Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection

被引:60
|
作者
Zhao, Yang [1 ]
Yin, Henghui [2 ]
Chen, Yitian [1 ]
Wang, Mian [1 ]
Zheng, Liang [1 ]
Li, Zilun [1 ]
Chang, Guangqi [1 ]
机构
[1] Sun Yat Sen Univ, Vasc Surg Dept, Affiliated Hosp 1, 58 Zhongshan Two Rd, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Vasc Surg Dept, Affiliated Hosp 3, Guangzhou, Guangdong, Peoples R China
关键词
EUROPEAN REGISTRY; FALSE LUMEN; PLACEMENT; EXPERIENCE; MANAGEMENT; ANEURYSMS; DEVICES;
D O I
10.1016/j.jvs.2017.04.066
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Distal stent graft-induced new entry (SINE) can occur after thoracic endovascular aortic repair (TEVAR) of type B aortic dissection. This study investigated the mechanism of distal SINE and its prevention using a restrictive bare stent (RBS) technique. Methods: From January 2013 to December 2014, 68 consecutive type B aortic dissection patients received endovascular repair at our center. The RBS technique was used with distal oversizing (between the diameter of the thoracic stent graft and the descending aorta true lumen diameter at the level of the intended distal edge of the thoracic stent graft) > 20%. Results: Twenty-three patients received TEVAR with a single thoracic stent graft (TEVAR group, n = 23); the rest received TEVAR combined with the RBS technique (TEVAR thorn RBS group, n = 45). Four distal SINEs occurred in the TEVAR group. Distal oversizing (69.7% 6 35.5% vs 31.2% 6 24.5%; P = .005) and expansion mismatch ratio (132.2% 6 16.9% vs 106.5% 6 11.6%; P <.05) were significantly higher in the SINE patients. Compared with standard TEVAR, TEVAR thorn RBS was associated with significantly lower distal oversizing (TEVAR vs TEVAR thorn RBS group, 59.8% 6 24.7% vs 16.7% 6 7.6%; P <.05), lower expansion mismatch ratio (113.8% 6 14.6% vs 103.8% 6 11.7%; P = .012), and lower distal SINE rate (4/23 [17.4%] vs 0/45 [0%]; P = .011). Compared with the TEVAR group, the false lumen was reduced significantly at the level of the RBS distal edge (P = .029). Conclusions: Excessive distal oversizing and distal expansion mismatch ratio may contribute to the occurrence of distal SINE. The RBS technique reduced the incidence of distal SINE. Based on our midterm and long-term observations, implantation of an RBS may improve aortic remodeling.
引用
收藏
页码:93 / 103
页数:11
相关论文
共 50 条
  • [31] A S-Shaped Association of Distal Oversizing Ratio with Distal Stent-Graft-Induced New Entry Following Thoracic Endovascular Aortic Repair for Stanford B Aortic Dissection
    Liu, Feng
    Ge, Yangyang
    Rong, Dan
    Xue, Yan
    Fan, Weidong
    Miao, Jianhang
    Ge, Xiaohu
    Zhao, Zengren
    Guo, Wei
    ANNALS OF VASCULAR SURGERY, 2021, 77 : 54 - 62
  • [32] Risk factors for distal stent graft-induced new entry in type B aortic dissections: Systematic review and meta-analysis
    D'cruz, Reuban T.
    Syn, Nicholas
    Wee, Ian
    Choong, Andrew M. T. L.
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : 1682 - +
  • [33] PETTICOAT Technique to Prevent Distal Stent Graft-Induced New Entry Tears
    Civilini, Efrem
    ANNALS OF THORACIC SURGERY, 2017, 103 (06): : 2023 - 2023
  • [34] Hemodynamic parameters impact the stability of distal stent graft-induced new entry
    Wang, Kaihong
    Armour, Chloe H.
    Ma, Tao
    Dong, Zhihui
    Xu, Xiao Yun
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [35] Hemodynamic parameters impact the stability of distal stent graft-induced new entry
    Kaihong Wang
    Chlӧe H. Armour
    Tao Ma
    Zhihui Dong
    Xiao Yun Xu
    Scientific Reports, 13
  • [36] Numerical simulation of the distal stent graft-induced new entry after TEVAR
    Li, Meixuan
    Ma, Tao
    Cai, Yunhan
    Li, Jianming
    Meng, Zhuangyuan
    Dong, Zhihui
    Wang, Shengzhang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (05)
  • [37] Aortic intimal intussusception induced by stent-graft during endovascular repair of acute type B aortic dissection
    Li, Jiehua
    Li, Quanming
    Shu, Chang
    EUROPEAN HEART JOURNAL, 2023, 44 (45) : 4813 - 4813
  • [38] Biomechanical mechanism of distal stent-graft-induced new entry deterioration after thoracic endovascular aortic repair
    Qiao, Yonghui
    Luan, Jingyang
    Mao, Le
    Fan, Jianren
    Zhu, Ting
    Luo, Kun
    PHYSICS OF FLUIDS, 2022, 34 (10)
  • [39] Distal Pseudoaneurysm due to Late Stent Graft-Induced New Entry After Thoracic Endovascular Aortic Repair With Bolton Endograft: A Single-Center Analysis
    Franzese, Ilaria
    Petrilli, Giuseppe
    Giambruno, Vincenzo
    Puppini, Giovanni
    Faggian, Giuseppe
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (05) : E145 - E145
  • [40] Open Surgery with Frozen Elephant Trunk for the Treatment of Proximal Stent Graft-Induced New Entry in Type B Aortic Dissection: A Case Report
    Ren, Changwei
    Xu, Shangdong
    Lai, Yongqiang
    Zheng, Jun
    Sun, Lizhong
    ANNALS OF VASCULAR SURGERY, 2015, 29 (06) : 1316.e21 - 1316.e24