Feasibility study of using polyacrylamide gel dosimeter as brain equivalent material in therapeutic energy range of X-rays

被引:1
|
作者
Khandan, L. Teimoori [1 ]
Kashian, S. [2 ]
Rezaeian, P. [2 ]
机构
[1] Islamic Azad Univ, Fac Sci, Dept Phys, Hamedan Branch, Mousivand Blvd,POB 6518115743, Hamadan, Hamadan, Iran
[2] AEOI, NSTRI, Radiat Applicat Res Sch, North Kargar St,POB 1439951113, Tehran, Iran
关键词
Algorithms and Software for radiotherapy; Dosimetry concepts and apparatus; Instrumentation for gamma-electron therapy; RADIATION-DOSE DISTRIBUTIONS; MONTE-CARLO EVALUATION; NECK PHANTOM; ACUROS XB; HEAD; VERIFICATION; RADIOTHERAPY;
D O I
10.1088/1748-0221/15/03/P03016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper the feasibility study of using polyacrylamide gels as a brain equivalent material has been performed. Thus, the parameters of mass energy absorption coefficient (mu(en)/rho), mass stopping power (S/rho), effective atomic number (Z(eff)), mass attenuation coefficient (mu(eff/)/rho) and absorbed dose delivered to polyacrylamide gel (D) were determined for this gel using analytical and Monte Carlo methods and were compared with brain reference material. The calculation results reveal that the relative difference between the calculated mu(en)/rho, S/rho, Z(eff), mu(eff)/rho and D for polyacrylamide gel and those for brain are 1.32%, less than 1%, less than 2%, less than 4% and less than 1%, respectively in therapeutic energy range. Consequently, like water, polyacrylamide gel can be also used for designing and construction of head and neck phantoms applied for validation of medical algorithms used in treatment planning systems. The advantage of using polyacrylamide gel as a brain equivalent material in comparison to water is that this gel is a reliable X and gamma rays dosimeter applicable for three dimensional dose distribution determination. Also, other advantages of this gel are its low price, availability and forming it in different sizes and shapes. These properties of the polyacrylamide gel make it beneficial as brain equivalent material in designing and construction of head and neck phantoms.
引用
收藏
页数:13
相关论文
共 36 条
  • [1] Feasibility study of a photochromic diarylethene film as a clinical dosimeter for kV X-rays
    Tamura, Mikoto
    Monzen, Hajime
    Matsumoto, Kenji
    Otsuka, Masakazu
    Nishimura, Yasumasa
    RADIATION MEASUREMENTS, 2021, 145
  • [2] CALORIMETER DESIGN, CALIBRATION, AND MEASUREMENTS OF ENERGY DEPENDENCE OF LIF DOSIMETER IN ENERGY RANGE 5-15 KEV OF X-RAYS
    PARASKEV.P
    AGUIAR, JE
    MARTINEZ, P
    HEALTH PHYSICS, 1970, 19 (02): : 355 - +
  • [3] MONOCHROMATIC COMPUTED-TOMOGRAPHY OF THE HUMAN BRAIN USING SYNCHROTRON X-RAYS - TECHNICAL FEASIBILITY
    NACHALIEL, E
    DILMANIAN, FA
    GARRETT, RF
    THOMLINSON, WC
    CHAPMAN, LD
    GMUR, NF
    LAZARZ, NM
    MOULIN, HR
    RIVERS, ML
    RARBACK, H
    STEFAN, PM
    SPANNE, P
    LUKE, PN
    PEHL, R
    THOMPSON, AC
    MILLER, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 319 (1-3): : 305 - 310
  • [4] Feasibility study of the high frequency X-ray communication using selective characteristic X-rays
    Jin, Limin
    Jia, Wenbao
    Hei, Daqian
    Zhao, Lei
    Cheng, Can
    OPTICS COMMUNICATIONS, 2021, 484
  • [5] Experimental Demonstration of Dose Enhancement Due to Gold Nanoparticles and Kilovoltage X-Rays Using Radio-Sensitive Polymer Gel Dosimeter
    Siddiqi, A.
    Yang, Y.
    Dextraze, K.
    Hu, T.
    Krishnan, S.
    Cho, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [6] Study of a gel dosimeter based on Ag nanoparticles for applications in radiation therapy with synchrotron X-rays at ultrahigh dose rate compared to 60Co γ-rays
    Soliman, Yasser S.
    Capron, Marie
    Pontoni, Diego
    Krisch, Michael
    Pellicioli, Paolo
    RADIATION PHYSICS AND CHEMISTRY, 2025, 227
  • [7] Detection and quantification of coronary calcium from dual energy chest x-rays: Phantom feasibility study
    Zhou, Bo
    Wen, Di
    Nye, Katelyn
    Gilkeson, Robert C.
    Eck, Brendan
    Jordan, David
    Wilson, David L.
    MEDICAL PHYSICS, 2017, 44 (10) : 5106 - 5119
  • [8] Feasibility study of deep-learning-based bone suppression incorporated with single-energy material decomposition technique in chest X-rays
    Lim, Younghwan
    Lee, Minjae
    Cho, Hyosung
    Kim, Guna
    Choi, Jaegu
    Cha, Bokyung
    Kim, Sunkwon
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1139):
  • [9] Experimental study for the feasibility of using hard x-rays for micro-XRF analysis of multilayered metals
    Polese, C.
    Dabagov, S. B.
    Esposito, A.
    Hampai, D.
    Gorghinian, A.
    Liedl, A.
    Ferretti, M.
    AIP ADVANCES, 2014, 4 (07):
  • [10] Subject-specific body segment parameters' estimation using biplanar X-rays: a feasibility study
    Sandoz, Baptiste
    Laporte, Sebastien
    Skalli, Wafa
    Mitton, David
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (06) : 649 - 654