Study of a gel dosimeter based on Ag nanoparticles for applications in radiation therapy with synchrotron X-rays at ultrahigh dose rate compared to 60Co γ-rays

被引:0
|
作者
Soliman, Yasser S. [1 ]
Capron, Marie [3 ]
Pontoni, Diego [3 ]
Krisch, Michael [2 ]
Pellicioli, Paolo [2 ,4 ]
机构
[1] Egyptian Atom Energy Author AEA, Natl Ctr Radiat Res & Technol NCRRT, POB 8029, Cairo 11787, Egypt
[2] ESRF European Synchrotron, ID17 Biomed Beamline,71 Ave Martyrs, F-38000 Grenoble, France
[3] ESRF European Synchrotron, Partnership Soft Condensed Matter PSCM, 71 Ave Martyrs, F-38000 Grenoble, France
[4] Univ Bern, Inst Anat, Baltzerstr 2, CH-3012 Bern, Switzerland
关键词
Gel dosimeter; Ag nanoparticles; Dosimetry; X-ray synchrotron radiation; Radiotherapy; SILVER NANOPARTICLES; QUALITY-ASSURANCE; GOLD NANOPARTICLES; OPTICAL-PROPERTIES; ALANINE DOSIMETER; MEDICAL BEAMLINE; FILM DOSIMETRY; MICROBEAM; RADIOTHERAPY; GELATIN;
D O I
10.1016/j.radphyschem.2024.112351
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A silver nitrate (AgNO3) gel was developed and evaluated as a dosimeter for synchrotron X-ray-based studies in microbeam radiation therapy (MRT) and FLASH radiation therapy. The gel was irradiated at the European Synchrotron Radiation Facility (ID17 Biomedical beamline) with a continuous X-ray spectrum in the 50-600 key range and a dose rate of 11.6 kGy/s. The spectrophotometric response after irradiation at this beamline was compared with the response at a conventional 60Co gamma-ray source providing a dose rate of 0.27 Gy/s. Ag + ions in the gel dosimeter undergo reduction to Ago nanoparticles, as detected at 450 nm, which is a surface plasmon resonance band. The intensity of this band increased linearly with increasing absorbed dose up to 100 Gy, and improved with the addition of glycerol. The gel dosimeter exhibited the lowest detectable dose (LDD) of 75.9% lower and a dose deposition of 76% higher for ID17 beamline irradiation than for 60Co irradiation. The theoretical relative response HQ,Qo for the gel irradiated at the synchrotron was 1.70, which is in close agreement with the experimental relative response FQ,Qo = 1.76. These results confirm the dose enhancement in the gel irradiated with orthovoltage X-rays. The good properties of the silver nitrate gel, together with its increased sensitivity to orthovoltage X-ray irradiation and modest overall uncertainty of 5.8% (2 sigma), confirm that the gel is a valid dosimeter for measurements at ultrahigh dose rates for synchrotron radiotherapy. The dosimeter is also a promising candidate for dose enhancement factor measurements in nanoparticle-based radiotherapy techniques.
引用
收藏
页数:11
相关论文
共 19 条
  • [1] Comparison of the dosimetric response of two Sr salts irradiated with 60Co?-rays and synchrotron X-rays at ultra-high dose rate
    Soliman, Yasser S.
    Fahim, Ramy Amer
    Pellicioli, Paolo
    Krisch, Michael
    Beshir, W. B.
    Abdel-Fattah, A. A.
    El-Moghny, Muhammad G. Abd
    El-Deab, Mohamed S.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [2] Characterization of ferrous-agarose-xylenol gel dosimeter at 60Co γ-rays beam therapy unit
    Moussous, Ouiza
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (01) : 105 - 112
  • [3] Characterization of ferrous-agarose-xylenol gel dosimeter at 60Co γ-rays beam therapy unit
    Ouiza Moussous
    Radiological Physics and Technology, 2021, 14 : 105 - 112
  • [4] Comparison of dicentric dose response curves of 6 MV LINAC X-rays and 60Co γ-rays for biodosimetry application
    Kumar, A. Arul Anantha
    Bakkiam, D.
    Sonwani, Swetha
    Seenisamy, R.
    Sivasubramanian, K.
    Venkatraman, B.
    APPLIED RADIATION AND ISOTOPES, 2017, 129 : 124 - 129
  • [5] Response of the alanine/ESR dosimetry system to MV x-rays relative to 60Co radiation
    Anton, Mathias
    Kapsch, Ralf-Peter
    Krystek, Michael
    Renner, Franziska
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10): : 2753 - 2770
  • [6] Experimental Demonstration of Dose Enhancement Due to Gold Nanoparticles and Kilovoltage X-Rays Using Radio-Sensitive Polymer Gel Dosimeter
    Siddiqi, A.
    Yang, Y.
    Dextraze, K.
    Hu, T.
    Krishnan, S.
    Cho, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [7] Comparison of ionizing radiation damage in NMOSFET device from different radiation resources and different dose rate 60Co gamma rays
    He, Bao-Ping
    Wang, Gui-Zhen
    Zhou, Hui
    Luo, Yin-Hong
    Jiang, Jing-He
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2002, 30 (08): : 1229 - 1231
  • [8] Development of a compact linear accelerator to generate ultrahigh dose rate high-energy X-rays for FLASH radiotherapy applications
    Liu, Focheng
    Shi, Jiaru
    Zha, Hao
    Li, Guohua
    Li, An
    Gu, Weihang
    Hu, Ankang
    Gao, Qiang
    Wang, Haokun
    Zhang, Liang
    Liu, Jinsheng
    Liu, Yaohong
    Xu, Huijun
    Tang, Chuanxiang
    Chen, Huaibi
    MEDICAL PHYSICS, 2023, 50 (03) : 1680 - 1698
  • [9] Measurement of the peripheral dose for the tangential breast treatment technique with Co-60 gamma radiation and high energy X-rays
    VanderGiessen, PH
    RADIOTHERAPY AND ONCOLOGY, 1997, 42 (03) : 257 - 264
  • [10] New standards of absorbed dose to water under reference conditions by graphite calorimetry for 60Co and high-energy x-rays at LNE-LNHB
    Delaunay, F.
    Gouriou, J.
    Daures, J.
    Le Roy, M.
    Ostrowsky, A.
    Rapp, B.
    Sorel, S.