PA 19104 USA
来源
2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2017年
基金
美国国家卫生研究院;
关键词
Terms Expert system; lesion embedding; local impulse response (LIR); image reconstruction; positron emission tomography (PET); RECONSTRUCTION; RESOLUTION; PRECISION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The measurements of lesion standardized uptake value (SUV) in clinical PET studies are affected in a complicated way by many aspects of the data, including-but not limited to-count level, lesion size, lesion shape, lesion location, background level and structure, and patient size. Optimized reconstruction algorithms and their parameters can provide substantial improvements in lesion quantification for personalized PET imaging. Full optimization of reconstruction parameters can be too complicated/tedious for human beings, thus we propose an expert system to optimize these parameters and to improve lesion quantification. Three core techniques are explored: 1) synthetic lesion embedding technique, 2) system local impulse response (LIR) modeling, and 3) bootstrapping for uncertainty estimation. We experimentally acquire list-mode data from physical radioactive spheres of known activity concentration with different sizes at different locations using the same PET scanner as was used for acquiring the patient data. We can then synthetically embed the spheres by merging the sphere list-mode data into patient data. We also use statistical bootstrapping method to generate multiple replicates of patient data with embedded lesions to determine the variance of the estimated SUV. We also use the LIR to characterize the local properties and responses of an imaging system, which can be used as a criterion for optimizing the reconstruction parameters. We have performed simulated phantom studies to confirm the use of bootstrapping of clinical data to determine the variance of SUV, and the use of LIR to determine the recovery coefficients and the bias of SUV of each lesion with different size. We are currently integrating the expert-system tools with a graphical user interface to allow the execution and visualization of ensembles of lesions with the use of different reconstruction algorithms and parameters. The end result will be patient- and lesion-specific corrected SUVs with estimated uncertainty.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] PET quantification of artificial tissue bioreactor imaging
    Nemanich, Samuel
    Whitehead, Timothy
    Shoghi, Kooresh
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [32] Factors affecting quantification in PET/CT imaging
    Mawlawi, Osama
    Kappadath, S. Cheenu
    Pan, Tinsu
    Rohren, Eric
    Macapinlac, Homer A.
    CURRENT MEDICAL IMAGING, 2008, 4 (01) : 34 - 45
  • [34] EXPERT SYSTEM FOR ASIC IMAGING
    GUPTA, SN
    ARSHAK, KI
    MCDONNELL, P
    BOYCE, C
    DUGGAN, A
    OPTICAL/LASER MICROLITHOGRAPHY II, 1989, 1088 : 291 - 294
  • [35] Developing guidelines for pet rat housing through expert consultation
    Neville, Vikki
    Hunter, Kristina
    Benato, Livia
    Mendl, Michael
    Paul, Elizabeth S.
    VETERINARY RECORD, 2023, 192 (03) : no
  • [36] Lesion Quantification Accuracy of Digital 90Y PET Imaging in the Context of Dosimetry in Systemic FAPI Radionuclide Therapy
    Kersting, D.
    Jentzen, W.
    Jeromin, D.
    Mavroeidi, I.
    Conti, M.
    Buether, F.
    Herrmann, K.
    Rischpler, C.
    Hamacher, R.
    Fendler, W. P.
    Seifert, R.
    Costa, P. Fragoso
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S636 - S636
  • [37] Quantitative imaging of 124I with PET/CT in pretherapy lesion dosimetry Effects impairing image quantification and their corrections
    Jentzen, W.
    Freudenberg, L.
    Bockisch, A.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 55 (01): : 21 - 43
  • [38] A Phantom Design and Assessment of Lesion Detectability in PET Imaging
    Wollenweber, Scott D.
    Kinahan, Paul E.
    Alessio, Adam M.
    MEDICAL IMAGING 2017: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2017, 10136
  • [39] The effect of patient positioning aids on PET quantification in PET/MR imaging
    Mantlik, Frederic
    Hofmann, Matthias
    Werner, Matthias K.
    Sauter, Alexander
    Kupferschlaeger, Juergen
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    Beyer, Thomas
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (05) : 920 - 929
  • [40] PET/MR imaging of sarcomas: effect of PET quantification by classification of tissue
    Claes Nøhr Ladefoged
    Adam Espe Hansen
    Kim Francis Andersen
    Annika Loft
    Liselotte Højgaard
    Andreas Kjær
    Flemming Andersen
    EJNMMI Physics, 1 (Suppl 1)