Evaluation of a biosensor for the measurement of lactate in whole blood

被引:15
|
作者
de Keijzer, MH [1 ]
Brandts, RW [1 ]
Brans, PGW [1 ]
机构
[1] Univ Nijmegen St Radboud Hosp, Cent Lab Clin Chem, Nijmegen, Netherlands
关键词
lactate; biosensor; whole blood; spectrophotometry; plasma; activity; evaluation;
D O I
10.1016/S0009-9120(98)00105-2
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Evaluation of the analytical performance of a biosensor for the measurement of lactate in whole blood samples and comparison of the results of patients samples with a routinely used spectrophotometric enzymatic method. Design and Methods: Heparinized whole blood samples of patients and aqueous control samples were used to determine precision and carry-over. For comparison of the lactate biosensor and the enzymatic method human blood samples were split and measured. Results: Satisfactory within-run (n = 7) and day-to-day (n = 15) precision was found, while carry-over was minimal (<0.2%). A statistically significant relation between the lactate levels in whole blood samples (n = 31) and the corresponding plasma samples was round: y = 0.98x - 0.05 and r = 1.00. No correlation was found between the hematocrit (range 0.23-0.51) and the difference in lactate concentration between plasma and whole blood. When comparing patient results (n = 722) obtained with the spectrophotometric method and the biosensor method, the biosensor measured 13% higher lactate levels. A correction on the basis of the hematocrit minimized this difference. Conclusion: The combination of analytical performance, easy handling, rapid analysis, and measurement in whole blood makes the biosensor suitable for lactate STAT-analyses. Care must be given to the interpretation of the results as well as to the preanalytical aspects. Copyright (C) 1999 The Canadian Society of Clinical Chemists.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 50 条
  • [21] STABILIZATION OF WHOLE-BLOOD LACTATE
    POWELL, JFN
    CLINICA CHIMICA ACTA, 1974, 55 (01) : 107 - 109
  • [22] Development and evaluation of an electrochemical biosensor for creatinine quantification in a drop of whole human blood
    Alvarez Menendez, Gabriel Alvarez
    Amor-Gutierrez, Olaya
    Costa Garcia, Agustin
    Funes-Menendez, Maria
    Prado, Catuxa
    Miguel, Diego
    Rodriguez-Gonzalez, Pablo
    Gonzalez-Gago, Adriana
    Garcia Alonso, J. Ignacio
    CLINICA CHIMICA ACTA, 2023, 543
  • [23] Comparison of an electrochemical biosensor with optical devices for hemoglobin measurement in human whole blood samples
    Hsieh, Ming-Song
    Wu, Tai-Guang
    Su, Chein-Shyong
    Cheng, Wen-Jing
    Ozbek, Namik
    Tsai, Kun-Yuan
    Lin, Ching-Yu
    CLINICA CHIMICA ACTA, 2011, 412 (23-24) : 2150 - 2156
  • [24] A Peptide-Based Electrochemical Biosensor for Facile Measurement of Whole-Blood Heparin
    Meng, Fanyu
    Liang, Weiguo
    Sun, Haixuan
    Wu, Ligang
    Gong, Xiao
    Miao, Peng
    CHEMELECTROCHEM, 2017, 4 (03): : 472 - 475
  • [25] Minimal-fouling enzyme electrode for continuous flow measurement of whole blood lactate
    Kyrolainen, M
    Hakanson, H
    Mattiasson, B
    Vadgama, P
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (11): : 1073 - 1081
  • [26] LACTATE MEASUREMENT - PLASMA OR BLOOD
    KRUSE, JA
    CARLSON, RW
    INTENSIVE CARE MEDICINE, 1990, 16 (01) : 1 - 2
  • [27] UREA AND LACTATE DETERMINED IN 1-MU-L WHOLE-BLOOD SAMPLES WITH A MINIATURIZED THERMAL BIOSENSOR
    XIE, B
    HARBORN, U
    MECKLENBURG, M
    DANIELSSON, B
    CLINICAL CHEMISTRY, 1994, 40 (12) : 2282 - 2287
  • [28] Evaluation of the Lactate Pro blood lactate analyser
    David B. Pyne
    Tanya Boston
    David T. Martin
    Andrew Logan
    European Journal of Applied Physiology, 2000, 82 : 112 - 116
  • [29] EVALUATION OF A METHOD FOR MEASUREMENT OF CYCLOSPORINE IN WHOLE-BLOOD BY HPLC
    BINDER, SR
    KEENAN, D
    REGALIA, MJ
    BIAGGI, M
    CLINICAL BIOCHEMISTRY, 1987, 20 (04) : 299 - 299
  • [30] Evaluation of the Lactate Pro blood lactate analyser
    Pyne, DB
    Boston, T
    Martin, DT
    Logan, A
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 82 (1-2) : 112 - 116