Molten Steel Level Measurement Based on Temperature Attenuation Characteristic

被引:6
|
作者
Xie, Zhi [1 ]
Su, Zhiqi [1 ]
He, Qing [1 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Liaoning, Peoples R China
关键词
adhesion thickness; temperature attenuation; maximum curvature time; molten steel level; VESSEL VIBRATION; TUNDISH;
D O I
10.2355/isijinternational.ISIJINT-2016-232
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
This paper proposes a molten steel level measuring method in a tundish. This method is based on the temperature attenuation characteristic of the temperature tube. Our previous work focused on the temperature distribution of the temperature tube which can be used for molten steel level measurement. In some continuous casters, sticky slag adheres to the tube, thus, blocking the temperature information on the tube. To avoid this problem of lacking true temperature, we analyzed the principle of adhesion and conclude that the adhesive slag thickness of the tube is influenced by whether that part of the tube contacts the slag or the molten steel prior to being lifted. Consequently, for detecting the adhesive slag thickness online with available pyrometer, a heat transfer model is established. Through analysis of the model, it was revealed that the thickness of the adhesive slag remarkably influences the measurable maximum curvature time of the temperature attenuation. In addition, this maximum curvature time is insensitive to other irrelevant factors such as initial temperature and ambient temperature. Therefore, the maximum curvature time of the temperature attenuation of the adhesive slag indirectly indicates the molten steel level. Finally, the experiments prove the feasibility and the sound accuracy of this method with the maximal error being 3 mm. This method is not only suited for the molten steel level measurement, but also applicable to other non-destructive measurement of coating layer thickness.
引用
收藏
页码:2208 / 2213
页数:6
相关论文
共 50 条
  • [41] ULTRASONIC ATTENUATION IN CARBON STEEL AND STAINLESS STEEL AT ELEVATED TEMPERATURE
    DARBARI, GS
    SINGH, RP
    VERMA, GS
    JOURNAL OF APPLIED PHYSICS, 1968, 39 (05) : 2238 - &
  • [42] End temperature prediction of molten steel in RH based on integrated case-based reasoning
    Feng K.
    Xu A.-J.
    He D.-F.
    Wang H.-B.
    Feng, Kai (fengkai-show@163.com), 2018, Science Press (40): : 161 - 167
  • [43] Design of Molten Steel Liquid Level Detecting System Based on Eddy Current Testing
    Wang Yifeng
    Gu Zhiqiang
    Deng Xin
    Wang Junpeng
    Qiao Dawei
    Lu Tianqi
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 10271 - 10274
  • [44] Molten Steel Level Controller Based on Disturbance Observer with Time-delay Compensation
    Kim, Minsung
    Moon, Sungwoong
    Na, Changheum
    You, Byungyong
    Kueon, Yeongsub
    Lee, Dukman
    Lee, Jookang
    Lee, Jin S.
    ISIJ INTERNATIONAL, 2011, 51 (02) : 256 - 261
  • [45] H∞ control of molten steel level in continuous caster
    Kitada, H
    Konda, O
    Kusachi, H
    Sasame, K
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 1998, 6 (02) : 200 - 207
  • [46] Robust molten steel level control for continuous casting
    Asano, K
    Kaji, T
    Aoki, H
    Ibaraki, M
    Moriwaki, S
    PROCEEDINGS OF THE 35TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-4, 1996, : 1245 - 1250
  • [47] DIRECT MEASUREMENT OF MANGANESE IN MOLTEN STEEL WITH AN ELECTROCHEMICAL PROBE
    ECKFELDT, EL
    TAYLOR, RM
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1975, 122 (03) : C98 - C98
  • [48] Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants
    Sanga, Ramesh
    Agarwal, Sourabh
    Sivaramakrishna, M.
    Rao, G. Prabhakara
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (04):
  • [49] An Integration Model for Converter Molten Steel End Temperature Prediction Based on Bayesian Formula
    Feng, Kai
    Yang, Lingzhi
    Su, Buxin
    Feng, Wei
    Wang, Longfei
    STEEL RESEARCH INTERNATIONAL, 2022, 93 (02)
  • [50] Temperature Measurement Method for Blast Furnace Molten Iron Based on Infrared Thermography and Temperature Reduction Model
    Pan, Dong
    Jiang, Zhaohui
    Chen, Zhipeng
    Gui, Weihua
    Xie, Yongfang
    Yang, Chunhua
    SENSORS, 2018, 18 (11)