Changes in intracuff pressure of a cuffed endotracheal tube during prolonged surgical procedures

被引:27
|
作者
Kako, Hiromi [1 ,2 ]
Goykhman, Anatoliy [3 ]
Ramesh, Archana S. [1 ]
Krishna, Senthil G. [1 ,2 ]
Tobias, Joseph D. [1 ,2 ,4 ]
机构
[1] Nationwide Childrens Hosp, Dept Anesthesiol & Pain Med, Columbus, OH 43205 USA
[2] Ohio State Univ, Dept Anesthesiol & Pain Med, Columbus, MS USA
[3] Ohio Univ, Heritage Coll Osteopath Med, Athens, GA USA
[4] Ohio State Univ, Dept Pediat, Columbus, MS USA
关键词
Airway management; Intraoperative monitoring; Intubation; Endotracheal; Pediatrics; TRACHEAL TUBES; CHILDREN; ANESTHESIA; INFANTS;
D O I
10.1016/j.ijporl.2014.11.017
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: With the introduction of redesigned cuffed endotracheal tubes (ETTs), there has been an increasing trend toward their use in pediatric patients. Despite improvements in design, an unintended and prolonged hyperinflation of the cuff can compromise tracheal mucosal perfusion. The current study prospectively monitors changes in intracuff pressure continuously in pediatric patients undergoing prolonged surgical procedures. Methods: The study was conducted on pediatric patients who were scheduled to undergo prolonged surgical procedures (more than 4 h) with a cuffed ETT. After placement of the cuffed ETT, the cuff was inflated using the air-leak test with a CPAP of 20 cmH(2)O in the anesthesia circuit. After inflation, the inflating port of the pilot balloon was connected to the transducer of the invasive pressure monitoring device using our previously described technique to continuously measure the intracuff pressure. Measurements were recorded every 15 min for the first 1 h, and then every 30 min throughout the surgical procedure. Results: The study cohort included 30 patients who ranged in age from 1.2 to 17.6 years and in weight from 9.4 to 113.4 kg. There were 16 boys and 14 girls. The size of the cuffed ETT ranged from 3.5 mm to 8.0 mm ID. The baseline intracuff pressure at the time of inflation was 17.6 +/- 8.8 cmH(2)O. The absolute change in the intraoperative intracuff pressure when compared to the baseline intracuff pressure ranged from -25.8 to +16.3 cmH(2)O. In 9 patients (30%), the decrease of the intracuff pressure was >= 10 cmH(2)O. In 6 patients (20%), the increase of the intracuff pressure was >= 10 cmH(2)O. In 5 of 30 patients (17%), the absolute intracuff pressure was greater than 30 cmH(2)O at least once intraoperatively. In no patient, did the intracuff pressure remain the same as the baseline throughout the procedure. Conclusion: We noted significant variations in the intracuff pressure during prolonged surgical procedures. These unintended changes, both increases and decreases, may impact the perioperative course of patients. Our study suggests the need for continuously monitoring intracuff pressure if a cuffed ETT is used in children for prolonged surgical procedures. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:76 / 79
页数:4
相关论文
共 50 条
  • [1] Cuffed endotracheal tubes in children: the effect of the size of the cuffed endotracheal tube on intracuff pressure
    Krishna, Senthil G.
    Hakim, Mumin
    Sebastian, Roby
    Dellinger, Heather L.
    Tumin, Dmitry
    Tobias, Joseph D.
    PEDIATRIC ANESTHESIA, 2017, 27 (05) : 494 - 500
  • [2] Changes in intracuff pressure of a cuffed endotracheal tube during surgery for congenital heart disease using cardiopulmonary bypass
    Kako, Hiromi
    Alkhatib, Omar
    Krishna, Senthil G.
    Khan, Sarah
    Naguib, Aymen
    Tobias, Joseph D.
    PEDIATRIC ANESTHESIA, 2015, 25 (07) : 705 - 710
  • [3] Endotracheal Tube Intracuff Pressure During Helicopter Transport
    Bassi, Marco
    Zuercher, Mathias
    Erne, Jean-Jacques
    Ummenhofer, Wolfgang
    ANNALS OF EMERGENCY MEDICINE, 2010, 56 (02) : 89 - 93
  • [4] Changes in intracuff pressure of cuffed endotracheal tubes while positioning for adenotonsillectomy in children
    Olsen, Griffin H.
    Krishna, Senthil G.
    Jatana, Kris R.
    Elmaraghy, Charles A.
    Ruda, James M.
    Tobias, Joseph D.
    PEDIATRIC ANESTHESIA, 2016, 26 (05) : 500 - 503
  • [5] Endotracheal Tube Intracuff Pressure During Helicopter Transport
    Bessereau, Jacques
    Coulange, Mathieu
    Jacquin, Laurent
    Fournier, Marc
    Michelet, Pierre
    ANNALS OF EMERGENCY MEDICINE, 2010, 56 (05) : 583 - 584
  • [6] Endotracheal Tube Intracuff Pressure During Helicopter Transport Reply
    Bassi, Marco
    Zuercher, Mathias
    Ummenhofer, Wolfgang
    ANNALS OF EMERGENCY MEDICINE, 2010, 56 (05) : 584 - 584
  • [7] Endotracheal tube intracuff pressure in the pediatric population
    Wang, Xie
    Tan, Ling
    PEDIATRIC ANESTHESIA, 2014, 24 (09) : 1015 - 1016
  • [8] Measuring endotracheal tube intracuff pressure: no room for complacency
    Chandra M. Kumar
    Edwin Seet
    Tom C. R. V. Van Zundert
    Journal of Clinical Monitoring and Computing, 2021, 35 : 3 - 10
  • [9] Aspects of in vivo endotracheal tube intracuff pressure in cats
    Bird, Alice R.
    Bird, David J.
    McMillan, Matthew W.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2019, 46 (01) : 55 - 63
  • [10] Cuffed endotracheal tubes in infants and children: A technique to continuously measure the intracuff pressure
    Gopalakrishnan, Senthil
    Barry, N'Diris
    Rice, Julie
    Tobias, Joseph D.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2013, 77 (07) : 1135 - 1138