Evaluation of a biosensor for the measurement of lactate in whole blood

被引:15
|
作者
de Keijzer, MH [1 ]
Brandts, RW [1 ]
Brans, PGW [1 ]
机构
[1] Univ Nijmegen St Radboud Hosp, Cent Lab Clin Chem, Nijmegen, Netherlands
关键词
lactate; biosensor; whole blood; spectrophotometry; plasma; activity; evaluation;
D O I
10.1016/S0009-9120(98)00105-2
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Evaluation of the analytical performance of a biosensor for the measurement of lactate in whole blood samples and comparison of the results of patients samples with a routinely used spectrophotometric enzymatic method. Design and Methods: Heparinized whole blood samples of patients and aqueous control samples were used to determine precision and carry-over. For comparison of the lactate biosensor and the enzymatic method human blood samples were split and measured. Results: Satisfactory within-run (n = 7) and day-to-day (n = 15) precision was found, while carry-over was minimal (<0.2%). A statistically significant relation between the lactate levels in whole blood samples (n = 31) and the corresponding plasma samples was round: y = 0.98x - 0.05 and r = 1.00. No correlation was found between the hematocrit (range 0.23-0.51) and the difference in lactate concentration between plasma and whole blood. When comparing patient results (n = 722) obtained with the spectrophotometric method and the biosensor method, the biosensor measured 13% higher lactate levels. A correction on the basis of the hematocrit minimized this difference. Conclusion: The combination of analytical performance, easy handling, rapid analysis, and measurement in whole blood makes the biosensor suitable for lactate STAT-analyses. Care must be given to the interpretation of the results as well as to the preanalytical aspects. Copyright (C) 1999 The Canadian Society of Clinical Chemists.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 50 条
  • [41] Design and evaluation of a portable optical-based biosensor for testing whole blood prothrombin time
    Yang, Chin-Lung
    Huang, Song-Jeng
    Chou, Cheng-Wei
    Chiou, Yan-Chao
    Lin, Kun-Piao
    Tsai, Min-Shiun
    Young, Kung-Chia
    TALANTA, 2013, 116 : 704 - 711
  • [42] THE MEASUREMENT OF AMMONIA IN WHOLE BLOOD
    ROSENOER, VM
    JOURNAL OF CLINICAL PATHOLOGY, 1959, 12 (02) : 128 - 130
  • [43] ACCURATE QUANTITATIVE ESTIMATION OF LACTATE IN WHOLE-BLOOD
    LIVESLEY, B
    ATKINSON, L
    CLINICAL CHEMISTRY, 1974, 20 (11) : 1478 - 1478
  • [44] Continuous ex vivo lactate monitoring in whole blood
    Gfrerer, RJ
    Wach, P
    Brunner, G
    Trajanoski, Z
    Schaupp, L
    Leitner, B
    Skrabal, F
    Jobst, G
    Moser, I
    Urban, G
    Schumacher, M
    Sendlhofer, G
    Pieber, TR
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2354 - 2356
  • [45] LACTATE AND PYRUVATE DETERMINATION IN 50 MUL WHOLE BLOOD
    TFELTHAN.P
    SIGGAARD.O
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1971, 27 (01): : 15 - &
  • [46] Concordance considerations for whole blood lactate measurements in sepsis
    Abou-Diwan, C.
    Said, J. S. H.
    Ramaswamy, M.
    CLINICA CHIMICA ACTA, 2019, 493 : S774 - S774
  • [47] LACTATE AND PYRUVATE LEVELS IN WHOLE-BLOOD AND PLASMA
    LEQUANG, NT
    LABROUSSE, J
    MERILLON, JP
    JACQUOT, C
    LISSAC, J
    NOUVELLE PRESSE MEDICALE, 1975, 4 (21): : 1598 - 1598
  • [48] Evaluation of the Accutrend for lactate measurement in dogs
    Stevenson, Connie K.
    Kidney, Beverly A.
    Duke, Tanya
    Snead, Elisabeth C. R.
    Jackson, Marion L.
    VETERINARY CLINICAL PATHOLOGY, 2007, 36 (03) : 261 - 266
  • [49] Novel Multiplexed Biosensor System for the Determination of Lactate and Pyruvate in Blood Serum
    Kucherenko, Ivan S.
    Soldatkin, Oleksandr O.
    Topolnikova, Yaroslava V.
    Dzyadevych, Sergei V.
    Soldatkin, Alexei P.
    ELECTROANALYSIS, 2019, 31 (08) : 1625 - 1631
  • [50] A protein biosensor for lactate
    D'Auria, S
    Gryczynski, Z
    Gryczynski, I
    Rossi, M
    Lakowicz, JR
    ANALYTICAL BIOCHEMISTRY, 2000, 283 (01) : 83 - 88