Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection

被引:60
|
作者
Zhao, Yang [1 ]
Yin, Henghui [2 ]
Chen, Yitian [1 ]
Wang, Mian [1 ]
Zheng, Liang [1 ]
Li, Zilun [1 ]
Chang, Guangqi [1 ]
机构
[1] Sun Yat Sen Univ, Vasc Surg Dept, Affiliated Hosp 1, 58 Zhongshan Two Rd, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Vasc Surg Dept, Affiliated Hosp 3, Guangzhou, Guangdong, Peoples R China
关键词
EUROPEAN REGISTRY; FALSE LUMEN; PLACEMENT; EXPERIENCE; MANAGEMENT; ANEURYSMS; DEVICES;
D O I
10.1016/j.jvs.2017.04.066
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Distal stent graft-induced new entry (SINE) can occur after thoracic endovascular aortic repair (TEVAR) of type B aortic dissection. This study investigated the mechanism of distal SINE and its prevention using a restrictive bare stent (RBS) technique. Methods: From January 2013 to December 2014, 68 consecutive type B aortic dissection patients received endovascular repair at our center. The RBS technique was used with distal oversizing (between the diameter of the thoracic stent graft and the descending aorta true lumen diameter at the level of the intended distal edge of the thoracic stent graft) > 20%. Results: Twenty-three patients received TEVAR with a single thoracic stent graft (TEVAR group, n = 23); the rest received TEVAR combined with the RBS technique (TEVAR thorn RBS group, n = 45). Four distal SINEs occurred in the TEVAR group. Distal oversizing (69.7% 6 35.5% vs 31.2% 6 24.5%; P = .005) and expansion mismatch ratio (132.2% 6 16.9% vs 106.5% 6 11.6%; P <.05) were significantly higher in the SINE patients. Compared with standard TEVAR, TEVAR thorn RBS was associated with significantly lower distal oversizing (TEVAR vs TEVAR thorn RBS group, 59.8% 6 24.7% vs 16.7% 6 7.6%; P <.05), lower expansion mismatch ratio (113.8% 6 14.6% vs 103.8% 6 11.7%; P = .012), and lower distal SINE rate (4/23 [17.4%] vs 0/45 [0%]; P = .011). Compared with the TEVAR group, the false lumen was reduced significantly at the level of the RBS distal edge (P = .029). Conclusions: Excessive distal oversizing and distal expansion mismatch ratio may contribute to the occurrence of distal SINE. The RBS technique reduced the incidence of distal SINE. Based on our midterm and long-term observations, implantation of an RBS may improve aortic remodeling.
引用
收藏
页码:93 / 103
页数:11
相关论文
共 50 条
  • [21] Early Prediction of Distal Stent Graft-Induced New Entry after Thoracic Endovascular Aortic Repair with Computational Fluid Dynamics
    School of Medical Technology, Beijing Institute of Technology, China
    ACM Int. Conf. Proc. Ser., 1600, (84-90):
  • [22] Thoracic Endovascular Aortic Repair of Highly Tapered Type B Aortic Dissection with Proximal Tapered Stent Grafts and Distal Restrictive Stent Grafts
    Niu, Liyuan
    Bao, Xia
    Yu, Wenjuan
    Li, Changfeng
    Wu, Jiang
    Yan, Junwei
    Xin, Hai
    Wang, Haofu
    Wang, Yuewei
    ANNALS OF VASCULAR SURGERY, 2022, 86 : 380 - 388
  • [23] Distal aortic arch aneurysm after endovascular stent graft repair for type B chronic aortic dissection
    Russo, CF
    Garatti, A
    Puttini, M
    Vitali, E
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (04): : 634 - 636
  • [24] Endovascular Stent Graft Repair of Aortic Dissection Type B Extending to the Aortic Arch
    Lu, Q.
    Jing, Z.
    Zhao, Z.
    Bao, J.
    Feng, X.
    Feng, R.
    Mei, Z.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 42 (04) : 456 - 463
  • [25] Endovascular repair of type B aortic dissection with the restrictive bare stent technique: morphologic changes, technique details, and outcomes
    Zhau, Binshan
    Xu, Geliang
    Zhu, Huagang
    Xie, Wentao
    Zhang, Zhigong
    Li, Yongsheng
    Qiu, Peng
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2018, 14 : 1993 - 2002
  • [26] Distal Stent Graft-Induced New Entry after Total Arch Replacement with Frozen Elephant Trunk for Aortic Dissection
    Nomura, Yoshikatsu
    Tonoki, Shuto
    Kawashima, Motoharu
    Fujisue, Jun
    Uchino, Gaku
    Miyahara, Shunsuke
    Tanaka, Hiroshi
    Honda, Tasuku
    Mukohara, Nobuhiko
    Murakami, Hirohisa
    ANNALS OF VASCULAR DISEASES, 2021, 14 (04) : 362 - 367
  • [27] Predictive factors of distal stent graft-induced new entry after frozen elephant trunk procedure for aortic dissection
    Hiraoka, Arudo
    Iida, Yasunori
    Furukawa, Tomokuni
    Ueki, Chikara
    Miyake, Koichi
    Mieno, Makiko
    Okamura, Homare
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (01)
  • [28] Thoracic Aortic Aneurysm Expansion Due to Late Distal Stent Graft-Induced New Entry
    Janosi, Rolf Alexander
    Tsagakis, Konstantinos
    Bettin, Markus
    Kahlert, Philipp
    Horacek, Michael
    Al-Rashid, Fadi
    Schlosser, Thomas
    Jakob, Heinz
    Eggebrecht, Holger
    Erbel, Raimund
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (02) : E43 - E53
  • [29] Early Experience With a Novel Dissection-Specific Stent-Graft to Prevent Distal Stent-Graft-Induced New Entry Tears After Thoracic Endovascular Repair of Chronic Type B Aortic Dissections
    Burdess, Anne
    D'Oria, Mario
    Mani, Kevin
    Tegler, Gustaf
    Lindstrom, David
    Mogensen, John
    Koelbel, Tilo
    Wanhainen, Anders
    ANNALS OF VASCULAR SURGERY, 2022, 81 : 36 - 47
  • [30] Risk factors for distal stent graft-induced new entry after frozen elephant trunk procedure in chronic aortic dissection
    Akita, Sho
    Tokuda, Yoshiyuki
    Narita, Yuji
    Terazawa, Sachie
    Yoshizumi, Tomo
    Ito, Hideki
    Mutsuga, Masato
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2025,