Microfluidic platform for integrated plasmonic detection in laminal flow

被引:5
|
作者
Campu, Andreea [1 ,2 ]
Lerouge, Frederic [3 ]
Craciun, Ana-Maria [1 ]
Murariu, Teodora [4 ]
Turcu, Ioan [4 ]
Astilean, Simion [1 ,2 ]
Monica, Focsan [1 ]
机构
[1] Babes Bolyai Univ, Nanobiophoton & Laser Microspectroscopy Ctr, Interdisciplinary Res Inst Bionanosci, Treboniu Laurean 42, Cluj Napoca 400271, Romania
[2] Babes Bolyai Univ, Biomol Phys Dept, Fac Phys, M Kogalniceanu 1, Cluj Napoca 400084, Cluj, Romania
[3] Univ Lyon 1, Ecole Normale Super Lyon, CNRS, UMR 5182,Lab Chim, 46 Allee Italie, F-69364 Lyon 07, France
[4] Natl Inst Res & Dev Isotop & Mol Technol, Donat 67-103, Cluj Napoca 400293, Romania
关键词
microfluidic chip; gold bipyramids; detection in laminal flow; LSPR; SERS; ENHANCED RAMAN-SCATTERING; GOLD NANOBIPYRAMIDS; SURFACE; IMMUNOASSAY; RESONANCE; SERS;
D O I
10.1088/1361-6528/ab8e72
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this work, we propose a novel approach to design robust microfluidic devices with integrated plasmonic transducers allowing portability, reduced analysis time through dynamic measurements and high sensitivity. Specifically, the strategy we apply involves two steps: (i) the controlled deposition of gold bipyramidal nanoparticles (AuBPs) onto a functionalized solid glass substrate and (ii) the integration of the as-fabricated plasmonic substrate into a polydimethylsiloxane (PDMS) microfluidic circuit. The localized surface plasmon resonance (LSPR) sensitivity of the plasmonic-microfluidic device was evaluated by monitoring the optical responses at refractive index changes, proving a bulk sensitivity of 243 nm RIU-1 for the longitudinal LSPR band of isolated AuBPs and 150 nm RIU-1 for the band assigned to end-to-end linked nanoparticles. A strong electric field generated in the gaps between AuBPs-due to the generation of the so-called extrinsic 'hot-spots'-was subsequently proved by the volumetric surface enhanced Raman scattering (SERS) detection of molecules in continuous flow conditions by loading the analyte into the microfluidic channel via a syringe pump. In conclusion, our miniaturized portable microfluidic system aims to detect and identify, in real-time with high accuracy, analyte molecules in laminal flow, thus providing a groundwork for further complex biosensing applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] A microfluidic platform with integrated arrays for immunologic assays for biological pathogen detection
    Klemm, Richard
    Becker, Holger
    Hlawatsch, Nadine
    Julich, Sandra
    Miethe, Peter
    Moche, Christian
    Schattschneider, Sebastian
    Tomaso, Herbert
    Gaertner, Claudia
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XV, 2014, 9073
  • [12] A microfluidic device with integrated fluorimetric detection for flow injection analysis
    Alexandre Fonseca
    Ivo M. Raimundo
    Jarbas J. R. Rohwedder
    Renato S. Lima
    Mário C. Ugulino Araújo
    Analytical and Bioanalytical Chemistry, 2010, 396 : 715 - 723
  • [13] A microfluidic device with integrated fluorimetric detection for flow injection analysis
    Fonseca, Alexandre
    Raimundo, Ivo M., Jr.
    Rohwedder, Jarbas J. R.
    Lima, Renato S.
    Ugulino Araujo, Mario C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (02) : 715 - 723
  • [14] A microfluidic platform with integrated flow sensing for focal chemical stimulation of cells and tissue
    Kuo, Jonathan T. W.
    Chang, Li-Yuan
    Li, Po-Ying
    Hoang, Tuan
    Meng, Ellis
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (02) : 267 - 276
  • [15] Microfluidic-based detection platform for on-the-flow analyte characterization
    Kiesel, Peter
    Beck, Markus
    Johnson, Noble
    Bassler, Michael
    SILICON PHOTONICS V, 2010, 7606
  • [16] Integrated microfluidic platform for oral diagnostics
    Herr, Amy E.
    Hatch, Anson V.
    Giannobile, William V.
    Throckmorton, Daniel J.
    Tran, Huu M.
    Brennan, James S.
    Singh, Anup K.
    ORAL-BASED DIAGNOSTICS, 2007, 1098 : 362 - 374
  • [17] AN INTEGRATED MICROFLUIDIC PLATFORM FOR CHROMOSOMAL ANALYSIS
    Tai, Chien-Hsuan
    Chen, Ya-Lan
    Ho, Chung-Liang
    Lee, Gwo-Bin
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [18] A plasmonic mesoporous gold-based SERS-microfluidic platform for the detection of infectious diseases
    Masud, Mostafa Kamal
    Natsuhara, Daigo
    Dai, Yuchen
    Bashir, Javeria
    Nugraha, Asep Sugih
    Alshehri, Saad M.
    Bando, Yoshio
    Hossain, Md. Shahriar
    Kaneti, Yusuf Valentino
    Shibata, Takayuki
    Yamauchi, Yusuke
    JOURNAL OF MATERIALS CHEMISTRY C, 2024, 12 (44) : 17977 - 17985
  • [19] Multiplex Viral Detection Platform Based on a Aptamers-Integrated Microfluidic Channel
    Saraf, Nileshi
    Villegas, Michael
    Willenberg, Bradley Jay
    Seal, Sudipta
    ACS OMEGA, 2019, 4 (01): : 2234 - 2240
  • [20] MICROFLUIDIC ELECTROCHEMILUMINESCENCE (ECL) INTEGRATED FLOW CELL FOR PORTABLE FLUORESCENCE DETECTION
    Tsuwaki, Miho
    Mizuno, Jun
    Kasahara, Takashi
    Edura, Tomohiko
    Kunisawa, Eri
    Ishimatsu, Ryoichi
    Matsunami, Shigeyuki
    Imato, Toshihiko
    Adachi, Chihaya
    Shoji, Shuichi
    2014 IEEE 27TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2014, : 108 - 111