Design and development of portable fluorescence reader using Silicon photomultiplier (SiPM) sensor

被引:4
|
作者
Makkar, Roshan Lal [1 ,2 ]
Aliya, Sana Syeda [1 ]
Borse, Vivek [1 ]
Srivastava, Rohit [1 ]
机构
[1] Indian Inst Technol, Dept Biosci & Bioengn, NanoBios Lab, Bombay 400076, Maharashtra, India
[2] SAMEER, Photon Div, IIT Bombay Campus, Bombay 400076, Maharashtra, India
来源
关键词
fluorescence intensity; lateral flow assay; silicon photomultiplier; LATERAL-FLOW IMMUNOASSAY; RAPID DETECTION; ANTIGEN; ASSAY; DIAGNOSIS; SENSITIVITY; OXIDE;
D O I
10.1117/12.2305846
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Fluorescent lateral flow assays (LFA) strips have gained popularity for medical diagnostics application by offering fast and reliable response in both qualitative & quantitative readout formats. The fluorescence emission is generated when excited with appropriate optical source, and is dependent on the analyte concentration in the sample spotted on the LFA strips. Quantitative detection requires a LFA reader to carry out accurate and precise measurements of the fluorescence emission. These readers can be of either benchtop or handheld type, and conventionally use either photo multiplier tube (PMT) or avalanche photodiodes (APD) or customized photo diodes. In addition to their proven benefits like high sensitivity, speed and gain, the availability of silicon photomultipliers (SiPM) in micro form factor makes them good choice for developing miniaturized LFA strip readers. In this study, a portable fluorescence reader using SiPM sensor has been designed, which records the fluorescence intensity of the spot on planar surfaces e.g. nitrocellulose membrane (NCM) packaged in the plastic cases. The design and operation details of the benchtop reader using SiPM sensor along with excitation source, focusing and collimating optics and power supplies integrated with general purpose microcontroller board in a mechanical housing are reported in this paper. The testing of the developed reader is done by using mercaptopropionic acid capped cadmium telluride quantum dots (MPA-CdTe QDs) as the fluorescent analytes spotted on NCM packaged plastic strips. The results obtained from the developed portable reader are compared with the standard fluorescence plate reader for QD concentration varying from 60 mu g/mL to 420 mu g/mL and are found to be in good accordance with the response & resolution of the conventional fluorescent plate reader. Further work is under development for testing the developed reader for disease diagnostic applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Low Intensity Fluorescence Light Measurements Using Silicon Photomultiplier with Dedicated Front-end ASIC
    Baszczyk, M.
    Dorosz, P.
    Glab, S.
    Mik, L.
    Kucewicz, W.
    Pijanowska, D. G.
    Szczypinski, R.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [22] Real-time fluorescence lifetime actuation for cell sorting using a CMOS SPAD silicon photomultiplier
    Della Rocca, Francescopaolo Mattioli
    Nedbal, Jakub
    Tyndall, David
    Krstajic, Nikola
    Li, David Day-Uei
    Ameer-Beg, Simon M.
    Henderson, Robert K.
    OPTICS LETTERS, 2016, 41 (04) : 673 - 676
  • [23] Development of Silicon Photomultiplier sensors using a 180 nm custom CMOS process technology
    Topkar, A.
    Singh, A.
    Aggarwal, B.
    Chakraborty, S.
    Kumar, A.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (03)
  • [24] Design and Development of a Telomere Sensor Based on Fluorescence Energy Transfer
    Li, Haitao
    BIOPHYSICAL JOURNAL, 2016, 110 (03) : 639A - 640A
  • [25] DEVELOPMENT OF ELECTROCHEMICAL SILICON SENSOR .1. DESIGN OF AN ELECTROCHEMICAL SILICON SENSOR INCORPORATING AUXILIARY ELECTRODE
    IWASE, M
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 : 1594 - 1594
  • [26] Design and Development of Low-Cost, Portable, and Smart Chlorophyll-A Sensor
    Chowdhury, Rakibul Islam
    Wahid, Khan Arif
    Nugent, Katy
    Baulch, Helen
    IEEE SENSORS JOURNAL, 2020, 20 (13) : 7362 - 7371
  • [27] Simulation Study on DOI-PET Module Design Using LSO and New Silicon Photomultiplier
    Lee, C. H.
    Cho, G.
    Kim, H. D.
    Jeon, H. S.
    Kang, B. S.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3715 - 3717
  • [28] Compact Fluorescence Sensor using On-chip Silicon Nitride Microdisk
    Ghasemi, Farshid
    Chamanzar, Maysamreza
    Hosseini, Ehsan Shah
    Eftekhar, Ali Asghar
    Li, Qing
    Atabaki, Amir H.
    Adibi, Ali
    2011 IEEE PHOTONICS CONFERENCE (PHO), 2011, : 151 - 152
  • [29] Design, development and characterization of MEMS silicon diaphragm force sensor
    Kumar, Rajesh
    Rab, Shanay
    Pant, B. D.
    Maji, S.
    VACUUM, 2018, 153 : 211 - 216
  • [30] Developing a dual energy x-ray absorptiometry (DEXA) system using SrI2:Eu2+ coupled to silicon photomultiplier (SiPM)
    Matei, Liviu
    Groza, Michael
    Gomez, Michelle
    Espinoza, Kricia Ruano
    Buliga, Vladimir
    Burger, Arnold
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXII, 2020, 11494