Ergonomic port placement in robotic colorectal surgery

被引:5
|
作者
Wong, Shing Wai [1 ,2 ]
Ang, Zhen Hao [1 ,2 ]
Chua, Jia Lin [3 ]
Crowe, Philip [1 ,2 ]
机构
[1] Prince Wales Hosp, Dept Gen Surg, Sydney, NSW, Australia
[2] Univ New South Wales, Prince Wales Clin Sch, Sydney, NSW, Australia
[3] Westmead Hosp, Dept Radiol, Sydney, NSW, Australia
关键词
ergonomics; port placement; robotic colorectal surgery; MANIPULATION ANGLE;
D O I
10.1111/codi.15804
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Aim The aim of the study was to determine how spacing between ports and alignment of ports (oblique or vertical) influences manipulation angles in robotic colorectal surgery. Method Abdominal CT scans of 10 consecutive robotic right hemicolectomy and 10 consecutive robotic high anterior resection patients were analysed. The manipulation angles were calculated using fixed points on the preoperative abdominal coronal CT scan. Port placements were marked on the CT scan. The fixed points used to measure the manipulation angles were from the most lateral part of the caecum, hepatic flexure, splenic flexure, the descending colon/sigmoid colon junction and the sigmoid colon/rectum junction. Results For right hemicolectomy and high anterior resection surgery, a port spacing of 8 cm compared with 6 cm resulted in greater manipulation angles. With 6-cm port spacing, wider manipulation angles were not achieved with vertical port alignment compared with oblique alignment except for dissection at the splenic flexure. Conclusions The greatest manipulation angles were achieved with the oblique 8-cm port spacing, which should be used in most cases.
引用
收藏
页码:2593 / 2603
页数:11
相关论文
共 50 条
  • [11] Is robotic surgery truly ergonomic for the surgeon?
    Elhage, O.
    Shortland, A. P.
    Challacombe, B. J.
    Murphy, D.
    Sahai, A.
    Dasgupta, P.
    JOURNAL OF ENDOUROLOGY, 2006, 20 : A225 - A225
  • [12] ANGLING FOR AN ERGONOMIC APPROACH TO ROBOTIC SURGERY
    Rao, A. R.
    Gray, R.
    Mayer, E.
    Collins, J.
    Motiwala, H.
    Laniado, M.
    Karim, O.
    BJU INTERNATIONAL, 2012, 110 : 134 - 135
  • [13] Optimizing robotic renal surgery: A novel port placement technique and current results
    Badani, Ketan K.
    Humo, Michael
    Muhletaler, Fred
    JOURNAL OF UROLOGY, 2007, 177 (04): : 236 - 237
  • [14] Ergonomic hand positioning overcomes visual perception mismatch in nonsimulated robotic colorectal surgery
    Wong, Shing Wai
    Lim, Ranah
    Wong, Xiuling Jasmine
    Crowe, Philip
    JOURNAL OF SURGICAL CASE REPORTS, 2024, 2024 (03):
  • [15] Optimizing robotic placement renal surgery: The lateral camera port technique and current results
    Badani, Ketan K.
    Muhletaler, Fred
    Fumo, Michael
    Kaul, Sanjeev
    Peabody, James O.
    Bhandari, Mahendra
    Menon, Mani
    JOURNAL OF ENDOUROLOGY, 2008, 22 (03) : 507 - 510
  • [16] Variance in Abdominal Wall Anatomy and Port Placement in Women Undergoing Robotic Gynecologic Surgery
    Matthews, Catherine A.
    Schubert, Christine M.
    Woodward, Ashley P.
    Gill, Edward J.
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2010, 17 (05) : 583 - 586
  • [17] A user-friendly automated port placement planning system for laparoscopic robotic surgery
    Torres, Luis G.
    Azimian, Hamidreza
    Enquobahrie, Andinet
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [18] Hidden incision endoscopic surgery (HIdES) trocar placement for pediatric robotic pyeloplasty: comparison to traditional port placement
    Hong Y.H.
    DeFoor W.R., Jr.
    Reddy P.P.
    Schulte M.
    Minevich E.A.
    VanderBrink B.A.
    Noh P.H.
    Journal of Robotic Surgery, 2018, 12 (1) : 43 - 47
  • [19] Robotic Colorectal Surgery
    Baik, Seung Hyuk
    YONSEI MEDICAL JOURNAL, 2008, 49 (06) : 891 - 896
  • [20] Robotic colorectal surgery
    Eldin M.G.
    Gorgun E.
    Current Surgery Reports, 4 (6)