Evaluation of thoracic pedicle morphometry in a Chinese population using 3D reformatted CT

被引:15
|
作者
Zhuang, Zerui [1 ]
Xie, Zeyu [2 ]
Ding, Shan [2 ]
Chen, Yuchun [1 ]
Luo, Jianmin [2 ]
Wang, Xinjia [1 ]
Kong, Kangmei [1 ]
机构
[1] Shantou Univ, Coll Med, Affiliated Hosp 2, Dept Orthoped Surg, Shantou 515041, Guangdong, Peoples R China
[2] Shantou Univ, Coll Med, Affiliated Hosp 2, Dept Neurosurg, Shantou 515041, Guangdong, Peoples R China
关键词
thoracic pedicle; morphometry; transpedicular fixation; reformatted CT; Chinese; TRANSPEDICULAR SCREW FIXATION; LUMBAR VERTEBRAL PEDICLES; BONE-MINERAL DENSITY; SPINAL DEFORMITIES; PLACEMENT; SAFETY; ACCURACY; DIAMETER; INSTRUMENTATION; HOOKS;
D O I
10.1002/ca.21265
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The aim of this study was to investigate the detailed three-dimensional morphology of the pedicles from T1 to T12 in 120 Chinese patients using a light-speed Vct CT (General Electric). After reformatting the original images, the following parameters were studied: outer pedicle width (OPW), outer pedicle height (OPH), pedicle chord length (PCL), pedicle cortical thickness (PCT) of the isthmus, and transverse pedicle angle (TPA). The mean outer pedicle width, outer pedicle height, and pedicle chord length were significantly smaller in females than in males at all levels (P < 0.01). The percentage of outer pedicle width =5.0 mm and =4.5 mm was high at mid-thoracic pedicles. No significant differences were found in transverse pedicle angle and pedicle cortical thickness in males and females. Pedicle cortical thickness was significantly thinner in patients over 50 years old compared with patients below 50 years old at most levels. The results showed that a screw of larger than 4.5 mm would be too large for mid-thoracic segments in Chinese population, especially for female patients. Considering the amount of variation between individuals and the complicated structure of the thoracic pedicles, the use of the transpedicular screw fixation must be individualized for each patient and based on detailed preoperative assessment. Reformatted CT assessment is essential before this procedure is performed. Clin. Anat. 25:461467, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:461 / 467
页数:7
相关论文
共 50 条
  • [31] Reliability of medial temporal lobe volume measurements using reformatted 3D images
    Bartzokis, G
    Altshuler, LL
    Greider, T
    Curran, J
    Keen, B
    Dixon, WJ
    [J]. PSYCHIATRY RESEARCH-NEUROIMAGING, 1998, 82 (01) : 11 - 24
  • [32] Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
    Nora Conrads
    Jan-Peter Grunz
    Henner Huflage
    Karsten Sebastian Luetkens
    Philipp Feldle
    Katharina Grunz
    Stefan Köhler
    Thomas Westermaier
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3007 - 3013
  • [33] Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
    Conrads, Nora
    Grunz, Jan-Peter
    Huflage, Henner
    Luetkens, Karsten Sebastian
    Feldle, Philipp
    Grunz, Katharina
    Koehler, Stefan
    Westermaier, Thomas
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3007 - 3013
  • [34] Role of 3D CT in the Evaluation of Craniosynostosis
    Buckler, M.
    Wu, L.
    Nguyen, V.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [35] Quantitative vertebral morphometry in 3D
    Stern, Darko
    Njagulj, Vesna
    Likar, Bostjan
    Pernus, Franjo
    Vrtovec, Tomaz
    [J]. MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [36] 3D CT cinematic rendering of pediatric thoracic vascular anomalies
    Recht, Hannah S.
    Weisberg, Edmund M.
    Fishman, Elliot K.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 10
  • [37] Thoracic cavity definition for 3D PET/CT analysis and visualization
    Cheirsilp, Ronnarit
    Bascom, Rebecca
    Allen, Thomas W.
    Higgins, William E.
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 62 : 222 - 238
  • [38] CT-Based Evaluation of the Shape of the Diaphragm Using 3D Slicer
    Taton, Olivier
    Van Muylem, Alain
    Leduc, Dimitri
    Gevenois, Pierre Alain
    [J]. JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, 37 (04): : 1980 - 1990
  • [39] Longitudinal 3D Morphometry Study using the Optimal Mass Transport
    Gao, Yi
    Tannenbaum, Allen
    [J]. MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [40] Utility of 3D reformatted images in the diagnosis of sternoclavicular joint injury
    Dennis Heaton
    Yang Wang
    Brittany Moore
    Luke Frager
    Brian M. Everist
    Jamie Crist
    [J]. Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 741 - 745