Feasibility study of using polyacrylamide gel dosimeter as brain equivalent material in therapeutic energy range of X-rays

被引:1
|
作者
Khandan, L. Teimoori [1 ]
Kashian, S. [2 ]
Rezaeian, P. [2 ]
机构
[1] Islamic Azad Univ, Fac Sci, Dept Phys, Hamedan Branch, Mousivand Blvd,POB 6518115743, Hamadan, Hamadan, Iran
[2] AEOI, NSTRI, Radiat Applicat Res Sch, North Kargar St,POB 1439951113, Tehran, Iran
关键词
Algorithms and Software for radiotherapy; Dosimetry concepts and apparatus; Instrumentation for gamma-electron therapy; RADIATION-DOSE DISTRIBUTIONS; MONTE-CARLO EVALUATION; NECK PHANTOM; ACUROS XB; HEAD; VERIFICATION; RADIOTHERAPY;
D O I
10.1088/1748-0221/15/03/P03016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper the feasibility study of using polyacrylamide gels as a brain equivalent material has been performed. Thus, the parameters of mass energy absorption coefficient (mu(en)/rho), mass stopping power (S/rho), effective atomic number (Z(eff)), mass attenuation coefficient (mu(eff/)/rho) and absorbed dose delivered to polyacrylamide gel (D) were determined for this gel using analytical and Monte Carlo methods and were compared with brain reference material. The calculation results reveal that the relative difference between the calculated mu(en)/rho, S/rho, Z(eff), mu(eff)/rho and D for polyacrylamide gel and those for brain are 1.32%, less than 1%, less than 2%, less than 4% and less than 1%, respectively in therapeutic energy range. Consequently, like water, polyacrylamide gel can be also used for designing and construction of head and neck phantoms applied for validation of medical algorithms used in treatment planning systems. The advantage of using polyacrylamide gel as a brain equivalent material in comparison to water is that this gel is a reliable X and gamma rays dosimeter applicable for three dimensional dose distribution determination. Also, other advantages of this gel are its low price, availability and forming it in different sizes and shapes. These properties of the polyacrylamide gel make it beneficial as brain equivalent material in designing and construction of head and neck phantoms.
引用
收藏
页数:13
相关论文
共 36 条
  • [21] Feasible Study on Energy Subtraction X-ray CT Technique Using Comb-shape Filtered X-rays
    Tsubouchi, Tashiro
    Watanabe, Kenichi
    Yamazaki, Atsushi
    Uritani, Akira
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 271 - 274
  • [22] Stress Measurements of Quasi-Coarse Grained Material using Double Exposure Method with High-Energy Monochromatic X-Rays
    Suzuki, Kenji
    Yamada, Minami
    Shiro, Ayumi
    Shobu, Takahisa
    Toyokawa, Hidenori
    Saji, Choji
    Zairyo/Journal of the Society of Materials Science, Japan, 2022, 71 (04): : 347 - 353
  • [23] Study of the electrode material and insulator length effect on high-energy X-rays emitted by a 4-kJ plasma focus device
    M. Habibi
    Plasma Physics Reports, 2012, 38 : 566 - 573
  • [25] Microscopic estimation of tumor dose enhancement during gold nanoparticle-aided radiation therapy (GNRT) using diagnostic energy range x-rays
    Cho, S.
    Vassiliev, O.
    Krishnan, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2468 - 2469
  • [26] A comprehensive Monte Carlo study to design a novel multi-nanoparticle loaded nanocomposites for augmentation of attenuation coefficient in the energy range of diagnostic X-rays
    Sayyadi, Elahe
    Mesbahi, Asghar
    Zamiri, Reza Eghdam
    Nejad, Farshad Seyyed
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (04): : 279 - 289
  • [27] Ultrahigh-pressure measurement in the multimegabar range by energy-domain synchrotron radiation 57Fe-Mossbauer spectroscopy using focused X-rays
    Mitsui, Takaya
    Seto, Makoto
    Hirao, Naohisa
    Ohishi, Yasuo
    Kobayashi, Yasuhiro
    Higashitaniguchi, Satoshi
    Masuda, Ryo
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2007, 46 (12-16): : L382 - L384
  • [28] A comparative study of the retrogradation kinetics of gelatinized wheat starch in gel and powder form using X-rays, differential scanning calorimetry and dynamic mechanical analysis
    Roulet, Ph.
    MacInnes, W. M.
    Wuersch, P.
    Sanchez, R. M.
    Raemy, A.
    FOOD HYDROCOLLOIDS, 1988, 2 (05) : 381 - 396
  • [29] VARIATION OF ENERGY LINEARITY AND W-VALUE IN GASEOUS XENON RADIATION DETECTORS FOR X-RAYS IN THE 0.1 TO 25 KEV ENERGY-RANGE - A MONTE-CARLO SIMULATION STUDY
    SANTOS, FP
    DIAS, THVT
    STAUFFER, AD
    CONDE, CAN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (2-3): : 347 - 352
  • [30] Get 73-2022 Special State Primary Standard of the Absorbed Dose and Absorbed Dose Rate to Tissue-Equivalent Material of X-Rays with a Limiting Photon Energy of 10–60 keV
    A. Yu. Villevalde
    A. V. Oborin
    Measurement Techniques, 2022, 65 : 471 - 476